Time-Lapse Cell Monitoring System

活细胞时间序列监测系统

  • SKU CUM-0004
  • Culture Monitoring
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Magnification4x, 10x and 20x objectives typical
Imaging channelsBrightfield, phase contrast and 1–4 fluorescence
Imaging intervalprogrammable, 1 min to 24 h
Positions per runup to 50 (model dependent)
Environmental controlProvided by the host incubator at 37 °C and 5% CO2
Run durationhours to several weeks
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 14644-1

What is the Time-Lapse Cell Monitoring System?

A time-lapse cell monitoring system keeps a culture at 37 °C with controlled CO2 while capturing images at set intervals, producing a film of growth, migration, death and morphological change inside the incubator.

What is the Time-Lapse Cell Monitoring System?

A time-lapse cell monitoring system keeps a culture at 37 °C with controlled CO2 while capturing images at set intervals, producing a film of growth, migration, death and morphological change inside the incubator.

Overview

The system combines a microscope unit small enough for the incubator, controlled illumination, and software that builds a time-lapse sequence from repeated acquisitions at multiple positions. Environmental control is supplied by the incubator itself, which avoids the focus drift and evaporation of stage-top chambers, and the vessel is never handled during the experiment. Frames can be acquired in brightfield, phase contrast and one or more fluorescence channels, with low light doses and intervals from minutes to hours. Analysis tools derive confluence, growth rate, cell count, migration distance and event timing such as mitosis or apoptosis, and can track individual cells. Long experiments generate large data volumes, so storage and review workflows should be planned before starting.

How does it work?

Monitoring methods translate a physical or chemical property of the culture into a usable signal. Imaging systems illuminate the culture surface and estimate confluence from the fraction of the area occupied by cells, or count fluorescent objects to give viable cell density. Capacitance probes apply a radio-frequency field across the culture; viable cells with intact membranes behave as polarisable particles whose signal is proportional to viable cell volume, while dead cells and debris contribute little. Dissolved oxygen is measured with electrochemical or optical sensors, and pH with glass or optical sensors, both of which can be steam-sterilised for bioreactor use. Metabolite analysers use enzyme-based or optical assays to quantify glucose, lactate, glutamine and ammonia in culture samples. Raman spectroscopy adds in-line multi-component measurement when a chemometric model has been calibrated for the process.

What are the key features?

  • Incubator-compatible microscope unit with controlled illumination
  • Multi-position imaging with programmable intervals
  • Brightfield, phase contrast and fluorescence channels
  • Analysis of confluence, growth rate, migration and events
  • Low phototoxicity settings for multi-day experiments
  • Automatic focus adjustment across long sequences

What are the technical specifications?

A typical time-lapse cell monitoring system configuration offers magnification of 4x, 10x and 20x objectives typical, imaging channels of Brightfield, phase contrast and 1–4 fluorescence, imaging interval of programmable, 1 min to 24 h, positions per run of up to 50 (model dependent), environmental control of Provided by the host incubator at 37 °C and 5% CO2 and run duration of hours to several weeks. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Time-Lapse Cell Monitoring System is used in proliferation and growth rate measurement, migration, wound healing and invasion assays, apoptosis and cell death kinetics and stem cell and organoid development tracking. Across the wider Culture Monitoring class, laboratories also deploy it for feeding and harvest timing decisions, bioreactor process control and scale-up and contamination and stress detection.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 14644-1, USP <1046> and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate each sensor against the reference method used in your laboratory, and record the calibration coefficients, since drift differs between probe types and affects decisions. For optical sensors, check the excitation wavelength and the dye's sensitivity to pH, ionic strength and temperature, which must be matched to the culture conditions. Capacitance probes require a defined conductivity window, so the medium formulation cannot change without re-validation. Sampling for metabolite analysis should be consistent in timing and dilution, and the analyser should be checked with standards daily. Clean and sterilise probes according to the manufacturer's instructions, since residues from previous runs cause drift, and replace consumable sensors at the recommended interval rather than at failure. Keep trend data rather than single values, because rates of change are usually more informative.

How do I select the right Time-Lapse Cell Monitoring System?

Select a time-lapse system when the timing of events matters, when the same culture must be followed repeatedly, or when handling disruption would compromise the result. Specify magnification, channels, interval range, position count, autofocus and data storage planning.

How does it compare with other Culture Monitoring variants?

Decide what decision the data must support. If the question is when to passage or harvest an adherent culture, automated confluence imaging is sufficient and simple. If viable cell density drives feeding or infection timing, capacitance biomass monitoring provides a real-time signal without sampling. For process control in a bioreactor, dissolved oxygen, pH and temperature probes are essential, and metabolite analysis adds the information needed to adjust perfusion or feed rates. Raman or near-infrared in-line analysers are justified only when the modelling effort can be sustained and the process runs often enough to benefit. Check measurement range and accuracy, response time, sterilisation method, whether the sensor contacts the culture, calibration and drift behaviour, integration with control software, and the frequency of consumable or probe replacement.

Full specifications

Full specifications
Magnification4x, 10x and 20x objectives typical
Imaging channelsBrightfield, phase contrast and 1–4 fluorescence
Imaging intervalprogrammable, 1 min to 24 h
Positions per runup to 50 (model dependent)
Environmental controlProvided by the host incubator at 37 °C and 5% CO2
Run durationhours to several weeks
CameraMonochrome CMOS, 5–20 MP
Data volumeseveral GB per day depending on settings
Light sourceLED with low-intensity modes
Dimensions (W x D x H)approx. 300 x 300 x 300 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Proliferation and growth rate measurement
  • Migration, wound healing and invasion assays
  • Apoptosis and cell death kinetics
  • Stem cell and organoid development tracking

Key features

  • Incubator-compatible microscope unit with controlled illumination
  • Multi-position imaging with programmable intervals
  • Brightfield, phase contrast and fluorescence channels
  • Analysis of confluence, growth rate, migration and events
  • Low phototoxicity settings for multi-day experiments
  • Automatic focus adjustment across long sequences

Frequently asked questions about Time-Lapse Cell Monitoring System

Environmental conditions stay constant and the vessel is never moved, so focus is stable and evaporation is not increased. It also reduces contamination risk compared with transferring cultures to a microscope stage repeatedly.

Request a quotation for the Time-Lapse Cell Monitoring System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.