Gradient Flash Chromatography System with UV Detection — product photo

Gradient Flash Chromatography System with UV Detection

梯度快速制备色谱系统(UV 检测)

  • SKU FLC-0002
  • Flash Chromatography
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • ATEX compliance for solvent area (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Flow rate range1–200 mL/min
Maximum operating pressure20 bar (300 psi)
Solvent channels2 (binary), optional 4
Gradient accuracy±2% absolute
Detector wavelength range200–400 nm (DAD), 200–800 nm (UV-Vis)
Cartridge size range4–330 g silica
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, ATEX 2014/34/EU, ISO 9001

What is the Gradient Flash Chromatography System with UV Detection?

A gradient flash chromatography system with UV detection blends two solvents through a binary pump and monitors 200–400 nm with a diode-array or variable UV detector. It is the standard automated configuration for synthetic chemistry laboratories purifying chromophoric products, using programmable gradients that separate closely eluting compounds.

What is the Gradient Flash Chromatography System with UV Detection?

A gradient flash chromatography system with UV detection blends two solvents through a binary pump and monitors 200–400 nm with a diode-array or variable UV detector. It is the standard automated configuration for synthetic chemistry laboratories purifying chromophoric products, using programmable gradients that separate closely eluting compounds.

Overview

The gradient system includes a binary high-pressure or low-pressure mixing pump delivering 1–200 mL/min at up to 20 bar, a UV or UV-Vis detector with multi-wavelength monitoring, and a fraction collector with 100–400 tube capacity. Users select linear, step or focused gradients, and software can convert a TLC Rf value into an initial gradient, reducing method development time. Dry-load cartridges and liquid injection ports accommodate poorly soluble crudes. Cartridges from 4 g to 330 g are supported, covering 50 mg to about 30 g of crude material. Peak-based and threshold-based fraction collection minimizes the number of tubes and solvent usage. Real-time chromatograms, run history and method libraries improve reproducibility. Normal-phase silica is typical, but the same hardware can run amino, cyano or diol cartridges. For compounds without chromophores, a system with ELSD is more appropriate.

How does it work?

Flash chromatography forces solvent through a packed cartridge at moderate pressure, typically 1–20 bar, instead of relying on gravity. Cartridges contain 4 g to over 1 kg of irregular or spherical silica of 20–60 µm, or bonded phases such as C18, amino and cyano. A binary pump blends two solvents, for example hexane and ethyl acetate for normal phase or water and acetonitrile for reversed phase, into linear or step gradients. Dissolved or dry-loaded samples are applied at the column head, and compounds elute according to polarity. A UV or diode-array detector monitors 200–400 nm, and an evaporative light scattering detector (ELSD) detects compounds lacking a chromophore. A fraction collector triggers by threshold or slope and deposits fractions into tubes or flasks, with software showing a real-time chromatogram. Elution can be compared to TLC Rf values to predict gradients.

What are the key features?

  • Binary pump delivering 1–200 mL/min with linear, step and focused gradient programming
  • UV or diode-array detector monitoring 200–400 nm with simultaneous two-wavelength collection
  • Software conversion of TLC Rf values into recommended starting gradients
  • Support for cartridges from 4 g to 330 g and solid-load cartridges for poorly soluble samples
  • Peak- and slope-based fraction collection minimizing tubes, solvent use and time

What are the technical specifications?

A typical gradient flash chromatography system with uv detection configuration offers flow rate range of 1–200 mL/min, maximum operating pressure of 20 bar (300 psi), solvent channels of 2 (binary), optional 4, gradient accuracy of ±2% absolute, detector wavelength range of 200–400 nm (DAD), 200–800 nm (UV-Vis) and cartridge size range of 4–330 g silica. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Gradient Flash Chromatography System with UV Detection is used in purification of drug discovery intermediates, synthetic reaction product isolation, library compound cleanup, impurity isolation for structural characterization and routine process development samples. Across the wider Flash Chromatography class, laboratories also deploy it for purification of synthetic reaction products, isolation of natural product fractions and purification of pharmaceutical intermediates.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, ATEX 2014/34/EU, ISO 9001, USP <621>, ICH Q3C, EN 60079-0, GB/T 15481 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and ATEX compliance for solvent area; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install in a fume hood or ventilated enclosure because normal-phase solvents such as hexane, ethyl acetate and dichloromethane are flammable or hazardous, and keep ignition sources away. Use grounded tubing and containers to avoid static buildup. Flush lines with compatible solvent before changing between normal and reversed phase, using miscible intermediates such as isopropanol. Inspect pump seals, check valves and cartridge holders regularly, and do not exceed cartridge pressure ratings, often 10–20 bar. Calibrate detector baselines with blank gradients and replace UV lamps as recommended. Dispose of solvent waste and used silica following local regulations. Flash systems are not normally subject to GMP qualification, but record methods and audit results for traceability.

How do I select the right Gradient Flash Chromatography System with UV Detection?

Select the UV gradient model for most synthetic purification where products absorb UV. Add ELSD if you work with non-chromophoric compounds, or reversed-phase capability if polar compounds dominate. In an RFQ specify maximum cartridge size, gradient channels, wavelength range, fraction collector capacity, TLC conversion software and solvent safety requirements.

How does it compare with other Flash Chromatography variants?

Choose by scale, detection and phase. Cartridge size determines loading: roughly 1–10% of silica mass for easy separations, so a 40 g cartridge handles 0.4–4 g of crude. Systems with UV only suit chromophoric compounds, while adding ELSD or a mass detector is required for sugars, lipids and many natural products. Reversed-phase capable systems need pumps and seals compatible with water and higher backpressure, up to 20 bar or more. Consider maximum flow rate, typically 100–300 mL/min for mid-scale and up to 1000 mL/min for kilogram-scale work, and the number of fractions and tube sizes for the collector. Solvent safety matters, so check ATEX-rated designs, closed fraction bays and waste management. Software features such as TLC-to-gradient conversion and method libraries speed routine purification.

Full specifications

Full specifications
Flow rate range1–200 mL/min
Maximum operating pressure20 bar (300 psi)
Solvent channels2 (binary), optional 4
Gradient accuracy±2% absolute
Detector wavelength range200–400 nm (DAD), 200–800 nm (UV-Vis)
Cartridge size range4–330 g silica
Fraction collector capacity100–400 tubes
Tube size13–30 mm, flasks up to 500 mL
Crude loading range50 mg–30 g
Solvent compatibilityHexane, EtOAc, DCM, MeOH, acetone

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Purification of drug discovery intermediates
  • Synthetic reaction product isolation
  • Library compound cleanup
  • Impurity isolation for structural characterization
  • Routine process development samples

Key features

  • Binary pump delivering 1–200 mL/min with linear, step and focused gradient programming
  • UV or diode-array detector monitoring 200–400 nm with simultaneous two-wavelength collection
  • Software conversion of TLC Rf values into recommended starting gradients
  • Support for cartridges from 4 g to 330 g and solid-load cartridges for poorly soluble samples
  • Peak- and slope-based fraction collection minimizing tubes, solvent use and time

Frequently asked questions about Gradient Flash Chromatography System with UV Detection

A focused gradient holds low solvent strength until near the expected elution point, then ramps to elute the target in a narrow window. It improves resolution between close peaks and saves solvent compared with a long linear gradient across the full range.

Request a quotation for the Gradient Flash Chromatography System with UV Detection

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote