Microwave Digestion System
微波消解系统
- SKU DIG-0002
- Digesters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Max temperature | Up to 260 °C |
|---|---|
| Max pressure | Up to 100 bar |
| Vessel volume | 50–100 mL |
| Vessel positions | 6–40 |
| Microwave power | 1,000–1,600 W |
| Vessel material | PTFE-TFM |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA 3051A, EPA 3050B, EPA 200.2
What is the Microwave Digestion System?
A microwave digestion system heats sealed vessels with microwave energy to dissolve difficult samples rapidly. It reaches high temperatures and pressures, retains volatiles and is used for trace elemental analysis in the laboratory.
What is the Microwave Digestion System?
A microwave digestion system heats sealed vessels with microwave energy to dissolve difficult samples rapidly. It reaches high temperatures and pressures, retains volatiles and is used for trace elemental analysis in the laboratory.
Overview
A microwave digestion system places sample and acid in sealed, pressure-rated vessels and heats them with microwave energy, which couples directly with the acid solution and raises temperature rapidly. Because the vessels are closed, temperatures well above the atmospheric boiling point are reached and volatile elements are retained, so difficult matrices dissolve completely with less acid and time than open digestion. A rotating turntable, pressure and temperature sensors and programmable power control the process, and vessels are cooled before opening. The technique is standard for environmental, food, geological and biological samples before ICP and atomic absorption analysis, and reaction control is essential to safety.
How does it work?
Digestion breaks down a sample matrix so that the analytes of interest enter solution in a measurable form. In block digestion, tubes or vessels are heated on a temperature-controlled aluminium block and acid is added, often with reflux. In Kjeldahl digestion, the sample is heated with sulfuric acid and a catalyst to convert nitrogen compounds to ammonium sulfate. In closed-vessel and microwave digestion, acid and sample are sealed in a pressure-rated vessel and heated rapidly, so higher temperatures are reached, volatiles are retained and less acid and time are needed. Reagent choice, temperature, pressure and time determine completeness, and the resulting digest is diluted and filtered before measurement.
What are the key features?
- Sealed pressure-rated vessels with microwave heating
- Rapid heating to high temperature
- Retention of volatile elements
- Programmable pressure and temperature control
- Rotating turntable for uniform heating
What are the technical specifications?
A typical microwave digestion system configuration offers max temperature of Up to 260 °C, max pressure of Up to 100 bar, vessel volume of 50–100 mL, vessel positions of 6–40, microwave power of 1,000–1,600 W and vessel material of PTFE-TFM. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Microwave Digestion System is used in trace element analysis in environmental samples, food and feed heavy metal testing, geological and metallurgical sample digestion and pharmaceutical and biological trace analysis. Across the wider Digesters class, laboratories also deploy it for environmental soil, sediment and sludge analysis, food and feed elemental analysis and metals and alloy trace analysis.
Which standards and certifications apply?
Relevant standards and methods include EPA 3051A, EPA 3050B, EPA 200.2, ISO 11466 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Add acids in a fume hood and use the protective equipment specified for the reagent, including face and eye protection, gloves and an acid-resistant apron. Do not exceed the rated temperature or pressure of the vessels, and allow closed vessels to cool before opening to avoid acid spray. Digest a reagent blank and, where required, a certified reference material to verify recovery and completeness. Check vessels for scratches and damage, and replace them on schedule, since worn vessels may fail. Follow the applicable method, such as EPA 3051A, EPA 3050B, ISO 11466 or the Kjeldahl procedure, and record all temperatures, times and reagent volumes.
How do I select the right Microwave Digestion System?
Choose a microwave digestion system for difficult matrices, volatile elements or low detection limits. Confirm the temperature and pressure ratings meet the method, the vessel material suits the acids, and the number of positions matches the workload. Verify that temperature and pressure are monitored in every vessel or in a representative one, and that cooling is adequate.
How does it compare with other Digesters variants?
Choose a digester according to the sample matrix, the analytes and the required detection limits. Block digestion suits routine, high-throughput work with simple matrices and volatile analytes that are retained, such as nitrogen and some metals. Kjeldahl systems are specific to nitrogen and protein determination. Closed-vessel and microwave digestion suit difficult matrices, volatile elements and low detection limits, because they reach higher temperatures and retain volatiles. Automated systems add reagent dosing, heating programmes and cooling for reproducibility. Confirm the vessel material and pressure rating suit the acids used, the temperature reaches the method requirement, and the throughput matches the workload.
Full specifications
| Max temperature | Up to 260 °C |
|---|---|
| Max pressure | Up to 100 bar |
| Vessel volume | 50–100 mL |
| Vessel positions | 6–40 |
| Microwave power | 1,000–1,600 W |
| Vessel material | PTFE-TFM |
| Temperature sensor | In-vessel, fiber optic |
| Pressure control | Automatic venting |
| Cooling | Forced air or water |
| Power supply | 220–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Trace element analysis in environmental samples
- Food and feed heavy metal testing
- Geological and metallurgical sample digestion
- Pharmaceutical and biological trace analysis
Key features
- Sealed pressure-rated vessels with microwave heating
- Rapid heating to high temperature
- Retention of volatile elements
- Programmable pressure and temperature control
- Rotating turntable for uniform heating
Frequently asked questions about Microwave Digestion System
Sealing allows the acid to be heated above its atmospheric boiling point, which greatly speeds decomposition, and prevents volatile elements such as mercury and arsenic from escaping. The sealed vessel also reduces acid consumption and cross-contamination from the laboratory environment.
Vessels are rated for a maximum pressure and the instrument monitors pressure, venting automatically if it rises too high. Reaction gases from oxidising acids are the main pressure source, so sample mass and acid volume are limited. Vessels are cooled before opening to avoid acid spray.
Yes, many systems automate power programmes, temperature ramping, cooling and venting, and some handle vessel loading and acid addition. Automation improves reproducibility and safety, but reaction conditions still need validation for each matrix and the vessels must be inspected regularly.
Open digestion heats the sample in a vessel open to the atmosphere, which is simple but can lose volatile elements and needs more acid and time. Closed digestion seals the sample and acid in a pressure vessel, so higher temperatures are reached, volatiles are retained and less acid is used.
Nitric acid is the most common, often with hydrochloric acid to form aqua regia, or with hydrogen peroxide to improve oxidation. Hydrofluoric acid is used for silicate matrices, and sulfuric acid for Kjeldahl digestion. The choice depends on the matrix, the analytes and the vessel material.
A reagent blank undergoes the same digestion with the same acids and vessels but without sample. It shows the contribution of reagents and vessels to the measured signal, allowing that background to be subtracted and confirming that contamination from the procedure is acceptably low.