Automated Cryogenic Sample Storage System with Robotic Retrieval
带机器人取样的自动化低温样品储存系统
- SKU CSS-0004
- Cryogenic Storage Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Storage capacity | 50,000–500,000+ tubes |
|---|---|
| Storage temperature | −150°C to −190°C |
| Picking rate | Up to 100 tubes/h |
| Tube format | 0.5–2.0 mL, 2D coded |
| Box format | 81 or 100 positions, SBS footprint |
| Identification | Barcode and 2D code reader |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 21009-1, ISO 20387, IEC 61010-1
What is the Automated Cryogenic Sample Storage System with Robotic Retrieval?
An automated cryogenic sample storage system uses a robotic arm inside a cold chamber to store and retrieve individual tubes or boxes, typically at −150°C to −190°C. It is the right choice for very large collections where minimizing temperature excursions and tracking each vial matter more than purchase cost.
What is the Automated Cryogenic Sample Storage System with Robotic Retrieval?
An automated cryogenic sample storage system uses a robotic arm inside a cold chamber to store and retrieve individual tubes or boxes, typically at −150°C to −190°C. It is the right choice for very large collections where minimizing temperature excursions and tracking each vial matter more than purchase cost.
Overview
Automated systems house a robotic picker in a thermally controlled chamber, separate from the cold storage racks, so that operators request samples through software and the robot delivers a single tube or box without exposing the rest of the collection to ambient air. Storage is typically in vapor phase at about −150°C to −190°C, with capacities from 50,000 to more than 500,000 tubes. Barcode or 2D code readers identify boxes and individual tubes, and a database tracks location and access history. An airlock or transfer port limits heat entering when items are added or removed. Systems require integration with laboratory information management software, regular robot calibration, backup power and service contracts. Because storage and retrieval remain in cold conditions, the thermal history of untouched samples is protected, which benefits biobanks and pharmaceutical libraries with frequent picking.
How does it work?
A cryogenic storage system is a large vacuum-insulated liquid nitrogen vessel wrapped in control and safety instrumentation. Heat leaks through the vacuum jacket, lid and neck, and the resulting boil-off keeps the headspace near liquid nitrogen temperature. A level sensor, typically a differential pressure or capacitance probe, triggers a solenoid valve to admit liquid from a bulk supply and hold the level within a set band. In vapor-phase models, a rack holds boxes above the liquid, and temperature probes at several heights verify that the top box stays colder than −150°C. Isothermal designs use a vapor-tight inner liner so that the liquid is separated from the sample space and the vapor stays uniform. A controller logs temperature, level and lid-open events, and sends alarms through local sounders, relays or network connections.
What are the key features?
- Robotic picker retrieves single tubes or boxes without opening the whole store.
- Barcode or 2D code tracking records location and access history per tube.
- Airlock transfer port limits heat entering during sample loading.
- Vapor-phase chamber operates between −150°C and −190°C.
- Database and LIMS integration supports audit and inventory reporting.
- Modular capacity expansion allows growth from 50,000 to 500,000 tubes.
What are the technical specifications?
A typical automated cryogenic sample storage system with robotic retrieval configuration offers storage capacity of 50,000–500,000+ tubes, storage temperature of −150°C to −190°C, picking rate of Up to 100 tubes/h, tube format of 0.5–2.0 mL, 2D coded, box format of 81 or 100 positions, SBS footprint and identification of Barcode and 2D code reader. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Cryogenic Sample Storage System with Robotic Retrieval is used in national biobanks, pharmaceutical compound libraries, population cohort repositories and cell therapy large-scale storage. Across the wider Cryogenic Storage Systems class, laboratories also deploy it for biobank long-term storage, cell therapy master and working cell banks and cord blood and stem cell banking.
Which standards and certifications apply?
