Portable Dissolved Oxygen Meter
便携式溶解氧测定仪
- SKU DOM-0002
- Dissolved Oxygen Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1–0.5 mg/L |
| Resolution | 0.01 mg/L |
| Response time | 30–60 s to 90% |
| Temperature range | −5–50 °C |
| Compensation | Automatic temperature, manual salinity and pressure |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 5814, ASTM D888, APHA 4500-O Standard Methods
What is the Portable Dissolved Oxygen Meter?
A portable dissolved oxygen meter is a battery-powered handheld instrument with an IP-rated housing and a cable-mounted probe for field measurement in rivers, lakes, tanks and treatment works. It logs readings with time stamps and is used for surveys, plant rounds and compliance sampling.
What is the Portable Dissolved Oxygen Meter?
A portable dissolved oxygen meter is a battery-powered handheld instrument with an IP-rated housing and a cable-mounted probe for field measurement in rivers, lakes, tanks and treatment works. It logs readings with time stamps and is used for surveys, plant rounds and compliance sampling.
Overview
Portable meters use an IP65 to IP67 housing and batteries lasting 100 to 500 hours, with cables from 1 m to 100 m for boreholes and deep tanks. Both galvanic or polarographic and optical probes are available; optical versions need no flow, tolerate fouling better and keep calibration for months, which suits extended field campaigns. Ranges cover 0 to 20 mg/L or 0 to 50 mg/L with accuracy of plus or minus 0.1 to 0.5 mg/L, and percent saturation, temperature and sometimes salinity are displayed. On-board logging of hundreds to several thousand points with time stamps, and Bluetooth or USB transfer, simplifies reporting and mapping. Some models combine dissolved oxygen with pH, conductivity, turbidity or ORP in one multiparameter instrument. Rugged cases hold calibration cups, spare membranes, electrolyte and a field record book.
How does it work?
Electrochemical sensors are either galvanic or polarographic. Oxygen diffuses through a gas-permeable membrane into an electrolyte, where it is reduced at a cathode; the resulting current is proportional to the oxygen partial pressure. Polarographic cells need an applied voltage of about 0.7 V and a warm-up period, while galvanic cells generate their own current. Optical sensors use a luminescent dye immobilized in a film: blue light excites the dye, the emitted red light is quenched by oxygen, and the phase shift of the signal gives the oxygen concentration. Optical sensors need no electrolyte, flow, or polishing and hold calibration for months. Both types measure partial pressure, so salinity and barometric pressure corrections are applied to report concentration in mg/L, and a temperature sensor compensates the membrane permeability or dye response. Stirring or flow across the membrane is required for electrochemical sensors to avoid oxygen depletion at the surface.
What are the key features?
- IP67 sealed housing with backlit display for field use
- Battery operation for 100 to 500 hours on alkaline cells
- Cables from 1 m to 100 m for boreholes, lakes and tanks
- Optical or electrochemical probe options with quick connectors
- Data logging of 500 to 5000 records with GPS-ready time stamps
- Bluetooth or USB transfer to phones, tablets and computers
What are the technical specifications?
A typical portable dissolved oxygen meter configuration offers measuring range of 0–20 mg/L (0–200% saturation), accuracy of ±0.1–0.5 mg/L, resolution of 0.01 mg/L, response time of 30–60 s to 90%, temperature range of −5–50 °C and compensation of Automatic temperature, manual salinity and pressure. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Portable Dissolved Oxygen Meter is used in river, lake and reservoir surveys, wastewater treatment plant rounds, aquaculture pond monitoring, groundwater sampling and environmental compliance campaigns. Across the wider Dissolved Oxygen Meters class, laboratories also deploy it for municipal wastewater aeration control, fermentation and bioprocess monitoring and aquaculture pond and tank control.
Which standards and certifications apply?
