Benchtop Optical Contact Angle Goniometer with Motorized Dosing
带电动加液的台式光学接触角测角仪
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

带倾斜台的动态接触角测角仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Tilt range | 0–90° |
|---|---|
| Tilt resolution | 0.1° |
| Camera speed | up to 500 fps |
| Contact angle range | 0–180° |
| Angle accuracy | ±0.5° |
| Drop volume | 1–100 µL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D7334, ASTM D5946, ISO 19403-2
A goniometer with a motorized tilting base and high-speed camera that measures advancing, receding and sliding angles as a drop rolls on an inclined surface. It is the right choice for self-cleaning, anti-icing and hydrophobic coating evaluation.
A goniometer with a motorized tilting base and high-speed camera that measures advancing, receding and sliding angles as a drop rolls on an inclined surface. It is the right choice for self-cleaning, anti-icing and hydrophobic coating evaluation.
This variant adds a motorized tilting stage, typically 0° to 90° in steps of 0.1°, and a camera running at 100 to 500 frames per second. A drop of fixed volume, commonly 10 to 50 µL, is deposited and the stage tilts until the drop starts to roll; the angles at the front and rear of the moving drop give advancing and receding values, and the tilt angle at motion gives the sliding angle. Hysteresis is calculated as the difference. The same hardware supports needle-in and needle-out methods by adding and withdrawing liquid. Software tracks contact line velocity and reports angle versus time. This is the preferred way to characterize superhydrophobic or water-repellent materials because static angle alone cannot distinguish sticky from slippery surfaces.
The contact angle is defined by Young's equation, which balances the solid–vapor, solid–liquid and liquid–vapor interfacial tensions at the three-phase line. An optical contact angle meter places a drop of a few microliters on the sample, images its silhouette with a camera under backlight, and fits the drop profile using a tangent, circle or Young–Laplace model to compute the angle. Advancing and receding angles are measured by adding and removing liquid or by tilting the stage, and their difference is the hysteresis. Using several test liquids, surface free energy is calculated by the Owens–Wendt or Wu methods. Force tensiometers infer the angle from the wetting force on a Wilhelmy plate, fiber or powder column.
A typical dynamic contact angle goniometer with tilting stage configuration offers tilt range of 0–90°, tilt resolution of 0.1°, camera speed of up to 500 fps, contact angle range of 0–180°, angle accuracy of ±0.5° and drop volume of 1–100 µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Dynamic Contact Angle Goniometer with Tilting Stage is used in superhydrophobic coating development, anti-icing and self-cleaning surfaces, textile and membrane water repellency and hysteresis studies on rough surfaces. Across the wider Contact Angle Meters class, laboratories also deploy it for coating and paint wetting, plasma and corona treatment verification and adhesion promotion on plastics.
Relevant standards and methods include ASTM D7334, ASTM D5946, ISO 19403-2, ASTM D724 and DIN 55660-2. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Contact angles are sensitive to contamination, so handle samples with clean tweezers, avoid touching test areas and record storage and cleaning procedures. Use ultrapure water or high-purity test liquids and replace syringes and needles regularly. Place the instrument on a vibration-free bench with stable lighting, and level the stage. Verify the optical system with a calibration sphere or a reference surface of known angle. Control temperature and humidity, because drops evaporate, and measure within defined times after deposition. Report the number of drops, drop volume, liquid and fitting method along with the mean and standard deviation.
Select this variant when dynamic behavior matters, such as advancing/receding angles, roll-off or self-cleaning. Static work alone does not justify the added cost. In an RFQ, specify camera frame rate, tilt range, drop volume, environmental control and export of video and angle-versus-time data.
Match the instrument to the sample and to the required data. Flat films, coatings and wafers suit a benchtop optical goniometer with a motorized syringe. Large or curved parts, such as automotive panels, may need a portable or large-stage system. Dynamic measurements, including advancing and receding angles or tilting stage tests, need automated dosing and a high-speed camera. Fibers, powders and porous solids are better measured with a force tensiometer. Consider camera resolution and frame rate, stage travel, temperature and humidity control, dosing accuracy, software models and compliance with ASTM D7334, ASTM D5946 or ISO 19403. For production lines, a quick single-point portable tester is often enough.
| Tilt range | 0–90° |
|---|---|
| Tilt resolution | 0.1° |
| Camera speed | up to 500 fps |
| Contact angle range | 0–180° |
| Angle accuracy | ±0.5° |
| Drop volume | 1–100 µL |
| Tilting speed | 0.1–5°/s |
| Sample size | Up to 100 × 100 mm |
| Dosing | Motorized syringe |
| Measurements | Advancing, receding, sliding angle |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
The sliding angle is the tilt angle of the surface at which a drop of a given volume begins to move. Low sliding angles, for example below 10°, indicate easy roll-off, which is valued in self-cleaning and anti-icing coatings.
The tilting method uses gravity on a drop of fixed volume and gives advancing and receding angles at the moment of sliding. The needle method adds or removes liquid while the drop stays in place, and results may differ.
Drops can slide or roll within a fraction of a second on hydrophobic surfaces. A camera at 100 fps or higher captures the motion so software can find contact line positions and angles at the onset of movement.
It indicates how well a liquid wets a surface. Angles below 90° show wetting, above 90° show poor wetting, and above 150° indicate superhydrophobic behavior. Combined with several liquids, it yields surface free energy for adhesion and coating decisions.
It is the difference between advancing and receding contact angles measured as the liquid front moves across a surface. Large hysteresis indicates roughness or chemical heterogeneity and explains why drops stick to inclined surfaces.
At least three to five drops at different locations per sample are commonly reported, with mean and standard deviation. Heterogeneous or rough surfaces may require ten or more drops, because local variation is large.