What are PCR Workstations?

PCR workstations are enclosed or hooded work areas for setting up PCR reactions with minimal contamination. They use HEPA-filtered airflow, UV decontamination or both to protect samples and reagents from airborne DNA, amplicons and particulates. Molecular diagnostic, forensic and research laboratories use them for pre-amplification set-up.

5 models of PCR Workstations

The 5 models below are current configurations; specifications are confirmed on quotation.

UV Dead-Air PCR Cabinet

紫外死空气 PCR 工作柜

  • PCW-0001
  • PCR Workstations
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Interior width:
600–900 mm
Work surface material:
304 stainless steel or acrylic
UV lamp:
254 nm, 15–30 W (1–2 lamps)
UV timer:
1–99 min, programmable
Airflow:
none (dead air)
HEPA filtration:
none

A UV dead-air PCR cabinet is an enclosed box with a front sash, a stainless or acrylic work surface and a germicidal UV lamp, with no airflow system. It is the right choice for low-cost reagent preparation and aliquoting where a still-air, decontaminated space is enough.

Request a quote
View details

Vertical Laminar-Flow PCR Hood with HEPA

垂直层流 HEPA PCR 超净罩

  • PCW-0002
  • PCR Workstations
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cleanliness class:
ISO 14644-1 Class 5
HEPA filter grade:
H14 (EN 1822)
Airflow direction:
Vertical downflow
Downflow velocity:
0.3–0.5 m/s
Interior width:
700–1200 mm
UV lamp:
254 nm, 30 W

A vertical laminar-flow PCR hood blows HEPA-filtered air downward over the work surface and adds a UV lamp, creating an ISO Class 5 environment for PCR set-up. It is the right choice for forensic, diagnostic and trace-DNA work where sample protection is the priority.

Request a quote
View details

Class II Type A2 PCR Safety Cabinet

Class II A2 型 PCR 生物安全柜

  • PCW-0003
  • PCR Workstations
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class II Type A2
Inflow velocity:
≥ 0.5 m/s
Downflow velocity:
0.25–0.50 m/s
HEPA filters:
H14 supply and exhaust (EN 1822)
Work width:
900–1800 mm
Sash opening height:
200–250 mm working

A Class II Type A2 PCR safety cabinet provides HEPA-filtered downflow for the sample and inward airflow for the operator, with a UV lamp, so infectious material can be prepared for PCR. It is the right choice for clinical and public-health laboratories handling specimens that must be contained.

Request a quote
View details

Automated PCR Setup Workstation

自动化 PCR 配制工作站

  • PCW-0004
  • PCR Workstations
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Plate formats:
96- and 384-well PCR plates
Pipetting volume range:
0.5–1000 µL
Pipetting accuracy:
±2% at 10 µL
Pipetting precision (CV):
< 2% at 10 µL
Set-up time, 96-well plate:
10–20 min
Enclosure airflow:
HEPA downflow, ISO Class 5

An automated PCR setup workstation uses a pipetting robot inside a HEPA- and UV-equipped enclosure to dispense master mix and template into PCR plates, typically 96 or 384 wells. It is the right choice for laboratories that need reproducible, traceable plate set-up at volumes above a few dozen reactions per day.

Request a quote
View details

Ductless Carbon-Filtered Post-PCR Workstation

无管道活性炭过滤 PCR 后工作站

  • PCW-0005
  • PCR Workstations
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Airflow direction:
Inward at front, filtered return to room
Face velocity:
0.4–0.5 m/s
HEPA filter grade:
H13 or H14 (EN 1822)
Carbon filter:
Activated carbon, organic vapor grade
Interior width:
600–1200 mm
Filter alarm:
Airflow and filter-life indicator

A ductless carbon-filtered post-PCR workstation is an exhaust enclosure that captures vapors and aerosols from post-amplification work, for example opening amplified tubes and loading gels, through HEPA and activated-carbon filters. It is the right choice for the post-PCR room when dyes or solvents are used and no exhaust duct is available.

Request a quote
View details

Compare PCR Workstations models

ModelInterior widthUV lampLightingNoise levelPower supply
UV Dead-Air PCR CabinetPCW-0001600–900 mm254 nm, 15–30 W (1–2 lamps)LED, about 400 lux< 40 dB(A)220 V AC, 50/60 Hz, about 80 W
Vertical Laminar-Flow PCR Hood with HEPAPCW-0002700–1200 mm254 nm, 30 WLED, ≥ 600 lux≤ 58 dB(A)220 V AC, 50/60 Hz, about 300 W
Class II Type A2 PCR Safety CabinetPCW-0003—254 nm, 30 WLED, ≥ 750 lux≤ 61 dB(A)220 V AC, 50/60 Hz, about 500 W
Automated PCR Setup WorkstationPCW-0004————100–240 V AC, 50/60 Hz, about 600 W
Ductless Carbon-Filtered Post-PCR WorkstationPCW-0005600–1200 mmOptional, 254 nm—≤ 58 dB(A)220 V AC, 50/60 Hz, about 300 W

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do PCR Workstations work?

PCR contamination arises mainly from amplicons carried over from previous reactions and from ambient DNA. A PCR workstation reduces this risk with three mechanisms. First, an enclosed or laminar-flow workspace limits airborne particles: HEPA filters remove at least 99.99% of particles at 0.3 µm, and airflow passes in a controlled direction over the work surface. Second, ultraviolet light at 254 nm crosslinks DNA on surfaces and in air inside the cabinet, destroying residual template. Third, smooth stainless steel or epoxy surfaces allow chemical cleaning with bleach or DNA-decontaminating reagents. Some systems add a door interlock so UV cannot run when the sash is open, and timers for automatic UV cycles.

Which PCR Workstations variants are available?

  • UV Dead-Air PCR Cabinet — A UV dead-air PCR cabinet is an enclosed box with a front sash, a stainless or acrylic work surface and a germicidal UV lamp, with no airflow system.
  • Vertical Laminar-Flow PCR Hood with HEPA — A vertical laminar-flow PCR hood blows HEPA-filtered air downward over the work surface and adds a UV lamp, creating an ISO Class 5 environment for PCR set-up.
  • Class II Type A2 PCR Safety Cabinet — A Class II Type A2 PCR safety cabinet provides HEPA-filtered downflow for the sample and inward airflow for the operator, with a UV lamp, so infectious material can be prepared for PCR.
  • Automated PCR Setup Workstation — An automated PCR setup workstation uses a pipetting robot inside a HEPA- and UV-equipped enclosure to dispense master mix and template into PCR plates, typically 96 or 384 wells.
  • Ductless Carbon-Filtered Post-PCR Workstation — A ductless carbon-filtered post-PCR workstation is an exhaust enclosure that captures vapors and aerosols from post-amplification work, for example opening amplified tubes and loading gels, through HEPA and activated-carbon filters.

How do I choose the right variant?

Select by the level of protection needed. A UV dead-air cabinet protects reagents at low cost, a laminar-flow hood adds HEPA airflow for cleaner preparation, and a Class II cabinet also protects the operator when handling infectious samples. Check interior size against the racks, pipettes and centrifuge you need inside, and confirm UV lamp wavelength, timer and door interlock. Ductless carbon-filter units suit post-PCR work with volatile reagents. Automated set-up stations reduce manual variability and suit high volumes. Consider noise, vibration and lighting, and whether the workstation must be certified to a biosafety standard such as EN 12469 or NSF/ANSI 49.

Where are PCR Workstations used?

PCR Workstations are specified in pre-PCR reagent and sample set-up, forensic DNA analysis, molecular diagnostics, pathogen screening and ancient and trace DNA work.

Which standards and certifications apply?

Work with PCR Workstations is commonly governed by EN 12469, NSF/ANSI 49, ISO 14644-1, EN 1822 (HEPA filters), IEC 61010-1, IEC 61010-2-101 and CLSI MM19. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Place the workstation in a low-traffic area of the pre-amplification room, away from doors and air vents. Clean surfaces before and after use with 10% bleach followed by water or 70% ethanol, and run the UV cycle, typically 15–30 minutes, before work. UV lamps lose output with age, so record hours and replace them at the manufacturer's interval, usually 6,000–9,000 hours. Test HEPA filter integrity and airflow velocity at installation and annually, or as required by the standard applied. Keep pipettes, tips and racks dedicated to the workstation, and never bring amplified product or post-PCR equipment into the pre-PCR area.

Frequently asked questions about PCR Workstations

A PCR workstation provides a clean, often UV-decontaminated space for preparing PCR reactions. It protects reagents and template from airborne DNA and amplicons, which reduces false-positive results in diagnostic, forensic and research amplification work.