Relevant standards and methods include ISO 21009-1, ISO 20387, IEC 61010-1, GB/T 18442, EU Pressure Equipment Directive 2014/68/EU and ISO 21010. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Plan the installation before delivery: floor loading when filled can exceed one tonne, door and lift dimensions must pass the vessel, and a bulk liquid nitrogen line must be insulated and fitted with relief valves. Oxygen sensors should be located at low level and linked to an alarm and forced ventilation. Establish an alarm response plan and a backup vessel with spare capacity so that samples can be moved if a unit fails. Calibrate temperature and level probes at defined intervals, test alarms, and log all events. Minimize lid-open time during access and use inventory software to locate boxes before opening. Plan periodic vessel inspection and safety valve testing in line with local pressure-equipment rules.
How do I select the right Automated Cryogenic Sample Storage System with Robotic Retrieval?
Choose robotic storage when you handle more than about 100,000 samples with frequent single-tube picking. For smaller or rarely accessed collections, a manual vapor-phase system is more economical. In an RFQ, specify tube and box formats, capacity, picking throughput, LIMS interface, backup power and service coverage.
How does it compare with other Cryogenic Storage Systems variants?
Define the required phase first: vapor-phase or isothermal for clinical and cell therapy material, liquid phase where the lowest possible temperature matters and contamination risk is managed. Size storage in vials with spare capacity of 20–30%, and confirm the rack design, because box format drives the real vial count. Compare evaporation rate and nitrogen consumption, then the supply: bulk tank connection, pressure and pipe length. Specify monitoring depth, including temperature probes at several levels, level redundancy, remote alarm, data logging and audit trail for GMP-type work. Consider automated retrieval for very large collections, since it reduces open-lid time and sample warming. Check room size, ceiling height, floor load and ventilation, and plan oxygen sensors and emergency exhaust.
Full specifications
| Storage capacity | 50,000–500,000+ tubes |
|---|---|
| Storage temperature | −150°C to −190°C |
| Picking rate | Up to 100 tubes/h |
| Tube format | 0.5–2.0 mL, 2D coded |
| Box format | 81 or 100 positions, SBS footprint |
| Identification | Barcode and 2D code reader |
| Transfer chamber temperature | −80°C to −20°C |
| Liquid nitrogen consumption | 30–150 L/day |
| Software interface | LIMS via database or API |
| Power supply | 380 V AC three-phase, 50 Hz, 3–10 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- National biobanks
- Pharmaceutical compound libraries
- Population cohort repositories
- Cell therapy large-scale storage
Key features
- Robotic picker retrieves single tubes or boxes without opening the whole store.
- Barcode or 2D code tracking records location and access history per tube.
- Airlock transfer port limits heat entering during sample loading.
- Vapor-phase chamber operates between −150°C and −190°C.
- Database and LIMS integration supports audit and inventory reporting.
- Modular capacity expansion allows growth from 50,000 to 500,000 tubes.
Frequently asked questions about Automated Cryogenic Sample Storage System with Robotic Retrieval
Manual picking requires opening the lid and lifting racks, which warms neighboring samples. Automation isolates picking, keeping untouched boxes at storage temperature and improving traceability, at the cost of greater capital expense and maintenance.
Most use 0.5 to 2.0 mL externally threaded tubes with a 2D coded base, stored in SBS-format boxes of 81 or 100 positions. Non-standard vials, straws and bags usually require a different system, so confirm formats before purchase.
Well-designed systems include manual access ports and fault recovery modes so samples can be retrieved in an emergency, and a service contract with quick response. Plan for backup power, redundancy and periodic test retrievals.
A liquid nitrogen tank is mainly a passive insulated vessel, while a cryogenic storage system adds racks, level control, automatic filling, temperature monitoring and alarms for managed, traceable storage. Systems are designed for large, high-value collections rather than occasional use.
In isothermal storage, liquid nitrogen sits in a sealed jacket around the sample chamber, so vapor fills the space without direct liquid contact. Temperature differences are small, often within 10°C, and samples remain at about −190°C from top to bottom of the rack.
Consumption depends on size and opening frequency. A 200 L vapor-phase system typically uses roughly 1–3 L per day when lightly used, and large isothermal systems of 1,000+ L can use 10–30 L per day. Request the rated static rate and a typical usage estimate.