What are Sample Preparation?

Sample preparation equipment for drug testing extracts, cleans and concentrates drugs and metabolites from urine, blood, oral fluid and hair before instrumental analysis. It includes SPE systems, evaporators, pulverizers and liquid handlers used by toxicology, forensic and workplace testing laboratories.

5 models of Sample Preparation

The 5 models below are current configurations; specifications are confirmed on quotation.

Positive-Pressure SPE Manifold for Drug Extraction

药物萃取用正压固相萃取装置

  • SAE-0001
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Format:
Cartridge (1–6 mL) and 96-well plate
Pressure range:
1–100 psi
Positions:
12, 24 or 96
Gas:
Nitrogen or clean air
Pressure control:
Digital regulator
Collection format:
Tubes or 96-well plate

A positive-pressure SPE manifold pushes samples and solvents through SPE cartridges or 96-well plates with controlled gas pressure. It gives consistent flow for urine and blood extraction in toxicology laboratories without a full robotic system.

Request a quote
View details

Automated SPE Workstation for Toxicology

毒理学用自动固相萃取工作站

  • SAE-0002
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Sample capacity:
Up to 96–384 per run
Pipetting volume range:
5–1000 µL
Pipetting accuracy:
≤ 2 % at 100 µL
Precision (CV):
≤ 1.5 %
SPE format:
96-well plate / cartridge
Processing time:
30–60 min per plate

An automated SPE workstation performs sample loading, washing, drying and elution on cartridges or 96-well plates without operator intervention. It is used by laboratories that extract hundreds of toxicology samples per day.

Request a quote
View details

Nitrogen Evaporator for Toxicology Extract Concentration

毒理提取物浓缩用氮吹仪

  • SAE-0003
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Positions:
12, 24, 48 or 96
Temperature range:
Ambient to 100 °C
Temperature accuracy:
± 1 °C
Gas:
Nitrogen, 0.5–5 bar
Needle adjustment:
Manual or automatic height
Tube size:
10–16 mm (or plate)

A nitrogen evaporator concentrates SPE eluates and liquid extracts by blowing heated nitrogen over the sample surface. It is used to dry down extracts and reconstitute them in a small volume before GC-MS or LC-MS/MS analysis.

Request a quote
View details

Cryogenic Hair Pulverizer for Drug Testing

毛发药物检测用低温粉碎机

  • SAE-0004
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Sample capacity:
10–50 mg hair per vial
Vials per run:
2–24
Shaking frequency:
3–30 Hz
Grinding time:
10 s–99 min
Cooling:
Liquid nitrogen (cryogenic version)
Vial material:
Stainless steel or PTFE

A cryogenic hair pulverizer grinds hair samples to a fine powder in sealed vials using steel balls, often chilled with liquid nitrogen. It gives repeatable extraction of incorporated drugs for hair drug testing.

Request a quote
View details

Automated Liquid Handling Workstation for Toxicology Sample Preparation

毒理样品前处理用自动液体处理工作站

  • SAE-0005
  • Sample Preparation
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Pipetting channels:
1–8 or 96-channel head
Volume range:
1–1000 µL
Accuracy:
≤ 2 % at 10 µL
Precision (CV):
≤ 2 %
Deck positions:
≥ 20
Tips:
Disposable, filtered

An automated liquid handling workstation prepares calibrators, controls and samples for toxicology by pipetting, diluting, adding internal standards and reformatting into plates. It improves precision and traceability in routine drug testing workflows.

Request a quote
View details

Compare Sample Preparation models

ModelPositionsGasPower supplySample capacityPrecision (CV)
Positive-Pressure SPE Manifold for Drug ExtractionSAE-000112, 24 or 96Nitrogen or clean air24 V DC / 220 V AC——
Automated SPE Workstation for ToxicologySAE-0002——220 V, 50/60 HzUp to 96–384 per run≤ 1.5 %
Nitrogen Evaporator for Toxicology Extract ConcentrationSAE-000312, 24, 48 or 96Nitrogen, 0.5–5 bar220 V, 50/60 Hz——
Cryogenic Hair Pulverizer for Drug TestingSAE-0004——220 V, 50/60 Hz10–50 mg hair per vial—
Automated Liquid Handling Workstation for Toxicology Sample PreparationSAE-0005——220 V, 50/60 Hz—≤ 2 %

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Sample Preparation work?

Biological samples contain proteins, lipids and salts that interfere with chromatography and mass spectrometry, so drugs must be separated before analysis. Solid-phase extraction passes the sample through a sorbent bed that retains the drug, is washed to remove interferences and releases the drug with an elution solvent. Supported liquid extraction uses a diatomaceous earth support to perform liquid-liquid extraction without emulsions. Hydrolysis with acid, base or enzyme such as beta-glucuronidase releases conjugated drugs. Evaporation with heated nitrogen concentrates extracts, and derivatization may be needed for GC-MS. Hair is decontaminated, pulverized or cut and extracted to release incorporated drug. Automated liquid handlers pipette samples, internal standards and reagents with volume precision near 1 percent. Good preparation improves recovery, reproducibility and instrument uptime.

Which Sample Preparation variants are available?

  • Positive-Pressure SPE Manifold for Drug Extraction — A positive-pressure SPE manifold pushes samples and solvents through SPE cartridges or 96-well plates with controlled gas pressure.
  • Automated SPE Workstation for Toxicology — An automated SPE workstation performs sample loading, washing, drying and elution on cartridges or 96-well plates without operator intervention.
  • Nitrogen Evaporator for Toxicology Extract Concentration — A nitrogen evaporator concentrates SPE eluates and liquid extracts by blowing heated nitrogen over the sample surface.
  • Cryogenic Hair Pulverizer for Drug Testing — A cryogenic hair pulverizer grinds hair samples to a fine powder in sealed vials using steel balls, often chilled with liquid nitrogen.
  • Automated Liquid Handling Workstation for Toxicology Sample Preparation — An automated liquid handling workstation prepares calibrators, controls and samples for toxicology by pipetting, diluting, adding internal standards and reformatting into plates.

How do I choose the right variant?

Choose according to sample type, volume and downstream technique. Positive-pressure manifolds suit laboratories running tens of SPE samples with consistent flow, while automated SPE workstations suit hundreds of samples and reduce hands-on time. Nitrogen evaporators are needed whenever eluates must be concentrated or solvents exchanged, and their throughput is set by the number of positions and block temperature range. Hair testing requires a cryogenic or ball-mill pulverizer to achieve reproducible extraction. Liquid handlers add precision and traceability for calibrators, internal standards and dilutions. Check plate formats, such as 96-well, compatibility with consumables, carryover control, solvent resistance and the ability to log operations. Consider operator safety, because organic solvents and biological samples are present.

Where are Sample Preparation used?

Sample Preparation are specified in urine and blood extraction for toxicology, hair testing preparation, workplace drug testing confirmation, forensic casework extraction and oral fluid sample preparation.

Which standards and certifications apply?

Work with Sample Preparation is commonly governed by ANSI/ASB Standard 036, ISO/IEC 17025, ISO 15189, CLSI C62 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Validate each preparation method for recovery, matrix effects, precision and carryover, and use isotope-labeled internal standards added early. Keep consistent flow rates and drying times in SPE because variation changes recovery. Place evaporators and manifolds in a fume hood or use solvent vapor extraction, and follow biosafety procedures for blood and urine. Clean pipetting channels, needles and manifold ports regularly to avoid cross-contamination. Use calibrated pipettes and balances, verify temperature blocks with an independent thermometer, and document maintenance. For hair, decontamination steps must be defined and controlled. Keep chain-of-custody records and label every tube, plate and vial unambiguously.

Frequently asked questions about Sample Preparation

Biological samples contain proteins, salts and lipids that interfere with chromatography and mass spectrometry. Preparation removes these interferences, concentrates the drug and improves accuracy, sensitivity and instrument life.

Need help specifying Sample Preparation?

Request a quote