Micro-Distillation Analyzer for Fuels
燃料微量蒸馏分析仪
- SKU DTE-0004
- Distillation Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Test method | ASTM D7345, IP 619 |
|---|---|
| Sample volume | 6 mL |
| Temperature range | Ambient to 400 °C |
| Analysis time | 10–15 min |
| Temperature resolution | 0.1 °C |
| Volume resolution | 0.05 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D86, ASTM D1160, ASTM D2887
What is the Micro-Distillation Analyzer for Fuels?
A micro-distillation analyzer performs ASTM D7345 distillation with only 6 mL of sample, using a small flask, controlled heating and a thermal sensor with integrated volume measurement. It is used for rapid boiling range checks on gasoline, diesel and aviation fuel when sample volume and analysis time matter.
What is the Micro-Distillation Analyzer for Fuels?
A micro-distillation analyzer performs ASTM D7345 distillation with only 6 mL of sample, using a small flask, controlled heating and a thermal sensor with integrated volume measurement. It is used for rapid boiling range checks on gasoline, diesel and aviation fuel when sample volume and analysis time matter.
Overview
Micro-distillation compresses the D86 concept into a miniature format. A 6 mL sample is placed in a small flask and heated at a controlled rate while vapor passes through a short condenser, often thermoelectrically cooled. An integrated sensor measures temperature and the volume of condensate directly in a small receiver, so the test completes in about 10 to 15 minutes. The method, ASTM D7345, states correlation to D86 results through a bias equation, and instruments often apply it automatically to report D86-equivalent data. Advantages include low sample consumption, reduced solvent and waste, and shorter cycle times, which suit process laboratories. The small scale makes the instrument more sensitive to sample handling, leakage of light ends and calibration, so careful technique is needed. Some models include autosamplers and sample cooling to reduce evaporative loss.
How does it work?
A distillation tester heats a measured sample in a flask so that it boils and the vapor passes through a condenser held at a controlled temperature. The condensate is collected in a graduated receiver, and the vapor temperature is recorded at the initial boiling point and as specific volumes are recovered, such as 5, 10, 50, 90 and 95 percent, up to the final boiling point. The heating rate is adjusted to keep the distillation rate within method limits. Apparatus includes the flask, heater, condenser bath, receiver cylinder and temperature sensor. Automatic models add level-tracking sensors and refrigeration. Vacuum methods reduce pressure so heavy oils distill without thermal cracking, and simulated distillation uses gas chromatography to infer boiling distribution from retention time. Barometric correction is applied to atmospheric results.
What are the key features?
- Only 6 mL sample per analysis
- Thermoelectric condenser with no external chiller
- Integrated volume and temperature sensing
- Results correlated to D86 through bias equation
- Short cycle time of about 10–15 minutes
- Optional autosampler with sample cooling
What are the technical specifications?
A typical micro-distillation analyzer for fuels configuration offers test method of ASTM D7345, IP 619, sample volume of 6 mL, temperature range of Ambient to 400 °C, analysis time of 10–15 min, temperature resolution of 0.1 °C and volume resolution of 0.05 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Micro-Distillation Analyzer for Fuels is used in process laboratory fuel monitoring, biofuel blend screening, research with limited sample volumes and field and mobile laboratories. Across the wider Distillation Testers class, laboratories also deploy it for gasoline and diesel volatility control, jet fuel and kerosene specification testing and naphtha and solvent boiling range.
Which standards and certifications apply?
Relevant standards and methods include ASTM D86, ASTM D1160, ASTM D2887, ASTM D7345, ISO 3405, IP 123, GB/T 6536 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install distillation testers in a ventilated area with stable room temperature, because ambient conditions affect condenser and receiver temperatures. Use properly dimensioned flasks, supports and baffles, since small changes in geometry alter results. Calibrate temperature probes and level sensors against traceable standards, and run check samples such as reference toluene or certified reference fuels at defined intervals. Check refrigerated baths for coolant level and temperature stability. Clean condenser tubes regularly to prevent residue carry-over, and inspect glassware for cracks before heating. Record barometric pressure and apply corrections where the method requires. Dispose of distillation residues as flammable waste. For vacuum systems, verify leak tightness and pressure gauge calibration before each series.
How do I select the right Micro-Distillation Analyzer for Fuels?
Select micro-distillation for low sample use, short analysis times and lower waste, or for mobile laboratories. Confirm that your specification accepts D7345 results, since some limits are defined only by D86. In an RFQ specify the sample types, autosampler need and whether D86 bias correction reporting is required.
How does it compare with other Distillation Testers variants?
Begin with the method and product type. ASTM D86 atmospheric distillation covers gasoline, diesel, kerosene and naphtha, while heavy oils that decompose at atmospheric boiling points need vacuum distillation under D1160. Decide between manual and automatic operation: manual apparatus is inexpensive but needs constant attention and is operator-dependent, whereas automatic units control heating profiles, track volume electronically and apply corrections. Small sample volumes or many samples favor micro-distillation, and full boiling distributions from small samples favor simulated distillation by gas chromatography, which needs a different skill set. Check condenser cooling capability, since light gasoline requires near 0 °C baths, and confirm the apparatus supports the sample groups you test. Also compare footprint, fume extraction needs and glassware replacement costs.
Full specifications
| Test method | ASTM D7345, IP 619 |
|---|---|
| Sample volume | 6 mL |
| Temperature range | Ambient to 400 °C |
| Analysis time | 10–15 min |
| Temperature resolution | 0.1 °C |
| Volume resolution | 0.05 mL |
| Condenser cooling | Thermoelectric, about 0–5 °C |
| Autosampler capacity | Up to 12 samples (optional) |
| Data output | USB, Ethernet |
| Power supply | 220 V, 50 Hz, 600 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Process laboratory fuel monitoring
- Biofuel blend screening
- Research with limited sample volumes
- Field and mobile laboratories
Key features
- Only 6 mL sample per analysis
- Thermoelectric condenser with no external chiller
- Integrated volume and temperature sensing
- Results correlated to D86 through bias equation
- Short cycle time of about 10–15 minutes
- Optional autosampler with sample cooling
Frequently asked questions about Micro-Distillation Analyzer for Fuels
It correlates with D86 through a bias correction in ASTM D7345, but results are not identical. Some specifications accept D7345, while others require D86 only. Check with your regulator or customer before replacing D86 instruments.
The main advantages are the small 6 mL sample, faster analysis of about 10 to 15 minutes, less waste and lower cooling needs. These benefits suit process laboratories that test many samples and need quick feedback.
It can, because light components may evaporate during sample handling and a small volume amplifies losses. Use chilled, sealed sample containers, inject promptly, and follow the method for sample preparation to keep results representative.
It measures the boiling range of a petroleum product, recording vapor temperature at the initial boiling point, at fixed recovered volumes such as 10, 50 and 90 percent, and at the final boiling point. These values describe volatility and help predict engine performance and evaporation losses.
ASTM D86 is atmospheric distillation for gasoline, diesel, kerosene and naphtha. D1160 uses reduced pressure to distill heavier oils, up to about 400 °C atmospheric equivalent, that would crack at atmospheric boiling temperature. Product type and boiling range decide which method applies.
Condenser temperature affects how completely vapors liquefy. Too warm a bath loses light ends and lowers recovered volume, while too cold a bath may freeze waxy components. D86 specifies bath temperature by sample group, from 0 to 60 °C, so refrigerated baths are usually required.