Key specifications

Key specifications
Flow rate range1–200 mL/min
Maximum operating pressure20 bar (300 psi)
UV detector range200–400 nm (DAD)
ELSD drift tube temperature30–80 °C
ELSD nebulizer gasNitrogen, 2–4 L/min
ELSD detection limit≈10–50 ng on column
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, ATEX 2014/34/EU, ISO 9001

What is the Flash Chromatography System with UV and ELSD Detection?

A flash chromatography system with UV and ELSD detection adds an evaporative light scattering detector to the UV detector, so compounds without chromophores are detected as well. It is chosen for natural products, carbohydrates, lipids, terpenoids and polymers that cannot be tracked by UV absorption alone.

What is the Flash Chromatography System with UV and ELSD Detection?

A flash chromatography system with UV and ELSD detection adds an evaporative light scattering detector to the UV detector, so compounds without chromophores are detected as well. It is chosen for natural products, carbohydrates, lipids, terpenoids and polymers that cannot be tracked by UV absorption alone.

Overview

An ELSD nebulizes a split portion of column effluent with nitrogen or air, evaporates the mobile phase in a heated drift tube at 30–80 °C, and measures light scattered by the remaining non-volatile particles. Response depends on mass rather than structure, which suits sugars, triterpenoids, fatty acids and surfactants. In flash systems, a splitter diverts about 0.5–2% of flow to the ELSD, with a make-up solvent line so that signal is delayed minimally, and the main stream goes to the fraction collector. UV and ELSD signals are displayed together, and fraction triggering can use either or both. ELSD response is non-linear and less sensitive than UV, with a detection limit of roughly 10–50 ng on column, and it requires volatile mobile phases without non-volatile buffers. Nitrogen supply, typically 2–4 L/min, and periodic drift-tube cleaning are operating considerations.

How does it work?

Flash chromatography forces solvent through a packed cartridge at moderate pressure, typically 1–20 bar, instead of relying on gravity. Cartridges contain 4 g to over 1 kg of irregular or spherical silica of 20–60 µm, or bonded phases such as C18, amino and cyano. A binary pump blends two solvents, for example hexane and ethyl acetate for normal phase or water and acetonitrile for reversed phase, into linear or step gradients. Dissolved or dry-loaded samples are applied at the column head, and compounds elute according to polarity. A UV or diode-array detector monitors 200–400 nm, and an evaporative light scattering detector (ELSD) detects compounds lacking a chromophore. A fraction collector triggers by threshold or slope and deposits fractions into tubes or flasks, with software showing a real-time chromatogram. Elution can be compared to TLC Rf values to predict gradients.

What are the key features?

  • Evaporative light scattering detector with heated drift tube at 30–80 °C
  • Flow splitter sending 0.5–2% of effluent to ELSD with make-up solvent pump
  • Simultaneous UV and ELSD chromatograms with independent or combined fraction triggering
  • Detection of sugars, lipids, terpenoids and polymers lacking UV chromophores
  • Nitrogen generator compatibility supplying 2–4 L/min to the nebulizer

What are the technical specifications?

A typical flash chromatography system with uv and elsd detection configuration offers flow rate range of 1–200 mL/min, maximum operating pressure of 20 bar (300 psi), UV detector range of 200–400 nm (DAD), ELSD drift tube temperature of 30–80 °C, ELSD nebulizer gas of Nitrogen, 2–4 L/min and ELSD detection limit of ≈10–50 ng on column. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Flash Chromatography System with UV and ELSD Detection is used in natural product saponin and terpenoid isolation, carbohydrate and glycoside purification, lipid and surfactant fractionation, polymer oligomer cleanup and compounds with weak UV absorption. Across the wider Flash Chromatography class, laboratories also deploy it for purification of synthetic reaction products, isolation of natural product fractions and purification of pharmaceutical intermediates.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, ATEX 2014/34/EU, ISO 9001, USP <621>, ICH Q3C, EN 60079-0, GB/T 15481 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and ATEX compliance for solvent area; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install in a fume hood or ventilated enclosure because normal-phase solvents such as hexane, ethyl acetate and dichloromethane are flammable or hazardous, and keep ignition sources away. Use grounded tubing and containers to avoid static buildup. Flush lines with compatible solvent before changing between normal and reversed phase, using miscible intermediates such as isopropanol. Inspect pump seals, check valves and cartridge holders regularly, and do not exceed cartridge pressure ratings, often 10–20 bar. Calibrate detector baselines with blank gradients and replace UV lamps as recommended. Dispose of solvent waste and used silica following local regulations. Flash systems are not normally subject to GMP qualification, but record methods and audit results for traceability.

How do I select the right Flash Chromatography System with UV and ELSD Detection?

Select UV plus ELSD when a significant share of your targets lack chromophores. The ELSD adds cost and needs nitrogen, so UV-only systems are better for UV-active products. In an RFQ specify splitter design, ELSD sensitivity, gas supply, gradient range and collector capacity, and confirm that mobile phase additives are volatile.

How does it compare with other Flash Chromatography variants?

Choose by scale, detection and phase. Cartridge size determines loading: roughly 1–10% of silica mass for easy separations, so a 40 g cartridge handles 0.4–4 g of crude. Systems with UV only suit chromophoric compounds, while adding ELSD or a mass detector is required for sugars, lipids and many natural products. Reversed-phase capable systems need pumps and seals compatible with water and higher backpressure, up to 20 bar or more. Consider maximum flow rate, typically 100–300 mL/min for mid-scale and up to 1000 mL/min for kilogram-scale work, and the number of fractions and tube sizes for the collector. Solvent safety matters, so check ATEX-rated designs, closed fraction bays and waste management. Software features such as TLC-to-gradient conversion and method libraries speed routine purification.

Full specifications

Full specifications
Flow rate range1–200 mL/min
Maximum operating pressure20 bar (300 psi)
UV detector range200–400 nm (DAD)
ELSD drift tube temperature30–80 °C
ELSD nebulizer gasNitrogen, 2–4 L/min
ELSD detection limit≈10–50 ng on column
Flow split ratio to ELSD0.5–2%
Cartridge size range4–330 g
Fraction collector capacity100–400 tubes
Mobile phase requirementVolatile solvents and additives only

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Natural product saponin and terpenoid isolation
  • Carbohydrate and glycoside purification
  • Lipid and surfactant fractionation
  • Polymer oligomer cleanup
  • Compounds with weak UV absorption

Key features

  • Evaporative light scattering detector with heated drift tube at 30–80 °C
  • Flow splitter sending 0.5–2% of effluent to ELSD with make-up solvent pump
  • Simultaneous UV and ELSD chromatograms with independent or combined fraction triggering
  • Detection of sugars, lipids, terpenoids and polymers lacking UV chromophores
  • Nitrogen generator compatibility supplying 2–4 L/min to the nebulizer

Frequently asked questions about Flash Chromatography System with UV and ELSD Detection

ELSD evaporates and consumes the sample that passes through it. Flash systems therefore use a splitter that sends only about 0.5–2% of flow to the ELSD while the rest goes to the fraction collector, so product recovery is essentially unaffected.

Request a quotation for the Flash Chromatography System with UV and ELSD Detection

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote