Block Digestion System
石墨消解系统
- SKU DIG-0001
- Digesters
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient to 250 °C |
|---|---|
| Temperature stability | ±1 °C |
| Block positions | 20–60 tubes |
| Tube volume | 50–250 mL |
| Block material | Graphite |
| Programmes | Multi-step, 10 stages |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EPA 3051A, EPA 3050B, EPA 200.2
What is the Block Digestion System?
A block digestion system heats samples and acid in tubes on a temperature-controlled block. It is a rugged, high-throughput choice for routine open digestion of environmental, food and agricultural samples in the laboratory.
What is the Block Digestion System?
A block digestion system heats samples and acid in tubes on a temperature-controlled block. It is a rugged, high-throughput choice for routine open digestion of environmental, food and agricultural samples in the laboratory.
Overview
A block digestion system comprises a graphite or aluminium heating block with drilled wells that hold digestion tubes, a temperature controller and often a reflux or exhaust system. Acid and sample are placed in the tubes and heated according to a programme, and vapours are removed by a fume hood, scrubber or exhaust manifold. Graphite blocks heat evenly and hold temperature well, so many samples can be digested in parallel with good reproducibility. The design is simple, robust and suited to routine open digestion such as EPA 3050B and Kjeldahl procedures, where volatile loss is acceptable or analytes are retained. Temperature programming and time control are the main operating variables.
How does it work?
Digestion breaks down a sample matrix so that the analytes of interest enter solution in a measurable form. In block digestion, tubes or vessels are heated on a temperature-controlled aluminium block and acid is added, often with reflux. In Kjeldahl digestion, the sample is heated with sulfuric acid and a catalyst to convert nitrogen compounds to ammonium sulfate. In closed-vessel and microwave digestion, acid and sample are sealed in a pressure-rated vessel and heated rapidly, so higher temperatures are reached, volatiles are retained and less acid and time are needed. Reagent choice, temperature, pressure and time determine completeness, and the resulting digest is diluted and filtered before measurement.
What are the key features?
- Graphite or aluminium heating block with tube wells
- Programmable temperature and time control
- Parallel digestion of many samples
- Fume exhaust or scrubber connection
- Simple, robust and high-throughput
What are the technical specifications?
A typical block digestion system configuration offers temperature range of Ambient to 250 °C, temperature stability of ±1 °C, block positions of 20–60 tubes, tube volume of 50–250 mL, block material of Graphite and programmes of Multi-step, 10 stages. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Block Digestion System is used in environmental soil and sludge digestion, kjeldahl nitrogen determination, food and feed elemental analysis and agricultural and plant sample preparation. Across the wider Digesters class, laboratories also deploy it for environmental soil, sediment and sludge analysis, food and feed elemental analysis and metals and alloy trace analysis.
Which standards and certifications apply?
Relevant standards and methods include EPA 3051A, EPA 3050B, EPA 200.2, ISO 11466 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Add acids in a fume hood and use the protective equipment specified for the reagent, including face and eye protection, gloves and an acid-resistant apron. Do not exceed the rated temperature or pressure of the vessels, and allow closed vessels to cool before opening to avoid acid spray. Digest a reagent blank and, where required, a certified reference material to verify recovery and completeness. Check vessels for scratches and damage, and replace them on schedule, since worn vessels may fail. Follow the applicable method, such as EPA 3051A, EPA 3050B, ISO 11466 or the Kjeldahl procedure, and record all temperatures, times and reagent volumes.
How do I select the right Block Digestion System?
Choose a block digestion system for routine, high-throughput open digestion with good temperature control. Confirm the temperature range and stability meet the method, the number of positions matches the workload, and the exhaustion system handles the acid vapours. Consider glass or PTFE tubes and a scrubber for acid recovery.
How does it compare with other Digesters variants?
Choose a digester according to the sample matrix, the analytes and the required detection limits. Block digestion suits routine, high-throughput work with simple matrices and volatile analytes that are retained, such as nitrogen and some metals. Kjeldahl systems are specific to nitrogen and protein determination. Closed-vessel and microwave digestion suit difficult matrices, volatile elements and low detection limits, because they reach higher temperatures and retain volatiles. Automated systems add reagent dosing, heating programmes and cooling for reproducibility. Confirm the vessel material and pressure rating suit the acids used, the temperature reaches the method requirement, and the throughput matches the workload.
Full specifications
| Temperature range | Ambient to 250 °C |
|---|---|
| Temperature stability | ±1 °C |
| Block positions | 20–60 tubes |
| Tube volume | 50–250 mL |
| Block material | Graphite |
| Programmes | Multi-step, 10 stages |
| Temperature sensor | PT1000 |
| Exhaust connection | Scrubber or fume hood |
| Display | Digital with timer |
| Power supply | 220–240 V AC |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Environmental soil and sludge digestion
- Kjeldahl nitrogen determination
- Food and feed elemental analysis
- Agricultural and plant sample preparation
Key features
- Graphite or aluminium heating block with tube wells
- Programmable temperature and time control
- Parallel digestion of many samples
- Fume exhaust or scrubber connection
- Simple, robust and high-throughput
Frequently asked questions about Block Digestion System
Graphite conducts heat well and has high thermal mass, so the block heats uniformly and holds temperature when cold tubes are inserted. This gives consistent digestion across all positions and good reproducibility between samples and batches.
Open block digestion can lose volatile elements such as mercury and arsenic unless a reflux or closed tube is used. For these analytes, closed-vessel or microwave digestion is preferred because the sealed vessel retains the volatiles in solution.
Typical units hold between twenty and sixty tubes, allowing parallel digestion of a full batch. Throughput also depends on the heating programme, cooling time and the number of operators. Consistency across positions should be verified when the instrument is installed.
Open digestion heats the sample in a vessel open to the atmosphere, which is simple but can lose volatile elements and needs more acid and time. Closed digestion seals the sample and acid in a pressure vessel, so higher temperatures are reached, volatiles are retained and less acid is used.
Nitric acid is the most common, often with hydrochloric acid to form aqua regia, or with hydrogen peroxide to improve oxidation. Hydrofluoric acid is used for silicate matrices, and sulfuric acid for Kjeldahl digestion. The choice depends on the matrix, the analytes and the vessel material.
A reagent blank undergoes the same digestion with the same acids and vessels but without sample. It shows the contribution of reagents and vessels to the measured signal, allowing that background to be subtracted and confirming that contamination from the procedure is acceptably low.
Related models