Cytology Stainers

细胞学染色机

CST · Cytology Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1

Standards referenced

  • IEC 61010-1
  • IEC 61010-2-101
  • IEC 61326-1
  • ISO 15189

What are Cytology Stainers?

Cytology stainers apply Papanicolaou, Giemsa or other differential stains to cell preparations so nuclear and cytoplasmic detail can be assessed. Cytology screening and diagnostic laboratories use them to obtain reproducible colour and contrast across large numbers of monolayer slides.

5 models of Cytology Stainers

The 5 models below are current configurations; specifications are confirmed on quotation.

Manual Cytology Staining Station

手工细胞学染色工作站

  • CST-0001
  • Cytology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Staining bath count:
10–20 baths
Bath volume:
about 200–300 mL
Slide capacity per rack:
20–30 slides
Rinse station:
Running water or buffer
Exhaust airflow:
about 0.3–0.5 m/s face velocity
Bench material:
Solvent-resistant phenolic resin

A manual cytology staining station groups staining baths, rinse stations and a fume enclosure for operator-controlled staining. It suits low-volume cytology work, teaching and research protocols that need careful visual judgement of colour development.

Request a quote
View details

Automated Papanicolaou Slide Stainer

自动巴氏染色机

  • CST-0002
  • Cytology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Throughput:
200–600 slides per hour
Slide capacity:
up to about 500 slides
Reagent stations:
20–30 stations
Cycle time:
about 30–60 min
Agitation:
Programmable rocking or vertical
Reagent monitoring:
Bath age and slide count

An automated Papanicolaou slide stainer runs the complete Pap sequence of hematoxylin, orange G and eosin-azure counterstaining. It is chosen for cervical screening programmes where hundreds of monolayer slides must stain identically.

Request a quote
View details

Automated May-Grünwald Giemsa Slide Stainer

自动迈-格-吉姆萨染色机

  • CST-0003
  • Cytology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Throughput:
100–400 slides per hour
Slide capacity:
about 20–60 slides
Stain steps:
May-Grünwald, buffer, Giemsa
Cycle time:
about 10–25 min
Buffer control:
pH monitored, buffered rinse
Temperature:
ambient to 37 °C

An automated May-Grünwald Giemsa stainer applies panoptic staining to air-dried cytology and haematology preparations. It is chosen where nuclear chromatin, cytoplasm and microorganisms must all be clearly shown in a single stain.

Request a quote
View details

Linear Cytology Slide Stainer

线性细胞学染色机

  • CST-0004
  • Cytology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Rack capacity on track:
5–10 racks
Slide throughput:
about 100–200 slides
Reagent stations:
12–24 stations
Bath volume:
about 250–500 mL
Dwell time range:
10 s to 10 min per station
Heating:
Selected stations to 40 °C

A linear cytology slide stainer moves racks along a track through fixed reagent baths at set intervals. It provides reproducible staining at moderate throughput with simple mechanics and low purchase and running cost.

Request a quote
View details

Benchtop Cytology Slide Stainer

台式细胞学染色机

  • CST-0005
  • Cytology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
Slide capacity:
20–60 slides per run
Rack capacity:
1–3 racks
Reagent stations:
10–16 stations
Bath volume:
about 100–200 mL
Cycle time:
about 20–45 min
Heating:
Optional to 40 °C

A benchtop cytology slide stainer brings automated staining to small laboratories with limited bench space, workload and budget. It typically stains 20 to 60 slides per run using simple, reproducible programmable protocols and small reagent volumes.

Request a quote
View details

Compare Cytology Stainers models

ModelBath volumePower supplyThroughputSlide capacityReagent stations
Manual Cytology Staining StationCST-0001about 200–300 mL220 V, 50 Hz———
Automated Papanicolaou Slide StainerCST-0002—220 V, 50 Hz, about 1–2 kW200–600 slides per hourup to about 500 slides20–30 stations
Automated May-Grünwald Giemsa Slide StainerCST-0003—220 V, 50 Hz, about 0.5 kW100–400 slides per hourabout 20–60 slides—
Linear Cytology Slide StainerCST-0004about 250–500 mL220 V, 50 Hz, about 0.5 kW——12–24 stations
Benchtop Cytology Slide StainerCST-0005about 100–200 mL220 V, 50 Hz, about 0.3 kW—20–60 slides per run10–16 stations

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Cytology Stainers work?

Cytology staining differentiates cellular structures by exploiting their affinity for dyes. In the Papanicolaou method, hematoxylin stains nuclei blue, while orange G and eosin-azure counterstains give keratinised and metabolically active cells their characteristic orange, pink and blue-green shades. Giemsa-type stains give a panoptic result that shows nuclear chromatin, cytoplasm and microorganisms, and is common for air-dried samples. A stainer moves slide racks or individual slides through alcohol, dye, rinse and clearing stations for controlled times, often with agitation, and may dry them before coverslipping. Alcohol concentrations, dye pH, dwell time and rinse efficiency determine the final balance of colours, so reagent quality and stable timing are the critical variables.

Which Cytology Stainers variants are available?

  • Manual Cytology Staining Station — A manual cytology staining station groups staining baths, rinse stations and a fume enclosure for operator-controlled staining.
  • Automated Papanicolaou Slide Stainer — An automated Papanicolaou slide stainer runs the complete Pap sequence of hematoxylin, orange G and eosin-azure counterstaining.
  • Automated May-Grünwald Giemsa Slide Stainer — An automated May-Grünwald Giemsa stainer applies panoptic staining to air-dried cytology and haematology preparations.
  • Linear Cytology Slide Stainer — A linear cytology slide stainer moves racks along a track through fixed reagent baths at set intervals.
  • Benchtop Cytology Slide Stainer — A benchtop cytology slide stainer brings automated staining to small laboratories with limited bench space, workload and budget.

How do I choose the right variant?

Choose a cytology stainer by slide volume, stain menu and workflow. Manual staining stations suit low volumes and teaching, and give full control when colours need adjustment. Automated Papanicolaou stainers are the standard for cervical screening, where hundreds of slides per day must look identical; Giemsa stainers suit haematology and air-dried cytology. Linear stainers offer moderate throughput with simple mechanics, while benchtop units fit small laboratories. Compare slides per run, station count and volume, programmability, agitation, wash efficiency, drying and coverslipping integration. Check carryover prevention, reagent consumption and whether the instrument accepts third-party reagents or requires proprietary kits.

Where are Cytology Stainers used?

Cytology Stainers are specified in cervical cytology screening, papanicolaou staining, giemsa staining of air-dried samples, body fluid cytology, fine-needle aspirate cytology and veterinary cytology.

Which standards and certifications apply?

Work with Cytology Stainers is commonly governed by IEC 61010-1, IEC 61010-2-101, IEC 61326-1 and ISO 15189. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Install the stainer near water and drainage if rinsing requires running water, and keep it away from direct light that fades dyes. Prepare fresh hematoxylin and counterstains on a defined schedule based on slide counts, and monitor with control slides, because colour drift is usually chemical rather than mechanical. Clean baths, nozzles and tubing to prevent precipitate and microbial growth, and check that filtering steps remove dye particles. Record reagent lots, changes and quality control results. Train staff in safe handling of dyes and alcohols, and ensure adequate ventilation for any solvent-based clearing step.

Frequently asked questions about Cytology Stainers

It applies differential stains such as Papanicolaou or Giemsa to cell preparations, giving reproducible colour that shows nuclear and cytoplasmic detail. It replaces manual dipping so large numbers of slides stain consistently in screening and diagnostic laboratories.