Relevant standards and methods include ISO 5814, ASTM D888, APHA 4500-O Standard Methods, EN 25814, GB/T 11913 and USP <1231>. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate electrochemical sensors in water-saturated air or against a reference method such as Winkler titration, and replace the membrane, electrolyte and O-ring at the interval the manufacturer specifies, commonly every one to three months. Keep the membrane free of deposits: biological growth in wastewater reduces response and must be cleaned without scratching the surface. Optical sensors need only periodic recalibration, but the sensing cap has a finite life of roughly one to two years and must be replaced. Zero-point checks with sodium sulfite solution confirm that the instrument reads low oxygen correctly. Record temperature, salinity and barometric pressure corrections with the data, and verify performance with a check standard or comparison measurement. For compliance work, follow the method required by the permit or pharmacopoeia and retain calibration and maintenance records.
How do I select the right Portable Dissolved Oxygen Meter?
Choose a portable meter for measurements at the sampling point, especially in long cables and deep water. For continuous aeration control use an online analyzer. In an RFQ, state probe type, cable length, required accuracy, correction features, logging capacity, wireless options and whether other water quality parameters are needed.
How does it compare with other Dissolved Oxygen Meters variants?
Choose between electrochemical and optical sensing first. Optical sensors suit long-term unattended monitoring and low-maintenance field work, while electrochemical sensors have lower initial cost and are well established in wastewater aeration control. Then match the format: benchtop meters for laboratory BOD, fermentation and validation work, portable meters with long cables for rivers, lakes and tanks, online analyzers with 4-20 mA outputs for aeration control, and BOD systems that measure depletion over five days. Check the measuring range, accuracy, temperature and salinity compensation, response time, minimum flow or stirring requirement, calibration method and logging capacity. Specify whether readings must be in mg/L, percent saturation or both, and which standards the laboratory follows.
Full specifications
| Measuring range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1–0.5 mg/L |
| Resolution | 0.01 mg/L |
| Response time | 30–60 s to 90% |
| Temperature range | −5–50 °C |
| Compensation | Automatic temperature, manual salinity and pressure |
| Ingress protection | IP67 (meter), IP68 (probe) |
| Battery life | 100–500 h |
| Cable length | 1–100 m |
| Data memory | 500–5000 records |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- River, lake and reservoir surveys
- Wastewater treatment plant rounds
- Aquaculture pond monitoring
- Groundwater sampling
- Environmental compliance campaigns
Key features
- IP67 sealed housing with backlit display for field use
- Battery operation for 100 to 500 hours on alkaline cells
- Cables from 1 m to 100 m for boreholes, lakes and tanks
- Optical or electrochemical probe options with quick connectors
- Data logging of 500 to 5000 records with GPS-ready time stamps
- Bluetooth or USB transfer to phones, tablets and computers
Frequently asked questions about Portable Dissolved Oxygen Meter
Depth is limited by the cable and probe seals rather than the electronics. Probes are typically rated for 30 to 100 m of water and cables are ordered to match, so specify the maximum sampling depth and confirm the pressure rating before use.
Electrochemical probes need water moving past the membrane, which flowing rivers normally provide. In still water, lower the probe and move it gently, or pump water across the membrane, to avoid a low reading caused by oxygen depletion at the surface.
Enter the measured salinity or conductivity to correct the reading, because salt reduces oxygen solubility at a given partial pressure. If the instrument does not correct automatically, record salinity with each reading and apply the correction in the report.
It measures the oxygen dissolved in water, reported in mg/L, ppm or percent of saturation. Temperature, salinity and barometric pressure affect the result, so meters apply corrections to give the concentration an operator or process controller actually needs.
Optical sensors need no electrolyte or flow, drift less and hold calibration for months, which suits unattended monitoring. Electrochemical sensors cost less, respond quickly and are widely used in aeration control, but need membrane and electrolyte service every one to three months.
Electrochemical sensors consume oxygen at the cathode, so a stagnant film of water next to the membrane becomes depleted and the reading falls. A flow of at least 0.3 m per second across the membrane, or gentle stirring in a beaker, keeps the measurement representative.
Related models