Kjeldahl Digestion System
凯氏消解系统
- SKU DIG-0003
- Digesters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient to 450 °C |
|---|---|
| Block positions | 6–40 tubes |
| Tube volume | 100–250 mL |
| Catalyst | Copper or selenium tablets |
| Salt | Potassium sulfate |
| Acid | Sulfuric acid, concentrated |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA 3051A, EPA 3050B, EPA 200.2
What is the Kjeldahl Digestion System?
A Kjeldahl digestion system converts nitrogen in a sample to ammonium sulfate using sulfuric acid and heat. It is the standard preparation step for protein and nitrogen determination in food, feed and water.
What is the Kjeldahl Digestion System?
A Kjeldahl digestion system converts nitrogen in a sample to ammonium sulfate using sulfuric acid and heat. It is the standard preparation step for protein and nitrogen determination in food, feed and water.
Overview
A Kjeldahl digestion system heats the sample with concentrated sulfuric acid, a salt such as potassium sulfate and a catalyst to raise the boiling point and speed the reaction. Organic nitrogen is converted to ammonium sulfate, and the digest is then made alkaline and distilled, with the ammonia collected and titrated. The digestion block holds multiple tubes with an exhaust manifold that removes acid fumes, and a scrubber neutralises them. Digestion temperature, catalyst choice and time determine completeness, and a reagent blank and reference material are used to verify the method. It is the reference preparation for protein determination by nitrogen content.
How does it work?
Digestion breaks down a sample matrix so that the analytes of interest enter solution in a measurable form. In block digestion, tubes or vessels are heated on a temperature-controlled aluminium block and acid is added, often with reflux. In Kjeldahl digestion, the sample is heated with sulfuric acid and a catalyst to convert nitrogen compounds to ammonium sulfate. In closed-vessel and microwave digestion, acid and sample are sealed in a pressure-rated vessel and heated rapidly, so higher temperatures are reached, volatiles are retained and less acid and time are needed. Reagent choice, temperature, pressure and time determine completeness, and the resulting digest is diluted and filtered before measurement.
What are the key features?
- Heating block with multiple digestion tubes
- Acid fume exhaust and scrubber
- Catalyst and salt addition for complete digestion
- Programmable temperature and time
- Standard preparation for nitrogen determination
What are the technical specifications?
A typical kjeldahl digestion system configuration offers temperature range of Ambient to 450 °C, block positions of 6–40 tubes, tube volume of 100–250 mL, catalyst of Copper or selenium tablets, salt of Potassium sulfate and acid of Sulfuric acid, concentrated. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Kjeldahl Digestion System is used in protein determination in food and feed, nitrogen analysis in water and wastewater, fertiliser and soil nitrogen testing and pharmaceutical and agricultural analysis. Across the wider Digesters class, laboratories also deploy it for environmental soil, sediment and sludge analysis, food and feed elemental analysis and metals and alloy trace analysis.
Which standards and certifications apply?
Relevant standards and methods include EPA 3051A, EPA 3050B, EPA 200.2, ISO 11466 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Add acids in a fume hood and use the protective equipment specified for the reagent, including face and eye protection, gloves and an acid-resistant apron. Do not exceed the rated temperature or pressure of the vessels, and allow closed vessels to cool before opening to avoid acid spray. Digest a reagent blank and, where required, a certified reference material to verify recovery and completeness. Check vessels for scratches and damage, and replace them on schedule, since worn vessels may fail. Follow the applicable method, such as EPA 3051A, EPA 3050B, ISO 11466 or the Kjeldahl procedure, and record all temperatures, times and reagent volumes.
How do I select the right Kjeldahl Digestion System?
Choose a Kjeldahl digestion system for nitrogen and protein determination. Confirm the temperature range suits the catalyst and salt mixture, the number of positions matches the workload, and the exhaust and scrubber handle sulfuric acid fumes. Consider a complete Kjeldahl line with distillation and titration for a fully integrated workflow.
How does it compare with other Digesters variants?
Choose a digester according to the sample matrix, the analytes and the required detection limits. Block digestion suits routine, high-throughput work with simple matrices and volatile analytes that are retained, such as nitrogen and some metals. Kjeldahl systems are specific to nitrogen and protein determination. Closed-vessel and microwave digestion suit difficult matrices, volatile elements and low detection limits, because they reach higher temperatures and retain volatiles. Automated systems add reagent dosing, heating programmes and cooling for reproducibility. Confirm the vessel material and pressure rating suit the acids used, the temperature reaches the method requirement, and the throughput matches the workload.
Full specifications
| Temperature range | Ambient to 450 °C |
|---|---|
| Block positions | 6–40 tubes |
| Tube volume | 100–250 mL |
| Catalyst | Copper or selenium tablets |
| Salt | Potassium sulfate |
| Acid | Sulfuric acid, concentrated |
| Exhaust system | Manifold with scrubber |
| Programmes | Multi-step ramping |
| Temperature sensor | PT1000 |
| Power supply | 220–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein determination in food and feed
- Nitrogen analysis in water and wastewater
- Fertiliser and soil nitrogen testing
- Pharmaceutical and agricultural analysis
Key features
- Heating block with multiple digestion tubes
- Acid fume exhaust and scrubber
- Catalyst and salt addition for complete digestion
- Programmable temperature and time
- Standard preparation for nitrogen determination
Frequently asked questions about Kjeldahl Digestion System
Potassium sulfate raises the boiling point of the sulfuric acid so digestion proceeds at a higher temperature, while a catalyst such as copper or selenium speeds the oxidation of organic matter. Together they shorten digestion time and ensure complete conversion of nitrogen to ammonium sulfate.
The digest is made alkaline to release ammonia, which is distilled into a boric acid or standard acid solution and then titrated or measured colorimetrically. The nitrogen content is calculated from the titration, and multiplying by a factor gives the protein content for the food or feed type.
Kjeldahl digestion releases sulfur trioxide and acid fumes at high temperature, which are corrosive and hazardous. An exhaust manifold draws the fumes away and a scrubber neutralises them with an alkaline solution, protecting the operator and the laboratory and meeting safety requirements.
Open digestion heats the sample in a vessel open to the atmosphere, which is simple but can lose volatile elements and needs more acid and time. Closed digestion seals the sample and acid in a pressure vessel, so higher temperatures are reached, volatiles are retained and less acid is used.
Nitric acid is the most common, often with hydrochloric acid to form aqua regia, or with hydrogen peroxide to improve oxidation. Hydrofluoric acid is used for silicate matrices, and sulfuric acid for Kjeldahl digestion. The choice depends on the matrix, the analytes and the vessel material.
A reagent blank undergoes the same digestion with the same acids and vessels but without sample. It shows the contribution of reagents and vessels to the measured signal, allowing that background to be subtracted and confirming that contamination from the procedure is acceptably low.