Lab Manufacturers China
Microfluidic Cell Culture System — product photo

Microfluidic Cell Culture System

微流控细胞培养系统

  • SKU CCS-0005
  • Cell Culture Systems
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Channel width100 µm–5 mm
Perfusion rate0.1–100 µL/min
Shear stress range0.001–2 Pa
Working volume1–500 µL per channel
Culture area0.1–5 cm² per chamber
MaterialPolydimethylsiloxane, glass or cyclic olefin polymer
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1

What is the Microfluidic Cell Culture System?

A microfluidic cell culture system grows cells in channels from 100 µm to a few millimetres wide, giving precise control of flow, shear stress and chemical gradients at low volume for mechanistic, organ-on-chip and screening studies.

What is the Microfluidic Cell Culture System?

A microfluidic cell culture system grows cells in channels from 100 µm to a few millimetres wide, giving precise control of flow, shear stress and chemical gradients at low volume for mechanistic, organ-on-chip and screening studies.

Overview

The chip or cartridge contains channels, chambers and sometimes membranes that separate two flow paths. Cells are seeded in a chamber and perfused with medium at flow rates of 0.1–100 µL/min, which sets the shear stress experienced by the cells and establishes gradients by controlled mixing of two streams. Integrated valves and pumps allow medium switching, chemical stimulation and sampling without disturbing the culture, and some devices add oxygen control or mechanical stretch to mimic breathing or peristalsis. Optical access through glass or optical-grade plastic permits microscopy and fluorescence imaging during the experiment. Because volumes are microlitres, reagent consumption is low and responses can be measured at single-cell resolution, though throughput per chip is small and bubbles must be carefully excluded.

How does it work?

Scaling cell culture means increasing the surface available for adherent cells or the volume in which suspension cells can grow, while maintaining oxygen, nutrients, pH and temperature. Spinner vessels stir medium with an impeller or a magnetic bar so that cells and microcarriers stay suspended and gas exchange occurs at the surface or through a sparger. Perfusion systems continuously replace medium, keeping nutrient concentrations stable and removing lactate and ammonia, which supports much higher cell densities than batch culture. Hollow fibre bioreactors grow cells on the outside or inside of semi-permeable fibres, supplying oxygen and nutrients by diffusion through the fibre wall and reaching densities of 10⁷–10⁸ cells per millilitre, but sampling cells for counting is difficult. Microfluidic systems keep cells in channels of 100 µm to a few millimetres, giving precise control of flow, gradients and shear at very small volumes. Automated platforms handle flasks or plates robotically, combining incubation, imaging and liquid handling.

What are the key features?

  • Channels and chambers from 100 µm to a few millimetres
  • Perfusion at 0.1–100 µL/min with defined shear stress
  • Controlled gradient generation by mixing two streams
  • Integrated valves or pumps for medium switching
  • Optical-grade material for live microscopy
  • Optional oxygen control or mechanical stretching

What are the technical specifications?

A typical microfluidic cell culture system configuration offers channel width of 100 µm–5 mm, perfusion rate of 0.1–100 µL/min, shear stress range of 0.001–2 Pa, working volume of 1–500 µL per channel, culture area of 0.1–5 cm² per chamber and material of Polydimethylsiloxane, glass or cyclic olefin polymer. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Microfluidic Cell Culture System is used in organ-on-chip and barrier models, chemotaxis and gradient response studies, cell migration and shear response research and low-volume compound testing on primary cells. Across the wider Cell Culture Systems class, laboratories also deploy it for suspension cell expansion for antibody production, microcarrier-based adherent cell culture and cell therapy process development.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, ISO 14644-1, USP <1046> and ISO 20387. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Start with the oxygen demand: at high density, dissolved oxygen becomes limiting before nutrients do, so sparging, headspace aeration or membrane oxygenation must be matched to the expected cell number. Check that shear from impellers or bubbles does not damage sensitive cells, and reduce agitation or add protective agents where necessary. Perfusion systems need validated tubing, sterile connections and pumps, and the medium feed rate must be tied to measured metabolite concentrations rather than a fixed schedule. Clean and sterilise vessels by autoclaving or single-use assemblies, and verify sterility with a control incubation before inoculating valuable cultures. Record inoculum density, agitation, gas flow, perfusion rate and sampling times so that runs can be compared, and validate the whole culture process against a reference method when results are reported.

How do I select the right Microfluidic Cell Culture System?

Select a microfluidic system when the experiment depends on defined flow, gradients or tissue-tissue interfaces, and when single-cell resolution matters more than throughput. Specify channel and chamber dimensions, flow and shear range, material and optical access, valve or pump configuration and temperature control.

How does it compare with other Cell Culture Systems variants?

Choose by scale, cell type and how much control the process needs. For a few flasks, an automated platform reduces hands-on time and improves consistency but does not increase capacity much. For suspension cells and microcarrier cultures, spinner vessels are the standard intermediate step, with volume from 100 mL to several litres. When cell density or product titre is the limiting factor, perfusion systems and hollow fibre bioreactors provide far higher densities per unit volume, at the cost of more complex control and harder cell sampling. Microfluidic systems suit mechanistic studies, organ-on-chip models and low-volume screening rather than production. Compare working volume, achievable cell density, oxygenation method, shear levels, perfusion control, sterility of fluid paths, automation level and the availability of validated protocols for your cell type.

Full specifications

Full specifications
Channel width100 µm–5 mm
Perfusion rate0.1–100 µL/min
Shear stress range0.001–2 Pa
Working volume1–500 µL per channel
Culture area0.1–5 cm² per chamber
MaterialPolydimethylsiloxane, glass or cyclic olefin polymer
Gradient generationTwo-stream mixing or membrane diffusion
Temperature control37 °C with heated stage or incubator
Imaging compatibilityBrightfield, phase and fluorescence microscopy
Dimensions (W x D x H)approx. 150 x 100 x 20 mm (chip)

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Organ-on-chip and barrier models
  • Chemotaxis and gradient response studies
  • Cell migration and shear response research
  • Low-volume compound testing on primary cells

Key features

  • Channels and chambers from 100 µm to a few millimetres
  • Perfusion at 0.1–100 µL/min with defined shear stress
  • Controlled gradient generation by mixing two streams
  • Integrated valves or pumps for medium switching
  • Optical-grade material for live microscopy
  • Optional oxygen control or mechanical stretching

Frequently asked questions about Microfluidic Cell Culture System

Shear depends on flow rate and channel geometry, so it is set by programming the pump. Typical values range from 0.001 Pa for static-like conditions to about 2 Pa for arterial-level shear, and the relationship should be calculated for each chip design.

Request a quotation for the Microfluidic Cell Culture System

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote