Skip to main content
Lab Manufacturers China
Magnetic Bead Nucleic Acid Extraction System — product photo

Magnetic Bead Nucleic Acid Extraction System

磁珠法核酸提取系统

  • SKU DRE-0001
  • DNA/RNA Extraction
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • IVDR (EU) 2017/746 (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample capacity16-32 per run
Sample volume20-1,000 µL, up to 10 mL optional
Lysis heating rangeAmbient to 105 °C
Elution volume30-200 µL
Run time20-60 min
Mixing methodOscillation or magnetic stirring
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 13485 manufacturing, ISO 15189, CLSI MM13-A

What is the Magnetic Bead Nucleic Acid Extraction System?

A benchtop automated instrument that mixes samples with magnetic beads and moves them through lysis, wash and elution plates. It processes 16 to 32 samples per run without columns or centrifugation and suits routine molecular laboratories.

What is the Magnetic Bead Nucleic Acid Extraction System?

A benchtop automated instrument that mixes samples with magnetic beads and moves them through lysis, wash and elution plates. It processes 16 to 32 samples per run without columns or centrifugation and suits routine molecular laboratories.

Overview

The magnetic bead extraction system holds samples in a deep-well plate or strip and uses a magnetic rod or a pipetting head to collect and release the beads. Lysis buffer and proteinase K are added by the instrument, binding occurs with mixing or heating, and beads are then washed two or three times before elution into a small volume. A heated block assists lysis and elution, and mixing can be achieved by oscillation, rotation or magnetic stirring. The magnetic bead method is fast, uses no vacuum or centrifugation and transfers well to automation, with typical run times of 20 to 60 minutes for 16 to 32 samples. Yield depends on bead binding capacity and the lysis efficiency for the matrix. The instrument needs only a small bench footprint and a standard mains supply.

How does it work?

Extraction begins with lysis, which uses chaotropic salts, detergents and often proteinase K to break cell membranes and denature nucleases. Nucleic acids then bind to a solid phase, either silica in the presence of high salt or magnetic beads with a silica or carboxyl surface. Washing removes proteins, salts and inhibitors, and elution in a low-salt buffer or nuclease-free water releases purified nucleic acid. Automated instruments move magnetic particles with a magnetic rod, or pipette liquid through a filter plate, following a program that controls lysis time, mixing, bead collection, wash steps and heated elution. Yield and purity are checked by absorbance at 260, 280 and 230 nm or by fluorescent dyes. Carryover between samples and cross-contamination are controlled by tip changes, sealed consumables and controlled airflow.

What are the key features?

  • Magnetic rod or pipetting head for bead transfer.
  • Heated block for lysis and elution steps.
  • 16 to 32 sample capacity per run in deep-well plates.
  • No vacuum or centrifugation required.
  • Programmable protocols stored on a touch screen.
  • Run time of 20 to 60 minutes depending on protocol.

What are the technical specifications?

A typical magnetic bead nucleic acid extraction system configuration offers sample capacity of 16-32 per run, sample volume of 20-1,000 µL, up to 10 mL optional, lysis heating range of Ambient to 105 °C, elution volume of 30-200 µL, run time of 20-60 min and mixing method of Oscillation or magnetic stirring. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Magnetic Bead Nucleic Acid Extraction System is used in clinical sample nucleic acid preparation, animal and plant tissue DNA extraction, viral RNA extraction from swabs and bacterial culture DNA isolation. Across the wider DNA/RNA Extraction class, laboratories also deploy it for clinical pathogen nucleic acid testing, cancer genomics and mutation analysis and next-generation sequencing library preparation.

Which standards and certifications apply?

Relevant standards and methods include ISO 13485 manufacturing, ISO 15189, CLSI MM13-A, IEC 61010-1 and IVDR (EU) 2017/746. Certification candidates for this model are CE, ISO 13485 manufacturing and IVDR (EU) 2017/746; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Keep extraction and amplification areas physically separate, use dedicated pipettes and filter tips, and clean surfaces with fresh hypochlorite or a validated decontaminant. Note that guanidine-based lysis waste must not be mixed with bleach, because toxic gas can form; collect and dispose of it separately under local rules. Wear gloves and change them frequently, since skin and breath carry nucleases and amplification products. Run negative controls in every batch and monitor extraction efficiency with a known standard. Calibrate heating blocks, pipetting accuracy and any magnetic rod height at fixed intervals. Validate each new sample matrix for yield, purity and inhibitor carryover before routine use, and keep lot records of reagents.

How do I select the right Magnetic Bead Nucleic Acid Extraction System?

Select this variant for routine extraction where 16 to 32 samples per run match daily demand and the bead protocol has been validated for your matrices. Check the supported plate or strip format, lysis temperature range, elution volume options and whether a UV lamp is fitted. Specify the sample types you process, since bead chemistry and lysis conditions change with matrix.

How does it compare with other DNA/RNA Extraction variants?

Start with the sample: whole blood, tissue, swabs, plasma, plant material or environmental samples each need a different lysis protocol, and input volume drives consumable and platform choice. Next set throughput, whether a few samples per run or several hundred per day, because this decides between manual manifolds, small benchtop instruments and 96-well platforms. Consider the elution volume and concentration required by the downstream assay, since quantitative PCR and sequencing have different sensitivity to inhibitors and RNA integrity. Check contamination controls such as sealed cartridges, UV decontamination, tip management and negative controls. Confirm that the reagents, plasticware and software are supplied continuously, and ask for validated protocols for each matrix you intend to process.

Full specifications

Full specifications
Sample capacity16-32 per run
Sample volume20-1,000 µL, up to 10 mL optional
Lysis heating rangeAmbient to 105 °C
Elution volume30-200 µL
Run time20-60 min
Mixing methodOscillation or magnetic stirring
Typical yield1-10 µg DNA from 200 µL blood
PurityA260/280 1.7-1.9 for DNA
Contamination controlUV lamp option, filter tips, sealed plates
Power supply220 V, 50 Hz, 200-500 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Clinical sample nucleic acid preparation
  • Animal and plant tissue DNA extraction
  • Viral RNA extraction from swabs
  • Bacterial culture DNA isolation

Key features

  • Magnetic rod or pipetting head for bead transfer.
  • Heated block for lysis and elution steps.
  • 16 to 32 sample capacity per run in deep-well plates.
  • No vacuum or centrifugation required.
  • Programmable protocols stored on a touch screen.
  • Run time of 20 to 60 minutes depending on protocol.

Frequently asked questions about Magnetic Bead Nucleic Acid Extraction System

Typically 20 to 60 minutes including lysis, binding, two or three washes and elution, depending on whether lysis is heated and how many samples are processed. Rapid protocols skip drying steps but may reduce yield for some matrices.

Request a quotation for the Magnetic Bead Nucleic Acid Extraction System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote