Benchtop Optical Contact Angle Goniometer with Motorized Dosing
带电动加液的台式光学接触角测角仪
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

纤维与粉体动态润湿用力学张力仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Balance resolution | 0.01 mg |
|---|---|
| Balance capacity | 210 g |
| Stage speed | 0.1–500 mm/min |
| Position resolution | 0.1 µm |
| Surface tension range | 1–2000 mN/m |
| Surface tension accuracy | ±0.1 mN/m |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D7334, ASTM D5946, ISO 19403-2
A microbalance-based instrument that measures the wetting force as a fiber, plate or powder column contacts a test liquid, from which contact angle is calculated with the Wilhelmy or Washburn method. It suits samples whose geometry prevents sessile-drop imaging.
A microbalance-based instrument that measures the wetting force as a fiber, plate or powder column contacts a test liquid, from which contact angle is calculated with the Wilhelmy or Washburn method. It suits samples whose geometry prevents sessile-drop imaging.
A force tensiometer suspends a sample from a high-precision microbalance with resolution of 0.01 mg or better, and raises a liquid vessel until contact is made. For a plate or single fiber of known perimeter, the force change on immersion and withdrawal gives advancing and receding angles through the Wilhelmy equation. For powders and porous solids, liquid uptake into a packed column is recorded as mass squared versus time, and the Washburn equation yields the contact angle when a reference fully wetting liquid has been used to determine the capillary constant. The instrument also measures liquid surface tension with a ring or plate. Stage speed is typically 0.1 to 500 mm/min, with position resolution of 0.1 µm. Clean glassware and a vibration-free bench are essential.
The contact angle is defined by Young's equation, which balances the solid–vapor, solid–liquid and liquid–vapor interfacial tensions at the three-phase line. An optical contact angle meter places a drop of a few microliters on the sample, images its silhouette with a camera under backlight, and fits the drop profile using a tangent, circle or Young–Laplace model to compute the angle. Advancing and receding angles are measured by adding and removing liquid or by tilting the stage, and their difference is the hysteresis. Using several test liquids, surface free energy is calculated by the Owens–Wendt or Wu methods. Force tensiometers infer the angle from the wetting force on a Wilhelmy plate, fiber or powder column.
A typical force tensiometer for dynamic wetting of fibers and powders configuration offers balance resolution of 0.01 mg, balance capacity of 210 g, stage speed of 0.1–500 mm/min, position resolution of 0.1 µm, surface tension range of 1–2000 mN/m and surface tension accuracy of ±0.1 mN/m. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Force Tensiometer for Dynamic Wetting of Fibers and Powders is used in single-fiber wetting of composites, powder wettability and dispersibility, textile and filter medium wetting and surfactant solution characterization. Across the wider Contact Angle Meters class, laboratories also deploy it for coating and paint wetting, plasma and corona treatment verification and adhesion promotion on plastics.
Relevant standards and methods include ASTM D7334, ASTM D5946, ISO 19403-2, ASTM D724 and DIN 55660-2. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Contact angles are sensitive to contamination, so handle samples with clean tweezers, avoid touching test areas and record storage and cleaning procedures. Use ultrapure water or high-purity test liquids and replace syringes and needles regularly. Place the instrument on a vibration-free bench with stable lighting, and level the stage. Verify the optical system with a calibration sphere or a reference surface of known angle. Control temperature and humidity, because drops evaporate, and measure within defined times after deposition. Report the number of drops, drop volume, liquid and fitting method along with the mean and standard deviation.
Select this variant for fibers, powders, porous media and uniform plates where sessile-drop imaging fails or where dynamic immersion data are required. It is less convenient for routine flat-film checks. In an RFQ, specify balance resolution, accessories, temperature control, and methods to be used.
Match the instrument to the sample and to the required data. Flat films, coatings and wafers suit a benchtop optical goniometer with a motorized syringe. Large or curved parts, such as automotive panels, may need a portable or large-stage system. Dynamic measurements, including advancing and receding angles or tilting stage tests, need automated dosing and a high-speed camera. Fibers, powders and porous solids are better measured with a force tensiometer. Consider camera resolution and frame rate, stage travel, temperature and humidity control, dosing accuracy, software models and compliance with ASTM D7334, ASTM D5946 or ISO 19403. For production lines, a quick single-point portable tester is often enough.
| Balance resolution | 0.01 mg |
|---|---|
| Balance capacity | 210 g |
| Stage speed | 0.1–500 mm/min |
| Position resolution | 0.1 µm |
| Surface tension range | 1–2000 mN/m |
| Surface tension accuracy | ±0.1 mN/m |
| Temperature control | 10–90 °C, ±0.1 °C |
| Fiber diameter range | 5–500 µm |
| Methods | Wilhelmy, Washburn, du Noüy ring |
| Sample vessel volume | 10–100 mL |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
A tensiometer is preferred for fibers, powders and uniform plates where the drop cannot be imaged, and when an average angle over the full perimeter is wanted rather than one local value from a drop.
It measures how fast a liquid wicks into a packed powder column by recording mass gain over time. Squared mass versus time is linear, and the slope, with a capillary constant from a fully wetting liquid, gives contact angle.
Yes. With a Wilhelmy plate or du Noüy ring attached to the balance, it measures liquid surface and interfacial tension, making it a dual-purpose instrument for formulation and wetting studies.
It indicates how well a liquid wets a surface. Angles below 90° show wetting, above 90° show poor wetting, and above 150° indicate superhydrophobic behavior. Combined with several liquids, it yields surface free energy for adhesion and coating decisions.
It is the difference between advancing and receding contact angles measured as the liquid front moves across a surface. Large hysteresis indicates roughness or chemical heterogeneity and explains why drops stick to inclined surfaces.
At least three to five drops at different locations per sample are commonly reported, with mean and standard deviation. Heterogeneous or rough surfaces may require ten or more drops, because local variation is large.