Compact Flame AAS for Teaching and Field Laboratories

教学与现场用紧凑型火焰原子吸收光谱仪

  • SKU FLA-0006
  • Flame AAS
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range190–800 nm
Optical systemcompact single-beam
Spectral bandwidthfixed, 0.7 nm typical
Lamp positions1 or 2, manual change
Flame typeair-acetylene
Detection limit0.005–0.2 mg/L typical
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals

What is the Compact Flame AAS for Teaching and Field Laboratories?

This compact flame AAS trades maximum automation for small size, low cost and simple operation. It is chosen for teaching laboratories, mobile units and small facilities that measure a limited set of elements.

What is the Compact Flame AAS for Teaching and Field Laboratories?

This compact flame AAS trades maximum automation for small size, low cost and simple operation. It is chosen for teaching laboratories, mobile units and small facilities that measure a limited set of elements.

Overview

This variant uses a short optical bench, a single fixed or manually changed lamp position and manual or semi-automatic gas control to reduce footprint and price. It generally covers a reduced wavelength range with fixed bandwidth and may omit advanced background correction, applying simple deuterium or no correction depending on the method. Sample introduction is manual or uses a small basic sampler with far fewer positions. Setup is quick, and the lower gas and power demand makes the instrument suitable for teaching benches and mobile laboratories. The trade-off is lower throughput, limited automation and more operator skill needed to achieve good precision. It remains appropriate for metals at milligram per litre levels in water, soil extracts and beverages, and for demonstrating the principles of atomic absorption in education.

How does it work?

A peristaltic pump or the nebulizer vacuum draws sample into a nebulizer, where it forms an aerosol that mixes with fuel and oxidant gases in a burner head. Combustion produces a steady cloud of ground-state atoms. A hollow-cathode lamp specific to the element emits sharp resonance lines that pass through the flame to a monochromator and photodetector. Absorbance is proportional to concentration according to the Beer-Lambert law. The flame composition, burner slot geometry and observation height are chosen so that atomization is efficient and chemical interferences are limited. Deuterium or Zeeman background correction removes signals from smoke, droplets and molecular species. Calibration is performed with aqueous standards matched to the sample acid and matrix, and burner rotation or a flow spoiler extends the linear range for concentrated samples.

What are the key features?

  • Small footprint with a short optical bench
  • Single or manually changed lamp position
  • Manual or semi-automatic gas control
  • Fixed spectral bandwidth for simple operation
  • Low gas and power demand for mobile use
  • Quick setup and straightforward maintenance

What are the technical specifications?

A typical compact flame aas for teaching and field laboratories configuration offers wavelength range of 190–800 nm, optical system of compact single-beam, spectral bandwidth of fixed, 0.7 nm typical, lamp positions of 1 or 2, manual change, flame type of air-acetylene and detection limit of 0.005–0.2 mg/L typical. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Compact Flame AAS for Teaching and Field Laboratories is used in university and college teaching laboratories, mobile water and soil testing units, small factory incoming material checks and field screening of beverages and agricultural samples. Across the wider Flame AAS class, laboratories also deploy it for metals in drinking water and wastewater, soil, plant and fertilizer nutrient analysis and food and beverage mineral and toxic metal testing.

Which standards and certifications apply?

Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, ISO 8288 Water quality — Flame atomic absorption determination of metals, US EPA Method 7000B, ASTM D4691 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Flame atomic absorption requires a flame hood, secure gas cylinders, regulators and flashback arrestors, with acetylene kept away from oxidizing materials. Install the instrument on a stable bench away from strong drafts, because airflow disturbs the flame. Daily checks include gas pressure, burner cleanliness and calibration verification. The burner slot and nebulizer need periodic cleaning to remove salt deposits that cause noise and drift. Hollow-cathode lamps have limited life and may need warm-up and alignment. Sample solutions should be filtered and matched to standards in acid content, and method blanks track contamination. Keep service and lamp records for traceability.

How do I select the right Compact Flame AAS for Teaching and Field Laboratories?

Select the compact variant when cost, size and simplicity outweigh automation, for teaching, mobile testing or a small fixed element list. Confirm that the fixed bandwidth and wavelength range cover your elements and that the detection limits meet the method. If sample throughput grows or regulated data handling is needed, a larger automated system is the better long-term investment.

How does it compare with other Flame AAS variants?

Select a flame system by the element list, concentration range and matrix. Single-beam optics suit most routine work at lower cost, while double-beam optics reduce drift from lamp and detector fluctuations for long unattended runs. An autosampler is essential for throughput and reproducibility in quality-control laboratories. If refractory elements such as aluminum, titanium or vanadium are required, choose a system with a nitrous oxide-acetylene burner and appropriate safety provisions. Alkali metals can be measured in flame emission mode, which improves sensitivity and avoids hollow-cathode lamp cost. Confirm burner materials suit your acid and dissolved-solids levels, and check that the gas control and interlocks meet local regulations.

Full specifications

Full specifications
Wavelength range190–800 nm
Optical systemcompact single-beam
Spectral bandwidthfixed, 0.7 nm typical
Lamp positions1 or 2, manual change
Flame typeair-acetylene
Detection limit0.005–0.2 mg/L typical
Background correctionoptional deuterium
Weightapproximately 25 kg
Power supply100–240 V AC, 50/60 Hz
Gas consumptionacetylene 1.5–2.5 L/min

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • University and college teaching laboratories
  • Mobile water and soil testing units
  • Small factory incoming material checks
  • Field screening of beverages and agricultural samples

Key features

  • Small footprint with a short optical bench
  • Single or manually changed lamp position
  • Manual or semi-automatic gas control
  • Fixed spectral bandwidth for simple operation
  • Low gas and power demand for mobile use
  • Quick setup and straightforward maintenance

Frequently asked questions about Compact Flame AAS for Teaching and Field Laboratories

It can produce valid data if the method is validated, calibration and quality-control procedures are followed, and records are complete. However, limited automation, fixed bandwidth and basic background correction may not meet some regulated method requirements. Confirm the specific method and data integrity expectations before relying on a compact instrument.