Microwave Digestion System

微波消解系统

  • SKU DIG-0002
  • Digesters
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Max temperatureUp to 260 °C
Max pressureUp to 100 bar
Vessel volume50–100 mL
Vessel positions6–40
Microwave power1,000–1,600 W
Vessel materialPTFE-TFM
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA 3051A, EPA 3050B, EPA 200.2

What is the Microwave Digestion System?

A microwave digestion system heats sealed vessels with microwave energy to dissolve difficult samples rapidly. It reaches high temperatures and pressures, retains volatiles and is used for trace elemental analysis in the laboratory.

What is the Microwave Digestion System?

A microwave digestion system heats sealed vessels with microwave energy to dissolve difficult samples rapidly. It reaches high temperatures and pressures, retains volatiles and is used for trace elemental analysis in the laboratory.

Overview

A microwave digestion system places sample and acid in sealed, pressure-rated vessels and heats them with microwave energy, which couples directly with the acid solution and raises temperature rapidly. Because the vessels are closed, temperatures well above the atmospheric boiling point are reached and volatile elements are retained, so difficult matrices dissolve completely with less acid and time than open digestion. A rotating turntable, pressure and temperature sensors and programmable power control the process, and vessels are cooled before opening. The technique is standard for environmental, food, geological and biological samples before ICP and atomic absorption analysis, and reaction control is essential to safety.

How does it work?

Digestion breaks down a sample matrix so that the analytes of interest enter solution in a measurable form. In block digestion, tubes or vessels are heated on a temperature-controlled aluminium block and acid is added, often with reflux. In Kjeldahl digestion, the sample is heated with sulfuric acid and a catalyst to convert nitrogen compounds to ammonium sulfate. In closed-vessel and microwave digestion, acid and sample are sealed in a pressure-rated vessel and heated rapidly, so higher temperatures are reached, volatiles are retained and less acid and time are needed. Reagent choice, temperature, pressure and time determine completeness, and the resulting digest is diluted and filtered before measurement.

What are the key features?

  • Sealed pressure-rated vessels with microwave heating
  • Rapid heating to high temperature
  • Retention of volatile elements
  • Programmable pressure and temperature control
  • Rotating turntable for uniform heating

What are the technical specifications?

A typical microwave digestion system configuration offers max temperature of Up to 260 °C, max pressure of Up to 100 bar, vessel volume of 50–100 mL, vessel positions of 6–40, microwave power of 1,000–1,600 W and vessel material of PTFE-TFM. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Microwave Digestion System is used in trace element analysis in environmental samples, food and feed heavy metal testing, geological and metallurgical sample digestion and pharmaceutical and biological trace analysis. Across the wider Digesters class, laboratories also deploy it for environmental soil, sediment and sludge analysis, food and feed elemental analysis and metals and alloy trace analysis.

Which standards and certifications apply?

Relevant standards and methods include EPA 3051A, EPA 3050B, EPA 200.2, ISO 11466 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Add acids in a fume hood and use the protective equipment specified for the reagent, including face and eye protection, gloves and an acid-resistant apron. Do not exceed the rated temperature or pressure of the vessels, and allow closed vessels to cool before opening to avoid acid spray. Digest a reagent blank and, where required, a certified reference material to verify recovery and completeness. Check vessels for scratches and damage, and replace them on schedule, since worn vessels may fail. Follow the applicable method, such as EPA 3051A, EPA 3050B, ISO 11466 or the Kjeldahl procedure, and record all temperatures, times and reagent volumes.

How do I select the right Microwave Digestion System?

Choose a microwave digestion system for difficult matrices, volatile elements or low detection limits. Confirm the temperature and pressure ratings meet the method, the vessel material suits the acids, and the number of positions matches the workload. Verify that temperature and pressure are monitored in every vessel or in a representative one, and that cooling is adequate.

How does it compare with other Digesters variants?

Choose a digester according to the sample matrix, the analytes and the required detection limits. Block digestion suits routine, high-throughput work with simple matrices and volatile analytes that are retained, such as nitrogen and some metals. Kjeldahl systems are specific to nitrogen and protein determination. Closed-vessel and microwave digestion suit difficult matrices, volatile elements and low detection limits, because they reach higher temperatures and retain volatiles. Automated systems add reagent dosing, heating programmes and cooling for reproducibility. Confirm the vessel material and pressure rating suit the acids used, the temperature reaches the method requirement, and the throughput matches the workload.

Full specifications

Full specifications
Max temperatureUp to 260 °C
Max pressureUp to 100 bar
Vessel volume50–100 mL
Vessel positions6–40
Microwave power1,000–1,600 W
Vessel materialPTFE-TFM
Temperature sensorIn-vessel, fiber optic
Pressure controlAutomatic venting
CoolingForced air or water
Power supply220–240 V AC

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Trace element analysis in environmental samples
  • Food and feed heavy metal testing
  • Geological and metallurgical sample digestion
  • Pharmaceutical and biological trace analysis

Key features

  • Sealed pressure-rated vessels with microwave heating
  • Rapid heating to high temperature
  • Retention of volatile elements
  • Programmable pressure and temperature control
  • Rotating turntable for uniform heating

Frequently asked questions about Microwave Digestion System

Sealing allows the acid to be heated above its atmospheric boiling point, which greatly speeds decomposition, and prevents volatile elements such as mercury and arsenic from escaping. The sealed vessel also reduces acid consumption and cross-contamination from the laboratory environment.