Benchtop Short-Read Sequencer — product photo

Benchtop Short-Read Sequencer

台式短读长测序仪

  • SKU DNS-0001
  • DNA Sequencers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Read length75–300 bp (mode dependent)
Output per run15–150 Gb
Run timeapprox. 12–30 h
Raw accuracyover 99% (typical)
Flow cell formatPatterned flow cell, single use
Samples per run24–384 with dual indexing
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 22174, ISO 15189

What is the Benchtop Short-Read Sequencer?

A benchtop short-read sequencer reads 75–300 base fragments with very high accuracy and 15–150 Gb of output per run, covering exomes, RNA sequencing and large panels in a single day. It is the default choice for research and clinical genomics laboratories with moderate throughput.

What is the Benchtop Short-Read Sequencer?

A benchtop short-read sequencer reads 75–300 base fragments with very high accuracy and 15–150 Gb of output per run, covering exomes, RNA sequencing and large panels in a single day. It is the default choice for research and clinical genomics laboratories with moderate throughput.

Overview

The benchtop short-read sequencer packages the chemistry and optics of a production platform into a footprint of roughly half a square metre. Libraries are loaded onto a patterned flow cell, clusters are formed, and sequencing by synthesis proceeds cycle by cycle with four-colour or two-colour imaging. Typical output is 15–150 Gb per run, with read lengths of 75–300 bases and raw error rates below 1%. Run time ranges from about 12 to 30 hours depending on read length. On-board or connected software performs base calling, demultiplexing, alignment and variant calling, and can push results to a laboratory information system. Most models accept a range of library kits, including whole-genome, exome, RNA and amplicon chemistries, and support dual indexing for multiplexing 24–384 samples per run. Turnaround is usually one working day, which suits clinical and core facility workflows.

How does it work?

Most high-throughput sequencers use sequencing by synthesis. A library of adapter-tagged fragments is loaded onto a flow cell or bead surface, where clonal clusters are formed so that each local signal comes from many identical copies. Fluorescently labelled nucleotides with reversible terminators are incorporated one base at a time by a polymerase; after each cycle the instrument images the surface, records the base colour for every cluster, and cleaves the terminator so the next base can be added. Base calls are assembled into reads and aligned to a reference. Nanopore instruments instead pull a single strand through a protein pore and read characteristic current changes for each base. Sanger instruments label fragments with chain-terminating dideoxy nucleotides and separate them by capillary electrophoresis with laser-induced fluorescence detection.

What are the key features?

  • Read lengths from 75 to 300 bases with configurable run modes
  • Output of 15–150 Gb per run for exomes, RNA and large panels
  • On-board base calling, alignment and variant calling software
  • Dual indexing supports 24–384 multiplexed samples per run
  • Load-and-go cartridge reagents reduce hands-on time to minutes
  • Audit trail and laboratory information system connectivity

What are the technical specifications?

A typical benchtop short-read sequencer configuration offers read length of 75–300 bp (mode dependent), output per run of 15–150 Gb, run time of approx. 12–30 h, raw accuracy of over 99% (typical), flow cell format of Patterned flow cell, single use and samples per run of 24–384 with dual indexing. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Benchtop Short-Read Sequencer is used in exome and targeted panel sequencing, RNA sequencing and expression analysis, microbial whole-genome sequencing and clinical variant detection. Across the wider DNA Sequencers class, laboratories also deploy it for whole-genome and exome resequencing, RNA sequencing and gene expression profiling and pathogen whole-genome surveillance.

Which standards and certifications apply?

Relevant standards and methods include ISO 20395, ISO 22174, ISO 15189, CLSI MM09, IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Sequencing instruments need a stable bench, clean power and a room with controlled temperature and low dust, because optics and flow-cell surfaces are sensitive. Illumina-style platforms are typically installed with their own compute server and require a defined data path, backup policy and firewall rules. Budget for consumables per run, flow-cell shelf life and the storage of large sequence files, which often exceeds instrument cost within a few years. Decontaminate the instrument area and use separate pre-PCR and post-PCR rooms to avoid amplicon carry-over. Validate accuracy and reproducibility with a reference genome or control library at installation and after major service. Sequence data from human samples must be handled under local privacy rules and, in clinical use, under ISO 15189 accreditation.

How do I select the right Benchtop Short-Read Sequencer?

Select a benchtop short-read sequencer when exomes, RNA libraries or panels of hundreds of targets make up most of the workload and one-day turnaround is enough. Specify read length, output per run, flow cell options, supported library kits, on-board analysis and whether indexes are open, plus data storage and service response terms.

How does it compare with other DNA Sequencers variants?

Choose a sequencer by read length, output and accuracy rather than by headline specifications. For whole-genome resequencing, exomes, RNA sequencing and large amplicon panels, a benchtop short-read instrument with 15–150 Gb of output per run usually gives the lowest cost per sample and the simplest workflow. Production laboratories with many samples per week should compare cost per gigabase, run time and automated loading, and confirm whether indexes and flow cells are open or proprietary. Long-read platforms are decisive when repeats, structural variants, full-length transcripts or native DNA modifications matter. Keep a capillary sequencer for single-target confirmation, plasmid and amplicon checks where turnaround time dominates. Confirm the supported library kits, on-board or server analysis software, data storage and bioinformatics support before ordering.

Full specifications

Full specifications
Read length75–300 bp (mode dependent)
Output per run15–150 Gb
Run timeapprox. 12–30 h
Raw accuracyover 99% (typical)
Flow cell formatPatterned flow cell, single use
Samples per run24–384 with dual indexing
Input DNA1 ng–1 µg (method dependent)
DetectionFour-colour or two-colour fluorescence imaging
Data outputEthernet, local or network storage
Dimensions (W x D x H)approx. 600 x 550 x 600 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Exome and targeted panel sequencing
  • RNA sequencing and expression analysis
  • Microbial whole-genome sequencing
  • Clinical variant detection

Key features

  • Read lengths from 75 to 300 bases with configurable run modes
  • Output of 15–150 Gb per run for exomes, RNA and large panels
  • On-board base calling, alignment and variant calling software
  • Dual indexing supports 24–384 multiplexed samples per run
  • Load-and-go cartridge reagents reduce hands-on time to minutes
  • Audit trail and laboratory information system connectivity

Frequently asked questions about Benchtop Short-Read Sequencer

Typical output is 15–150 Gb per run depending on the flow cell and read length. That is enough for several exomes, dozens of RNA samples or hundreds of amplicon libraries in one run, and is usually more than a research laboratory consumes weekly.

Related models

All DNA Sequencers
Long-Read Nanopore Sequencer — product photo

Long-Read Nanopore Sequencer

长读长纳米孔测序仪

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Benchtop Short-Read Sequencer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote