Online Dissolved Oxygen Analyzer
在线溶解氧分析仪
- SKU DOM-0004
- Dissolved Oxygen Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1 mg/L |
| Response time | ≤60 s to 90% |
| Operating temperature | 0–50 °C (sample) |
| Pressure rating | up to 1 MPa for submersible versions |
| Analog output | 4-20 mA, isolated |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 5814, ASTM D888, APHA 4500-O Standard Methods
What is the Online Dissolved Oxygen Analyzer?
An online dissolved oxygen analyzer continuously measures oxygen in a process stream or tank and outputs 4-20 mA and alarm signals for aeration blower or valve control. It is used in municipal and industrial wastewater treatment, fish farming and bioprocess applications.
What is the Online Dissolved Oxygen Analyzer?
An online dissolved oxygen analyzer continuously measures oxygen in a process stream or tank and outputs 4-20 mA and alarm signals for aeration blower or valve control. It is used in municipal and industrial wastewater treatment, fish farming and bioprocess applications.
Overview
The analyzer uses an optical or electrochemical probe mounted on a submerged arm, in a flow-through cell or on a floating assembly. Optical probes are common because they need no electrolyte and tolerate long service intervals in activated sludge. The transmitter provides two-wire 4-20 mA or digital Modbus output, alarm relays for high and low oxygen, and often PID control of blowers, valves or variable-frequency drives. Measuring range is typically 0 to 20 mg/L with accuracy of plus or minus 0.1 mg/L, and readings are auto-compensated for temperature, salinity and pressure. Automatic cleaning by compressed air or a mechanical wiper keeps the sensor surface clear in fouling environments. Datalogging and trend displays show oxygen profiles, and calibration can be performed in air or against a reference measurement. Installation must consider mixing, probe depth and cable routing to avoid damage and signal noise.
How does it work?
Electrochemical sensors are either galvanic or polarographic. Oxygen diffuses through a gas-permeable membrane into an electrolyte, where it is reduced at a cathode; the resulting current is proportional to the oxygen partial pressure. Polarographic cells need an applied voltage of about 0.7 V and a warm-up period, while galvanic cells generate their own current. Optical sensors use a luminescent dye immobilized in a film: blue light excites the dye, the emitted red light is quenched by oxygen, and the phase shift of the signal gives the oxygen concentration. Optical sensors need no electrolyte, flow, or polishing and hold calibration for months. Both types measure partial pressure, so salinity and barometric pressure corrections are applied to report concentration in mg/L, and a temperature sensor compensates the membrane permeability or dye response. Stirring or flow across the membrane is required for electrochemical sensors to avoid oxygen depletion at the surface.
What are the key features?
- Continuous in-situ measurement with 4-20 mA or Modbus output
- PID control function for blowers, valves and variable-frequency drives
- Automatic compressed-air or wiper cleaning for fouling environments
- High and low oxygen alarm relays with transmitter status diagnostics
- Optical or electrochemical probe options with long service intervals
- Data logging with trend display for profiling and reporting
What are the technical specifications?
A typical online dissolved oxygen analyzer configuration offers measuring range of 0–20 mg/L (0–200% saturation), accuracy of ±0.1 mg/L, response time of ≤60 s to 90%, operating temperature of 0–50 °C (sample), pressure rating of up to 1 MPa for submersible versions and analog output of 4-20 mA, isolated. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online Dissolved Oxygen Analyzer is used in municipal wastewater aeration control, industrial effluent treatment, recirculating aquaculture systems, bioreactor and fermentation monitoring and lake and reservoir oxygen profiling. Across the wider Dissolved Oxygen Meters class, laboratories also deploy it for municipal wastewater aeration control, fermentation and bioprocess monitoring and aquaculture pond and tank control.
Which standards and certifications apply?
