Blood Gas and Electrolyte Analyzer

血气电解质分析仪

  • SKU DIA-0001
  • Diagnostic Analyzers
  • CE (to be confirmed)
  • ISO 13485 quality system (to be confirmed)
  • NMPA registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Sample volume65–100 µL
Analysis time45–90 s
pH range6.500–8.000
pCO2 range5–250 mmHg
pO2 range0–800 mmHg
Na+ range85–200 mmol/L
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, CLSI C46

What is the Blood Gas and Electrolyte Analyzer?

A blood gas and electrolyte analyzer measures pH, pCO2 and pO2 together with sodium, potassium, chloride, calcium and often glucose and lactate in whole blood. It is the right choice for intensive care, operating rooms, emergency departments and neonatal units needing results within minutes.

What is the Blood Gas and Electrolyte Analyzer?

A blood gas and electrolyte analyzer measures pH, pCO2 and pO2 together with sodium, potassium, chloride, calcium and often glucose and lactate in whole blood. It is the right choice for intensive care, operating rooms, emergency departments and neonatal units needing results within minutes.

Overview

This variant uses a measurement cartridge or sensor module containing ion-selective electrodes, pH glass electrode, Severinghaus-type pCO2 sensor and Clark-type pO2 sensor. Sample volumes are typically 65 to 100 microliters, with analysis in 45 to 90 seconds. An integrated co-oximeter can report total hemoglobin, oxyhemoglobin, carboxyhemoglobin and methemoglobin using multi-wavelength spectrophotometry. Calculated parameters include bicarbonate, base excess and oxygen saturation. Compact models run on single-use or multi-use cartridges with onboard calibrators, which minimizes maintenance. Connectivity and operator lockout features support point-of-care deployment under laboratory supervision. Sensors need periodic replacement, and electrodes must be calibrated automatically at programmed intervals. Sample handling must avoid air bubbles to keep gas results accurate.

How does it work?

Diagnostic analyzers combine a sample handling system, a reaction or sensing chamber and a detector specific to the measurand. Blood gas analyzers use ion-selective, Clark-type oxygen and Severinghaus-type carbon dioxide electrodes. HbA1c analyzers separate hemoglobin fractions by cation-exchange HPLC and detect them at 415 nm. Specific protein analyzers measure light scattering or turbidity produced when antibody-coated particles bind a protein, using nephelometry or immunoturbidimetry. Blood culture systems monitor carbon dioxide production by colorimetric or fluorescent sensors inside bottles to flag microbial growth. Identification and susceptibility systems measure turbidity and growth kinetics in panels containing substrates or antibiotics. Calibration with standards and periodic quality control ensure that results remain traceable and within acceptance limits.

What are the key features?

  • pH, pCO2 and pO2 sensors with calculated bicarbonate and base excess
  • Electrolyte measurement of Na, K, Cl and ionized calcium
  • Optional co-oximetry for total hemoglobin and hemoglobin derivatives
  • Sample volume of 65–100 µL with result in under 90 seconds
  • Automatic calibration and quality control with operator lockout
  • Connectivity to hospital and laboratory information systems

What are the technical specifications?

A typical blood gas and electrolyte analyzer configuration offers sample volume of 65–100 µL, analysis time of 45–90 s, pH range of 6.500–8.000, pCO2 range of 5–250 mmHg, pO2 range of 0–800 mmHg and na+ range of 85–200 mmol/L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Blood Gas and Electrolyte Analyzer is used in intensive care units, operating rooms, emergency departments and neonatal units. Across the wider Diagnostic Analyzers class, laboratories also deploy it for critical care blood gas monitoring, diabetes control monitoring and inflammation and immune protein testing.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, IEC 61010-2-101, CLSI C46, CLSI EP15, ISO 18113-1, ISO 15197, CLSI M47 and CLSI M07. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install analyzers on stable benches with controlled temperature, stable power and adequate ventilation. Follow manufacturer schedules for electrode or column replacement, reagent pack changes and waste handling, and treat all specimens and waste as potentially infectious. Run quality control at defined intervals, participate in external quality assessment and verify performance on installation according to CLSI EP15. Blood gas analyzers require regular membrane and electrode maintenance and proper sample handling to avoid air bubbles. Blood culture instruments need a clean, vibration-free environment. Document calibration, maintenance and training under the laboratory quality system in line with ISO 15189, and plan service and spare parts support.

How do I select the right Blood Gas and Electrolyte Analyzer?

Choose this variant when arterial blood gases and electrolytes are needed within minutes. Specify the parameter menu, co-oximetry, cartridge life, sample volume, calibration method, daily sample load, connectivity and point-of-care or central laboratory deployment in the RFQ.

How does it compare with other Diagnostic Analyzers variants?

Choose the analyzer by the measurand and the clinical setting. Blood gas analyzers for critical care should provide results in under two minutes from small sample volumes, with integrated co-oximetry and electrolytes if needed. For diabetes programs, HbA1c analyzers should demonstrate traceability to IFCC and NGSP and throughput matching the clinic. Specific protein analyzers differ in menu, sample dilution and calibration stability. Microbiology systems should match bottle capacity to blood culture volume. Compare reagent and consumable availability, maintenance demands, onboard calibration, LIS connectivity and operator training. Request evidence such as precision, interference testing and method comparison, and confirm the registration status of reagents in your market.

Full specifications

Full specifications
Sample volume65–100 µL
Analysis time45–90 s
pH range6.500–8.000
pCO2 range5–250 mmHg
pO2 range0–800 mmHg
Na+ range85–200 mmol/L
K+ range1.0–12.0 mmol/L
Sample typesArterial, venous and capillary whole blood
CalibrationAutomatic, 1-point and 2-point
Data storage≥ 10,000 results

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Intensive care units
  • Operating rooms
  • Emergency departments
  • Neonatal units

Key features

  • pH, pCO2 and pO2 sensors with calculated bicarbonate and base excess
  • Electrolyte measurement of Na, K, Cl and ionized calcium
  • Optional co-oximetry for total hemoglobin and hemoglobin derivatives
  • Sample volume of 65–100 µL with result in under 90 seconds
  • Automatic calibration and quality control with operator lockout
  • Connectivity to hospital and laboratory information systems

Frequently asked questions about Blood Gas and Electrolyte Analyzer

Heparinized arterial, venous or capillary whole blood is used, collected in balanced heparin syringes or capillaries. Samples should be analyzed within 10 to 15 minutes, free of air bubbles and mixed well, to avoid changes in pO2, pCO2 and lactate.

Request a quotation for the Blood Gas and Electrolyte Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote