HbA1c Analyzer (Ion-Exchange HPLC)

糖化血红蛋白分析仪(离子交换 HPLC)

  • SKU DIA-0002
  • Diagnostic Analyzers
  • CE (to be confirmed)
  • NGSP certification (to be confirmed)
  • ISO 13485 quality system (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
MethodCation-exchange HPLC
Measuring range3.0–20.0% HbA1c (NGSP)
Throughput30–70 samples/h
Sample volume5–20 µL whole blood
Precision (CV)≤ 2% at 5.5–9% HbA1c
Detection wavelengths415 nm / 690 nm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, CLSI C46

What is the HbA1c Analyzer (Ion-Exchange HPLC)?

An ion-exchange HPLC HbA1c analyzer separates glycated hemoglobin from other hemoglobin fractions and quantifies it by absorbance at 415 nm. It is the preferred choice for laboratories needing standardized HbA1c and the ability to detect common hemoglobin variants.

What is the HbA1c Analyzer (Ion-Exchange HPLC)?

An ion-exchange HPLC HbA1c analyzer separates glycated hemoglobin from other hemoglobin fractions and quantifies it by absorbance at 415 nm. It is the preferred choice for laboratories needing standardized HbA1c and the ability to detect common hemoglobin variants.

Overview

This variant pumps a hemolysate through a cation-exchange column using a step or gradient of buffers of increasing ionic strength, eluting hemoglobin fractions A1a, A1b, F, LA1c, A1c, A0 and variants at characteristic retention times. A dual-wavelength detector at 415 and 690 nm quantifies peaks, and the software reports HbA1c in NGSP percent and IFCC mmol/mol. Throughput is typically 30 to 70 samples per hour, with run times of about 1 minute per sample on fast systems. Automatic sampling from primary tubes, hemolysis on board and barcode reading reduce manual steps. Chromatograms allow visual detection of HbS, HbC and HbF, which can interfere with some immunoassays. Column life is about 1,000 to 3,000 injections.

How does it work?

Diagnostic analyzers combine a sample handling system, a reaction or sensing chamber and a detector specific to the measurand. Blood gas analyzers use ion-selective, Clark-type oxygen and Severinghaus-type carbon dioxide electrodes. HbA1c analyzers separate hemoglobin fractions by cation-exchange HPLC and detect them at 415 nm. Specific protein analyzers measure light scattering or turbidity produced when antibody-coated particles bind a protein, using nephelometry or immunoturbidimetry. Blood culture systems monitor carbon dioxide production by colorimetric or fluorescent sensors inside bottles to flag microbial growth. Identification and susceptibility systems measure turbidity and growth kinetics in panels containing substrates or antibiotics. Calibration with standards and periodic quality control ensure that results remain traceable and within acceptance limits.

What are the key features?

  • Cation-exchange HPLC separation of hemoglobin fractions and variants
  • Dual-wavelength detection at 415 and 690 nm
  • Automatic sampling from primary tubes with barcode reading
  • Reporting in NGSP percent and IFCC mmol/mol units
  • Chromatogram display for hemoglobin variant recognition
  • Automatic calibration and quality control tracking

What are the technical specifications?

A typical hba1c analyzer (ion-exchange hplc) configuration offers method of Cation-exchange HPLC, measuring range of 3.0–20.0% HbA1c (NGSP), throughput of 30–70 samples/h, sample volume of 5–20 µL whole blood, precision (CV) of ≤ 2% at 5.5–9% HbA1c and detection wavelengths of 415 nm / 690 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The HbA1c Analyzer (Ion-Exchange HPLC) is used in diabetes diagnosis and monitoring, hospital endocrinology laboratory, health check centers and hemoglobin variant screening. Across the wider Diagnostic Analyzers class, laboratories also deploy it for critical care blood gas monitoring, diabetes control monitoring and inflammation and immune protein testing.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, IEC 61010-2-101, CLSI C46, CLSI EP15, ISO 18113-1, ISO 15197, CLSI M47 and CLSI M07. Certification candidates for this model are CE, NGSP certification and ISO 13485 quality system; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers on stable benches with controlled temperature, stable power and adequate ventilation. Follow manufacturer schedules for electrode or column replacement, reagent pack changes and waste handling, and treat all specimens and waste as potentially infectious. Run quality control at defined intervals, participate in external quality assessment and verify performance on installation according to CLSI EP15. Blood gas analyzers require regular membrane and electrode maintenance and proper sample handling to avoid air bubbles. Blood culture instruments need a clean, vibration-free environment. Document calibration, maintenance and training under the laboratory quality system in line with ISO 15189, and plan service and spare parts support.

How do I select the right HbA1c Analyzer (Ion-Exchange HPLC)?

Select HPLC HbA1c analyzers for medium to large laboratories needing variant detection and high precision. Specify expected daily samples, NGSP certification needs, column and reagent supply, tube handling, LIS interface and whether variant reporting is required in the RFQ.

How does it compare with other Diagnostic Analyzers variants?

Choose the analyzer by the measurand and the clinical setting. Blood gas analyzers for critical care should provide results in under two minutes from small sample volumes, with integrated co-oximetry and electrolytes if needed. For diabetes programs, HbA1c analyzers should demonstrate traceability to IFCC and NGSP and throughput matching the clinic. Specific protein analyzers differ in menu, sample dilution and calibration stability. Microbiology systems should match bottle capacity to blood culture volume. Compare reagent and consumable availability, maintenance demands, onboard calibration, LIS connectivity and operator training. Request evidence such as precision, interference testing and method comparison, and confirm the registration status of reagents in your market.

Full specifications

Full specifications
MethodCation-exchange HPLC
Measuring range3.0–20.0% HbA1c (NGSP)
Throughput30–70 samples/h
Sample volume5–20 µL whole blood
Precision (CV)≤ 2% at 5.5–9% HbA1c
Detection wavelengths415 nm / 690 nm
Column life≈ 1,000–3,000 injections
TraceabilityIFCC reference method, NGSP aligned
Sample loadingRacks of 10, up to 100 tubes
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Diabetes diagnosis and monitoring
  • Hospital endocrinology laboratory
  • Health check centers
  • Hemoglobin variant screening

Key features

  • Cation-exchange HPLC separation of hemoglobin fractions and variants
  • Dual-wavelength detection at 415 and 690 nm
  • Automatic sampling from primary tubes with barcode reading
  • Reporting in NGSP percent and IFCC mmol/mol units
  • Chromatogram display for hemoglobin variant recognition
  • Automatic calibration and quality control tracking

Frequently asked questions about HbA1c Analyzer (Ion-Exchange HPLC)

Yes, ion-exchange chromatograms show abnormal peaks for common variants such as HbS, HbC, HbE and HbD and elevated HbF. Analysts review the chromatogram to decide whether the HbA1c value is reliable or whether an alternative method should be used.

Request a quotation for the HbA1c Analyzer (Ion-Exchange HPLC)

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote