Benchtop Cytology Slide Stainer
台式细胞学染色机
- SKU CST-0005
- Cytology Stainers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Slide capacity | 20–60 slides per run |
|---|---|
| Rack capacity | 1–3 racks |
| Reagent stations | 10–16 stations |
| Bath volume | about 100–200 mL |
| Cycle time | about 20–45 min |
| Heating | Optional to 40 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1
What is the Benchtop Cytology Slide Stainer?
A benchtop cytology slide stainer brings automated staining to small laboratories with limited bench space, workload and budget. It typically stains 20 to 60 slides per run using simple, reproducible programmable protocols and small reagent volumes.
What is the Benchtop Cytology Slide Stainer?
A benchtop cytology slide stainer brings automated staining to small laboratories with limited bench space, workload and budget. It typically stains 20 to 60 slides per run using simple, reproducible programmable protocols and small reagent volumes.
Overview
The benchtop cytology stainer is scaled for laboratories that cannot justify a large platform but still want consistent staining. It usually holds one to three slide racks and runs programs for Papanicolaou, Giemsa or a limited set of other stains, with programmable dwell times and sometimes heated stations. Reagent volumes are small, which lowers reagent cost but shortens replacement intervals and makes quality control more demanding. These instruments generally do not include coverslipping, so slides are dried and mounted separately, either by hand or with a standalone coverslipper. They are common in small hospitals, veterinary practices, teaching laboratories and research groups, where simple operation, modest cost and a small footprint matter more than maximum throughput. Check whether programs can be edited for local protocols.
How does it work?
Cytology staining differentiates cellular structures by exploiting their affinity for dyes. In the Papanicolaou method, hematoxylin stains nuclei blue, while orange G and eosin-azure counterstains give keratinised and metabolically active cells their characteristic orange, pink and blue-green shades. Giemsa-type stains give a panoptic result that shows nuclear chromatin, cytoplasm and microorganisms, and is common for air-dried samples. A stainer moves slide racks or individual slides through alcohol, dye, rinse and clearing stations for controlled times, often with agitation, and may dry them before coverslipping. Alcohol concentrations, dye pH, dwell time and rinse efficiency determine the final balance of colours, so reagent quality and stable timing are the critical variables.
What are the key features?
- Automated staining in a small bench footprint
- Capacity of about 20–60 slides per run
- Programmable dwell time and optional heating
- Programs for Pap, Giemsa and selected stains
- Small reagent volumes lower reagent cost
- Simple operation for small laboratories
What are the technical specifications?
A typical benchtop cytology slide stainer configuration offers slide capacity of 20–60 slides per run, rack capacity of 1–3 racks, reagent stations of 10–16 stations, bath volume of about 100–200 mL, cycle time of about 20–45 min and heating of Optional to 40 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Cytology Slide Stainer is used in small hospital laboratories, veterinary cytology, teaching and training and research groups. Across the wider Cytology Stainers class, laboratories also deploy it for cervical cytology screening, papanicolaou staining and giemsa staining of air-dried samples.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1 and ISO 15189. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the stainer near water and drainage if rinsing requires running water, and keep it away from direct light that fades dyes. Prepare fresh hematoxylin and counterstains on a defined schedule based on slide counts, and monitor with control slides, because colour drift is usually chemical rather than mechanical. Clean baths, nozzles and tubing to prevent precipitate and microbial growth, and check that filtering steps remove dye particles. Record reagent lots, changes and quality control results. Train staff in safe handling of dyes and alcohols, and ensure adequate ventilation for any solvent-based clearing step.
How do I select the right Benchtop Cytology Slide Stainer?
Choose a benchtop stainer when space is limited and daily volume is below about 60 slides, but consistent timing still matters. Confirm slide capacity, programmability, heating and whether coverslipping is separate. Include the cost of frequent reagent changes in the comparison.
How does it compare with other Cytology Stainers variants?
Choose a cytology stainer by slide volume, stain menu and workflow. Manual staining stations suit low volumes and teaching, and give full control when colours need adjustment. Automated Papanicolaou stainers are the standard for cervical screening, where hundreds of slides per day must look identical; Giemsa stainers suit haematology and air-dried cytology. Linear stainers offer moderate throughput with simple mechanics, while benchtop units fit small laboratories. Compare slides per run, station count and volume, programmability, agitation, wash efficiency, drying and coverslipping integration. Check carryover prevention, reagent consumption and whether the instrument accepts third-party reagents or requires proprietary kits.
Full specifications
| Slide capacity | 20–60 slides per run |
|---|---|
| Rack capacity | 1–3 racks |
| Reagent stations | 10–16 stations |
| Bath volume | about 100–200 mL |
| Cycle time | about 20–45 min |
| Heating | Optional to 40 °C |
| Footprint | about 500 × 400 mm |
| Coverslipping | Separate instrument required |
| Power supply | 220 V, 50 Hz, about 0.3 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Small hospital laboratories
- Veterinary cytology
- Teaching and training
- Research groups
Key features
- Automated staining in a small bench footprint
- Capacity of about 20–60 slides per run
- Programmable dwell time and optional heating
- Programs for Pap, Giemsa and selected stains
- Small reagent volumes lower reagent cost
- Simple operation for small laboratories
Frequently asked questions about Benchtop Cytology Slide Stainer
Typically 20 to 60 slides depending on whether it holds one, two or three racks. If peak demand is higher, run several batches or choose a linear or larger automated stainer.
Most benchtop models allow dwell times to be edited and stored, so local protocols can be accommodated within the station count. Very unusual protocols may exceed the available stations or temperature range.
Bath volumes are small, so the same number of slides consumes a larger fraction of each dye. Follow the recommended slide counts and monitor with control slides, because weak or shifted colour usually indicates exhausted reagents.
It applies differential stains such as Papanicolaou or Giemsa to cell preparations, giving reproducible colour that shows nuclear and cytoplasmic detail. It replaces manual dipping so large numbers of slides stain consistently in screening and diagnostic laboratories.
Papanicolaou staining uses hematoxylin with orange G and eosin-azure counterstains and is designed for alcohol-fixed smears, giving clear nuclear detail and keratin colours. Giemsa staining is a panoptic stain suited to air-dried samples and is common in haematology.
Control reagent quality and timing. Prepare fresh dyes on a schedule based on slide counts, check pH and alcohol concentration, filter to remove precipitate, and run control slides each batch. Most colour drift is caused by exhausted reagents rather than the instrument.