Relevant standards and methods include ISO 5814, ASTM D888, APHA 4500-O Standard Methods, EN 25814, GB/T 11913 and USP <1231>. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate electrochemical sensors in water-saturated air or against a reference method such as Winkler titration, and replace the membrane, electrolyte and O-ring at the interval the manufacturer specifies, commonly every one to three months. Keep the membrane free of deposits: biological growth in wastewater reduces response and must be cleaned without scratching the surface. Optical sensors need only periodic recalibration, but the sensing cap has a finite life of roughly one to two years and must be replaced. Zero-point checks with sodium sulfite solution confirm that the instrument reads low oxygen correctly. Record temperature, salinity and barometric pressure corrections with the data, and verify performance with a check standard or comparison measurement. For compliance work, follow the method required by the permit or pharmacopoeia and retain calibration and maintenance records.
How do I select the right Online Dissolved Oxygen Analyzer?
Select an online analyzer when dissolved oxygen drives a control action or must be monitored continuously without staff present. For occasional grab samples, a portable meter is sufficient. In an RFQ, specify range, probe type, cleaning method, output and control functions, mounting arrangement, immersion depth and calibration procedure.
How does it compare with other Dissolved Oxygen Meters variants?
Choose between electrochemical and optical sensing first. Optical sensors suit long-term unattended monitoring and low-maintenance field work, while electrochemical sensors have lower initial cost and are well established in wastewater aeration control. Then match the format: benchtop meters for laboratory BOD, fermentation and validation work, portable meters with long cables for rivers, lakes and tanks, online analyzers with 4-20 mA outputs for aeration control, and BOD systems that measure depletion over five days. Check the measuring range, accuracy, temperature and salinity compensation, response time, minimum flow or stirring requirement, calibration method and logging capacity. Specify whether readings must be in mg/L, percent saturation or both, and which standards the laboratory follows.
Full specifications
| Measuring range | 0–20 mg/L (0–200% saturation) |
|---|---|
| Accuracy | ±0.1 mg/L |
| Response time | ≤60 s to 90% |
| Operating temperature | 0–50 °C (sample) |
| Pressure rating | up to 1 MPa for submersible versions |
| Analog output | 4-20 mA, isolated |
| Digital interface | Modbus RTU/RS-485 |
| Alarm relays | 2–4 programmable |
| Cleaning | Automatic air blast or wiper |
| Enclosure rating | IP65 or IP68 (probe) |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Municipal wastewater aeration control
- Industrial effluent treatment
- Recirculating aquaculture systems
- Bioreactor and fermentation monitoring
- Lake and reservoir oxygen profiling
Key features
- Continuous in-situ measurement with 4-20 mA or Modbus output
- PID control function for blowers, valves and variable-frequency drives
- Automatic compressed-air or wiper cleaning for fouling environments
- High and low oxygen alarm relays with transmitter status diagnostics
- Optical or electrochemical probe options with long service intervals
- Data logging with trend display for profiling and reporting
Frequently asked questions about Online Dissolved Oxygen Analyzer
Mount where flow is representative, usually in an aerated zone or outlet channel, at least 200 mm below the surface and clear of sludge blankets. Avoid dead zones and direct air sparging, and route cables away from motors and variable-frequency drives to reduce noise.
Optical probes usually hold calibration for six to twelve months and are verified monthly or quarterly against a portable meter. Electrochemical probes need membrane and electrolyte service every one to three months. Always record the verification result with the process data.
Small differences are normal and reflect mixing patterns, probe depth and fouling rather than instrument error. Compare after cleaning and calibration; if two probes in the same well differ by more than 0.3 mg/L, check the cleaning system and the reference measurement.
It measures the oxygen dissolved in water, reported in mg/L, ppm or percent of saturation. Temperature, salinity and barometric pressure affect the result, so meters apply corrections to give the concentration an operator or process controller actually needs.
Optical sensors need no electrolyte or flow, drift less and hold calibration for months, which suits unattended monitoring. Electrochemical sensors cost less, respond quickly and are widely used in aeration control, but need membrane and electrolyte service every one to three months.
Electrochemical sensors consume oxygen at the cathode, so a stagnant film of water next to the membrane becomes depleted and the reading falls. A flow of at least 0.3 m per second across the membrane, or gentle stirring in a beaker, keeps the measurement representative.