Large-Volume Viral Nucleic Acid Extraction System

大体积病毒核酸提取系统

  • SKU DRE-0003
  • DNA/RNA Extraction
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • IVDR (EU) 2017/746 (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample volume1-50 mL
Sample capacity4-24 per run
Elution volume30-100 µL
Concentration factor50-500 fold
Run time60-120 min
Lysis temperatureAmbient to 90 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 13485 manufacturing, ISO 15189, CLSI MM13-A

What is the Large-Volume Viral Nucleic Acid Extraction System?

An automated system that processes input volumes from 1 to 50 mL of plasma, serum or swab medium to concentrate low-titre viral nucleic acid. It is used for viral load testing and pathogen surveillance with low-abundance targets.

What is the Large-Volume Viral Nucleic Acid Extraction System?

An automated system that processes input volumes from 1 to 50 mL of plasma, serum or swab medium to concentrate low-titre viral nucleic acid. It is used for viral load testing and pathogen surveillance with low-abundance targets.

Overview

The large-volume system concentrates nucleic acid from liquid samples that contain very few target copies, such as plasma for viral load monitoring, cell-free DNA samples or wastewater surveillance specimens. Lysis is performed in a larger vessel with carrier RNA or a carrier nucleic acid to reduce losses, and binding uses a high bead-to-volume ratio, sometimes with a vacuum or centrifugation concentration step before magnetic capture. Elution volumes stay small, typically 30 to 100 µL, so the target is concentrated by a factor of 50 to 500. Run times are longer than standard bead protocols, usually 60 to 120 minutes, because large volumes must be mixed and washed thoroughly. Some models accept both large and standard tubes so that a single instrument covers several workflows.

How does it work?

Extraction begins with lysis, which uses chaotropic salts, detergents and often proteinase K to break cell membranes and denature nucleases. Nucleic acids then bind to a solid phase, either silica in the presence of high salt or magnetic beads with a silica or carboxyl surface. Washing removes proteins, salts and inhibitors, and elution in a low-salt buffer or nuclease-free water releases purified nucleic acid. Automated instruments move magnetic particles with a magnetic rod, or pipette liquid through a filter plate, following a program that controls lysis time, mixing, bead collection, wash steps and heated elution. Yield and purity are checked by absorbance at 260, 280 and 230 nm or by fluorescent dyes. Carryover between samples and cross-contamination are controlled by tip changes, sealed consumables and controlled airflow.

What are the key features?

  • Input volumes from 1 to 50 mL per sample.
  • Carrier RNA addition to improve recovery at low titre.
  • Concentration factor of 50 to 500 into small elution volume.
  • High bead-to-volume ratio for complete capture.
  • Lower throughput, typically 4 to 24 samples per run.
  • Optional vacuum or centrifugation concentration module.

What are the technical specifications?

A typical large-volume viral nucleic acid extraction system configuration offers sample volume of 1-50 mL, sample capacity of 4-24 per run, elution volume of 30-100 µL, concentration factor of 50-500 fold, run time of 60-120 min and lysis temperature of Ambient to 90 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Large-Volume Viral Nucleic Acid Extraction System is used in viral load monitoring, cell-free DNA extraction from plasma, wastewater and environmental surveillance and low-titre pathogen detection in serum. Across the wider DNA/RNA Extraction class, laboratories also deploy it for clinical pathogen nucleic acid testing, cancer genomics and mutation analysis and next-generation sequencing library preparation.

Which standards and certifications apply?

Relevant standards and methods include ISO 13485 manufacturing, ISO 15189, CLSI MM13-A, IEC 61010-1 and IVDR (EU) 2017/746. Certification candidates for this model are CE, ISO 13485 manufacturing and IVDR (EU) 2017/746; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Keep extraction and amplification areas physically separate, use dedicated pipettes and filter tips, and clean surfaces with fresh hypochlorite or a validated decontaminant. Note that guanidine-based lysis waste must not be mixed with bleach, because toxic gas can form; collect and dispose of it separately under local rules. Wear gloves and change them frequently, since skin and breath carry nucleases and amplification products. Run negative controls in every batch and monitor extraction efficiency with a known standard. Calibrate heating blocks, pipetting accuracy and any magnetic rod height at fixed intervals. Validate each new sample matrix for yield, purity and inhibitor carryover before routine use, and keep lot records of reagents.

How do I select the right Large-Volume Viral Nucleic Acid Extraction System?

Select this variant when the target is present at low concentration and a larger sample input is the only way to reach the assay's detection limit. Confirm the maximum input volume, the concentration factor, the elution volume and whether carrier nucleic acid is compatible with your assay. Verify recovery with spiked samples at the low end of your working range.

How does it compare with other DNA/RNA Extraction variants?

Start with the sample: whole blood, tissue, swabs, plasma, plant material or environmental samples each need a different lysis protocol, and input volume drives consumable and platform choice. Next set throughput, whether a few samples per run or several hundred per day, because this decides between manual manifolds, small benchtop instruments and 96-well platforms. Consider the elution volume and concentration required by the downstream assay, since quantitative PCR and sequencing have different sensitivity to inhibitors and RNA integrity. Check contamination controls such as sealed cartridges, UV decontamination, tip management and negative controls. Confirm that the reagents, plasticware and software are supplied continuously, and ask for validated protocols for each matrix you intend to process.

Full specifications

Full specifications
Sample volume1-50 mL
Sample capacity4-24 per run
Elution volume30-100 µL
Concentration factor50-500 fold
Run time60-120 min
Lysis temperatureAmbient to 90 °C
Carrier additiveCarrier RNA or carrier nucleic acid
Detection sensitivity targetDown to 20-100 copies/mL plasma
Contamination controlSealed single-use vessels, UV option
Power supply220 V, 50 Hz, 300-800 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Viral load monitoring
  • Cell-free DNA extraction from plasma
  • Wastewater and environmental surveillance
  • Low-titre pathogen detection in serum

Key features

  • Input volumes from 1 to 50 mL per sample.
  • Carrier RNA addition to improve recovery at low titre.
  • Concentration factor of 50 to 500 into small elution volume.
  • High bead-to-volume ratio for complete capture.
  • Lower throughput, typically 4 to 24 samples per run.
  • Optional vacuum or centrifugation concentration module.

Frequently asked questions about Large-Volume Viral Nucleic Acid Extraction System

At low target concentrations, nucleic acid adsorbs to tube and bead surfaces and is lost. A carrier such as RNA or glycogen occupies those sites, so recovery of the target becomes more consistent and repeatable.