Automatic Atmospheric Distillation Analyzer with Refrigerated Condenser
带制冷冷凝器的自动常压蒸馏分析仪
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

石油产品手动常压蒸馏装置
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Test method | ASTM D86 manual, ISO 3405, GB/T 6536 |
|---|---|
| Sample volume | 100 mL |
| Temperature range | 0–400 °C |
| Flask volume | 125 mL |
| Receiver | 100 mL graduated cylinder, 1 mL divisions |
| Condenser bath | Ice or refrigerated, 0–60 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D86, ASTM D1160, ASTM D2887
A manual atmospheric distillation apparatus boils a 100 mL petroleum sample in a standard flask while the operator regulates heat and reads the condensate volume and temperature by eye. It suits laboratories running occasional ASTM D86 or ISO 3405 tests on gasoline, kerosene, diesel and naphtha at low capital cost.
A manual atmospheric distillation apparatus boils a 100 mL petroleum sample in a standard flask while the operator regulates heat and reads the condensate volume and temperature by eye. It suits laboratories running occasional ASTM D86 or ISO 3405 tests on gasoline, kerosene, diesel and naphtha at low capital cost.
The manual apparatus consists of a 125 mL distillation flask, a shielded heater with a manually adjusted power control, a condenser tube in a cooling bath, a graduated 100 mL receiving cylinder and a temperature sensor positioned at the flask neck. The operator controls the heat input to meet the initial boiling rate of 5 to 10 minutes from start to first drop and then 4 to 5 mL per minute, reading the temperature when the initial boiling point occurs and at recovery volumes specified in the method. A refrigerated or ice bath cools the condenser for volatile samples. Results depend on operator judgment for volume reading, heating adjustment and timing, so training is important. Barometric pressure is recorded manually and used to correct observed temperatures. The instrument has simple maintenance needs and uses standard replaceable glassware, which suits basic laboratories.
A distillation tester heats a measured sample in a flask so that it boils and the vapor passes through a condenser held at a controlled temperature. The condensate is collected in a graduated receiver, and the vapor temperature is recorded at the initial boiling point and as specific volumes are recovered, such as 5, 10, 50, 90 and 95 percent, up to the final boiling point. The heating rate is adjusted to keep the distillation rate within method limits. Apparatus includes the flask, heater, condenser bath, receiver cylinder and temperature sensor. Automatic models add level-tracking sensors and refrigeration. Vacuum methods reduce pressure so heavy oils distill without thermal cracking, and simulated distillation uses gas chromatography to infer boiling distribution from retention time. Barometric correction is applied to atmospheric results.
A typical manual atmospheric distillation apparatus for petroleum products configuration offers test method of ASTM D86 manual, ISO 3405, GB/T 6536, sample volume of 100 mL, temperature range of 0–400 °C, flask volume of 125 mL, receiver of 100 mL graduated cylinder, 1 mL divisions and condenser bath of Ice or refrigerated, 0–60 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Manual Atmospheric Distillation Apparatus for Petroleum Products is used in kerosene and diesel testing, solvent and naphtha boiling range, teaching laboratories and occasional fuel checks. Across the wider Distillation Testers class, laboratories also deploy it for gasoline and diesel volatility control, jet fuel and kerosene specification testing and naphtha and solvent boiling range.
Relevant standards and methods include ASTM D86, ASTM D1160, ASTM D2887, ASTM D7345, ISO 3405, IP 123, GB/T 6536 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install distillation testers in a ventilated area with stable room temperature, because ambient conditions affect condenser and receiver temperatures. Use properly dimensioned flasks, supports and baffles, since small changes in geometry alter results. Calibrate temperature probes and level sensors against traceable standards, and run check samples such as reference toluene or certified reference fuels at defined intervals. Check refrigerated baths for coolant level and temperature stability. Clean condenser tubes regularly to prevent residue carry-over, and inspect glassware for cracks before heating. Record barometric pressure and apply corrections where the method requires. Dispose of distillation residues as flammable waste. For vacuum systems, verify leak tightness and pressure gauge calibration before each series.
Choose the manual apparatus for occasional testing or training where labor cost is low and a few samples per day are needed. It is less repeatable than automatic units. In an RFQ specify the ASTM D86 sample groups, cooling bath type, thermometer or probe requirements, and whether glassware sets are included.
Begin with the method and product type. ASTM D86 atmospheric distillation covers gasoline, diesel, kerosene and naphtha, while heavy oils that decompose at atmospheric boiling points need vacuum distillation under D1160. Decide between manual and automatic operation: manual apparatus is inexpensive but needs constant attention and is operator-dependent, whereas automatic units control heating profiles, track volume electronically and apply corrections. Small sample volumes or many samples favor micro-distillation, and full boiling distributions from small samples favor simulated distillation by gas chromatography, which needs a different skill set. Check condenser cooling capability, since light gasoline requires near 0 °C baths, and confirm the apparatus supports the sample groups you test. Also compare footprint, fume extraction needs and glassware replacement costs.
| Test method | ASTM D86 manual, ISO 3405, GB/T 6536 |
|---|---|
| Sample volume | 100 mL |
| Temperature range | 0–400 °C |
| Flask volume | 125 mL |
| Receiver | 100 mL graduated cylinder, 1 mL divisions |
| Condenser bath | Ice or refrigerated, 0–60 °C |
| Heater power | 0–1000 W adjustable |
| Temperature resolution | 0.1 °C |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
A single D86 run takes roughly 30 to 45 minutes including setup, distillation and cool-down. One operator can therefore complete about 8 to 10 tests per day on one apparatus. Higher throughput calls for automatic units or several manual stations.
Correct heat adjustment, reading the meniscus and timing the initial boiling point affect repeatability. The method specifies rates the operator must meet. Training with check samples and comparing with reference values helps operators produce consistent results.
Yes, for ASTM D86 the observed temperatures are corrected to 101.3 kPa, because boiling point depends on pressure. Some laboratories use a separate barometer, and the correction can be calculated manually or in a spreadsheet following the method equations.
It measures the boiling range of a petroleum product, recording vapor temperature at the initial boiling point, at fixed recovered volumes such as 10, 50 and 90 percent, and at the final boiling point. These values describe volatility and help predict engine performance and evaporation losses.
ASTM D86 is atmospheric distillation for gasoline, diesel, kerosene and naphtha. D1160 uses reduced pressure to distill heavier oils, up to about 400 °C atmospheric equivalent, that would crack at atmospheric boiling temperature. Product type and boiling range decide which method applies.
Condenser temperature affects how completely vapors liquefy. Too warm a bath loses light ends and lowers recovered volume, while too cold a bath may freeze waxy components. D86 specifies bath temperature by sample group, from 0 to 60 °C, so refrigerated baths are usually required.