Cryogenic Hair Pulverizer for Drug Testing
毛发药物检测用低温粉碎机
- SKU SAE-0004
- Sample Preparation
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sample capacity | 10–50 mg hair per vial |
|---|---|
| Vials per run | 2–24 |
| Shaking frequency | 3–30 Hz |
| Grinding time | 10 s–99 min |
| Cooling | Liquid nitrogen (cryogenic version) |
| Vial material | Stainless steel or PTFE |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ANSI/ASB Standard 036, ISO/IEC 17025, ISO 15189
What is the Cryogenic Hair Pulverizer for Drug Testing?
A cryogenic hair pulverizer grinds hair samples to a fine powder in sealed vials using steel balls, often chilled with liquid nitrogen. It gives repeatable extraction of incorporated drugs for hair drug testing.
What is the Cryogenic Hair Pulverizer for Drug Testing?
A cryogenic hair pulverizer grinds hair samples to a fine powder in sealed vials using steel balls, often chilled with liquid nitrogen. It gives repeatable extraction of incorporated drugs for hair drug testing.
Overview
Hair is first washed to remove external contamination, then placed in a sealed stainless steel or polymer vial with one or more steel balls. The pulverizer shakes the vials at high frequency, typically 20 to 30 Hz, for one to five minutes, and the impact fractures the keratin matrix into a fine powder. Cryogenic versions pre-cool the vials to about minus 196 °C to embrittle the hair, which improves fineness and avoids heating. Powdering improves extraction efficiency and reproducibility compared with cutting because drug diffuses faster from smaller particles. Vials are available in sizes for 10 to 50 mg of hair. Throughput depends on the number of vials the machine can hold, from 2 to 24 per run. Vials and balls must be cleaned thoroughly to avoid cross-contamination between samples.
How does it work?
Biological samples contain proteins, lipids and salts that interfere with chromatography and mass spectrometry, so drugs must be separated before analysis. Solid-phase extraction passes the sample through a sorbent bed that retains the drug, is washed to remove interferences and releases the drug with an elution solvent. Supported liquid extraction uses a diatomaceous earth support to perform liquid-liquid extraction without emulsions. Hydrolysis with acid, base or enzyme such as beta-glucuronidase releases conjugated drugs. Evaporation with heated nitrogen concentrates extracts, and derivatization may be needed for GC-MS. Hair is decontaminated, pulverized or cut and extracted to release incorporated drug. Automated liquid handlers pipette samples, internal standards and reagents with volume precision near 1 percent. Good preparation improves recovery, reproducibility and instrument uptime.
What are the key features?
- High-frequency shaking at 20 to 30 Hz for fine powdering
- Cryogenic pre-cooling to embrittle hair and avoid heating
- Sealed vials that prevent loss and cross-contamination
- Programmable time and frequency for reproducible grinding
- Vial sets for 10 to 50 mg hair samples
What are the technical specifications?
A typical cryogenic hair pulverizer for drug testing configuration offers sample capacity of 10–50 mg hair per vial, vials per run of 2–24, shaking frequency of 3–30 Hz, grinding time of 10 s–99 min, cooling of Liquid nitrogen (cryogenic version) and vial material of Stainless steel or PTFE. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Cryogenic Hair Pulverizer for Drug Testing is used in hair drug testing, forensic hair analysis, doping control in hair and retrospective exposure studies. Across the wider Sample Preparation class, laboratories also deploy it for urine and blood extraction for toxicology, hair testing preparation and workplace drug testing confirmation.
Which standards and certifications apply?
Relevant standards and methods include ANSI/ASB Standard 036, ISO/IEC 17025, ISO 15189, CLSI C62 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Validate each preparation method for recovery, matrix effects, precision and carryover, and use isotope-labeled internal standards added early. Keep consistent flow rates and drying times in SPE because variation changes recovery. Place evaporators and manifolds in a fume hood or use solvent vapor extraction, and follow biosafety procedures for blood and urine. Clean pipetting channels, needles and manifold ports regularly to avoid cross-contamination. Use calibrated pipettes and balances, verify temperature blocks with an independent thermometer, and document maintenance. For hair, decontamination steps must be defined and controlled. Keep chain-of-custody records and label every tube, plate and vial unambiguously.
How do I select the right Cryogenic Hair Pulverizer for Drug Testing?
Select a pulverizer for routine hair testing where consistent extraction matters. Cutting with scissors is acceptable for screening, but pulverization improves recovery. In an RFQ, specify vials per run, frequency, cooling method, vial material and cleaning validation needs.
How does it compare with other Sample Preparation variants?
Choose according to sample type, volume and downstream technique. Positive-pressure manifolds suit laboratories running tens of SPE samples with consistent flow, while automated SPE workstations suit hundreds of samples and reduce hands-on time. Nitrogen evaporators are needed whenever eluates must be concentrated or solvents exchanged, and their throughput is set by the number of positions and block temperature range. Hair testing requires a cryogenic or ball-mill pulverizer to achieve reproducible extraction. Liquid handlers add precision and traceability for calibrators, internal standards and dilutions. Check plate formats, such as 96-well, compatibility with consumables, carryover control, solvent resistance and the ability to log operations. Consider operator safety, because organic solvents and biological samples are present.
Full specifications
| Sample capacity | 10–50 mg hair per vial |
|---|---|
| Vials per run | 2–24 |
| Shaking frequency | 3–30 Hz |
| Grinding time | 10 s–99 min |
| Cooling | Liquid nitrogen (cryogenic version) |
| Vial material | Stainless steel or PTFE |
| Ball material | Stainless steel, 5–10 mm |
| Final particle size | < 100 µm |
| Noise level | < 70 dB(A) |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Hair drug testing
- Forensic hair analysis
- Doping control in hair
- Retrospective exposure studies
Key features
- High-frequency shaking at 20 to 30 Hz for fine powdering
- Cryogenic pre-cooling to embrittle hair and avoid heating
- Sealed vials that prevent loss and cross-contamination
- Programmable time and frequency for reproducible grinding
- Vial sets for 10 to 50 mg hair samples
Frequently asked questions about Cryogenic Hair Pulverizer for Drug Testing
Pulverizing creates a fine powder with larger surface area, releasing drug into the extraction solvent more completely and reproducibly than cut segments, which improves recovery and sensitivity.
No. Some pulverizers work at room temperature and are adequate for many applications, but cryogenic grinding helps with thick or coarse hair and reduces heat exposure.
Vials and balls are washed with solvent and detergent, rinsed and dried, often with ultrasonic cleaning, and blank checks confirm no carryover before reuse.
Biological samples contain proteins, salts and lipids that interfere with chromatography and mass spectrometry. Preparation removes these interferences, concentrates the drug and improves accuracy, sensitivity and instrument life.
Solid-phase extraction passes the sample through a sorbent that retains the drug, washes away interferences and then elutes the drug in a small solvent volume. It gives cleaner extracts than simple protein precipitation.
Many drugs are excreted as glucuronide conjugates. Enzymatic or chemical hydrolysis releases the free drug so that total drug concentration can be measured accurately.