Skip to main content
Lab Manufacturers China
Burner Heads and Nebulizers for Atomic Absorption — product photo

Burner Heads and Nebulizers for Atomic Absorption

原子吸收燃烧头和雾化器

  • SKU AAA-0006
  • AAS Accessories
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 safety compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Nebulizer typeconcentric, V-groove or inert
Sample uptake rate4–6 mL/min
Burner slot length50–100 mm
Burner materialstitanium, stainless, inert polymer
Flame typesair-acetylene, N2O-acetylene
Aerosol droplet sizemostly below 10 µm
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification

What is the Burner Heads and Nebulizers for Atomic Absorption?

Burner heads and nebulizers are the flame atomizer components that create and stabilize the aerosol and flame. They are key replacement parts for flame atomic absorption sensitivity, noise and safety, and worn parts cause drift.

What is the Burner Heads and Nebulizers for Atomic Absorption?

Burner heads and nebulizers are the flame atomizer components that create and stabilize the aerosol and flame. They are key replacement parts for flame atomic absorption sensitivity, noise and safety, and worn parts cause drift.

Overview

The nebulizer converts the liquid sample into a fine aerosol, and the spray chamber removes large droplets before the aerosol reaches the burner head, where it burns in the fuel-oxidant flame. Nebulizer design, uptake rate and droplet size distribution determine how much sample reaches the flame and thus sensitivity. Burner heads are supplied with different slot lengths and materials for air-acetylene or nitrous oxide-acetylene flames, and some are made of titanium or inert polymers for corrosive samples or hydrofluoric acid. Slot clogging from salts or corrosion causes noise, drift and poor precision and is a common maintenance issue. Gas flow control interacts with burner design, and safety interlocks detect incorrect head installation. Selecting the correct combination for the matrix and element, and keeping spares, protects both data quality and laboratory safety.

How does it work?

Accessories determine the practical performance of an atomic absorption instrument. Light sources must emit the correct resonance line with sufficient intensity and stability; hollow-cathode and electrodeless discharge lamps are selected by element and current range. Atomizers convert the sample into free atoms, and their condition strongly affects sensitivity and precision. Graphite tubes and platforms are consumables whose coating, geometry and number of firings set detection limits and tube life. Burner heads and nebulizers control aerosol formation and flame stability, and worn components cause noise, drift and poor recovery. Autosamplers provide reproducible sample and modifier delivery, and hydride manifolds add volatile-element capability. Choosing the right accessory for the element, matrix and instrument model, and replacing consumables on schedule, is essential for valid results.

What are the key features?

  • Nebulizer with controlled uptake and droplet size
  • Spray chamber to remove large droplets
  • Burner heads for air-acetylene or N2O-acetylene
  • Titanium and inert polymer options for corrosive samples
  • Safety interlocks for correct head installation
  • Replacement parts to restore sensitivity and stability

What are the technical specifications?

A typical burner heads and nebulizers for atomic absorption configuration offers nebulizer type of concentric, V-groove or inert, sample uptake rate of 4–6 mL/min, burner slot length of 50–100 mm, burner materials of titanium, stainless, inert polymer, flame types of air-acetylene, N2O-acetylene and aerosol droplet size of mostly below 10 µm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Burner Heads and Nebulizers for Atomic Absorption is used in restoring flame AAS sensitivity after wear, high dissolved-solids and brine samples, corrosive and hydrofluoric acid digests and routine prevention of burner clogging. Across the wider AAS Accessories class, laboratories also deploy it for replacement lamps for element-specific analysis, atomizer consumables for trace-metal programs and automation upgrades for high-throughput laboratories.

Which standards and certifications apply?

Relevant standards and methods include Ph. Eur. 2.2.22 Atomic absorption spectrometry, USP <852> Atomic Absorption Spectroscopy, USP <1058> Analytical Instrument Qualification, ISO/IEC 17025 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 safety compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Consumables degrade with use, and their condition affects accuracy more than many operators expect. Hollow-cathode lamps lose intensity and drift as they age; record lamp hours and replace before performance falls. Graphite tubes develop cracks, change sensitivity and eventually fail; monitor firings and apparent sensitivity. Burner slots clog with salt deposits that cause noise, and nebulizers block or corrode, so clean them regularly. Autosampler tubing stretches and changes volume, requiring scheduled replacement. Keep spare critical parts, especially for high-throughput laboratories, and store lamps and tubes in dry conditions. When replacing parts, verify performance with standards and record the change in the instrument log.

How do I select the right Burner Heads and Nebulizers for Atomic Absorption?

Select burner heads and nebulizers to match the flame type, sample corrosivity and dissolved-solids level, and confirm the part numbers for your instrument. Use inert nebulizers and polymer or titanium heads for corrosive or high-salt matrices. Keep a spare head and nebulizer on hand and clean them after high-salt runs to preserve sensitivity and safety.

How does it compare with other AAS Accessories variants?

Select accessories by matching them exactly to the instrument model, the element and the matrix. Lamps must be specified for the correct element and compatible socket, and the current range should suit the instrument. Graphite tubes should match the furnace geometry, whether transverse or end heated, and the coating must suit the elements measured, since carbide-forming elements need pyrolytically coated or special tubes. Burner heads and nebulizers must be chosen for the gas mixture and dissolved-solids level. Autosampler capacity and vial type depend on throughput and sample volume. Hydride manifolds must be compatible with the existing gas-liquid separator and quartz cell. Confirm part numbers, expected life and availability of certified performance data before ordering.

Full specifications

Full specifications
Nebulizer typeconcentric, V-groove or inert
Sample uptake rate4–6 mL/min
Burner slot length50–100 mm
Burner materialstitanium, stainless, inert polymer
Flame typesair-acetylene, N2O-acetylene
Aerosol droplet sizemostly below 10 µm
Spray chamber volume50–200 mL
Compatible instrumentsmodel specific
Cleaning requirementafter high-salt runs
Safety interlockhead recognition

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Restoring flame AAS sensitivity after wear
  • High dissolved-solids and brine samples
  • Corrosive and hydrofluoric acid digests
  • Routine prevention of burner clogging

Key features

  • Nebulizer with controlled uptake and droplet size
  • Spray chamber to remove large droplets
  • Burner heads for air-acetylene or N2O-acetylene
  • Titanium and inert polymer options for corrosive samples
  • Safety interlocks for correct head installation
  • Replacement parts to restore sensitivity and stability

Frequently asked questions about Burner Heads and Nebulizers for Atomic Absorption

Sensitivity falls, noise rises or the uptake rate drops and cannot be restored by cleaning. A blocked or corroded capillary, or a cracked inert nebulizer, requires replacement. Measure uptake rate with water and compare against the specification as a simple health check.

Related models

All AAS Accessories

Request a quotation for the Burner Heads and Nebulizers for Atomic Absorption

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote