Phase Analysis Light Scattering Zeta Potential Analyzer
相位分析光散射 Zeta 电位分析仪
- SKU ZPA-0002
- Zeta Potential Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Mobility range | ±20 µm·cm/V·s |
|---|---|
| Mobility sensitivity | ≤ 0.005 µm·cm/V·s |
| Zeta potential range | −500 to +500 mV |
| Measurement principle | PALS with field reversal |
| Laser | 633 nm or 660 nm, ≥ 10 mW |
| Applied field | Low-field, 5–20 V/cm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 13099-1, ISO 13099-2, ISO 13099-3
What is the Phase Analysis Light Scattering Zeta Potential Analyzer?
A zeta potential analyzer using phase analysis light scattering (PALS) to measure very small electrophoretic mobilities. It gives reliable results in high-conductivity or near-isoelectric samples, non-aqueous media and low electric fields, where classical Doppler methods lose signal quality.
What is the Phase Analysis Light Scattering Zeta Potential Analyzer?
A zeta potential analyzer using phase analysis light scattering (PALS) to measure very small electrophoretic mobilities. It gives reliable results in high-conductivity or near-isoelectric samples, non-aqueous media and low electric fields, where classical Doppler methods lose signal quality.
Overview
PALS tracks the phase of the scattered light relative to the reference beam over time, which is far more sensitive to slow particle motion than the frequency shift measured by classical laser Doppler electrophoresis. This allows low applied fields, reducing heating, electrode polarisation and sample degradation, and makes it possible to measure mobilities near zero at the isoelectric point. Instruments of this type are suited to high-conductivity buffers up to about 200 mS/cm, to hydrocarbons and alcohols with low dielectric constants, and to proteins in physiological media. Field-reversal sequences combine fast and slow reversal to separate electro-osmotic flow from true mobility. Sample volume is typically 0.75 mL in a disposable capillary cell, with temperature control from 0 to 90 °C.
How does it work?
Charged particles in a liquid are surrounded by an electrical double layer. The zeta potential is the potential at the slipping plane of this layer, and cannot be measured directly. Electrophoretic light scattering applies an electric field and measures particle velocity from the Doppler shift of scattered laser light; electrophoretic mobility is then converted to zeta potential by the Smoluchowski or Hückel approximation, or the Henry function for intermediate cases. Phase analysis light scattering improves sensitivity by measuring phase rather than frequency shift. Streaming potential instruments force electrolyte through a capillary or plug and measure the generated potential difference for solids. Electroacoustic methods detect sound waves generated by an applied alternating field in concentrated suspensions. Key components include the laser, electrodes and cell, temperature control and often a titrator.
What are the key features?
- Phase analysis light scattering detection for near-zero mobility
- Low-field operation to limit heating and electrode reactions
- Fast and slow field reversal for electro-osmosis correction
- Operation in buffers up to about 200 mS/cm
- Non-aqueous solvent capability with dielectric constant input
- Disposable capillary cells with gold-plated electrodes
What are the technical specifications?
A typical phase analysis light scattering zeta potential analyzer configuration offers mobility range of ±20 µm·cm/V·s, mobility sensitivity of ≤ 0.005 µm·cm/V·s, zeta potential range of −500 to +500 mV, measurement principle of PALS with field reversal, laser of 633 nm or 660 nm, ≥ 10 mW and applied field of Low-field, 5–20 V/cm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Phase Analysis Light Scattering Zeta Potential Analyzer is used in protein and monoclonal antibody formulation, samples near the isoelectric point, high-salt buffers and physiological media, non-aqueous dispersions in oils and alcohols and liposome and lipid nanoparticle studies. Across the wider Zeta Potential Analyzers class, laboratories also deploy it for colloidal stability of emulsions and suspensions, protein and biologic formulation screening and water and wastewater coagulation control.
Which standards and certifications apply?
Relevant standards and methods include ISO 13099-1, ISO 13099-2, ISO 13099-3, ASTM D4187, GB/T 32671 and ISO 13320. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Zeta potential depends on pH, ionic strength, temperature and sample history, so each report should state dispersant, pH, conductivity and temperature. Use low-conductivity, filtered dispersants and avoid bubbles at the electrodes; high salt can cause electrode polarisation and sample heating. Verify performance periodically using a zeta potential transfer standard, typically around −42 mV, and follow the supplier's interval. Clean cells thoroughly, since contamination and electrode degradation alter results. Gold or palladium electrodes and disposable capillary cells simplify maintenance. For regulated use, carry out IQ/OQ/PQ and maintain audit trails. Report the model used to convert mobility to zeta potential.
How do I select the right Phase Analysis Light Scattering Zeta Potential Analyzer?
Select PALS when samples have low mobility, high salt or low dielectric constant solvents, or when heating must be minimised, as in biologics and non-aqueous formulations. Specify conductivity range, solvent dielectric constants, sample volume limits, pH titration needs and compliance software. For simple dilute aqueous colloids, the standard electrophoretic variant is usually sufficient.
How does it compare with other Zeta Potential Analyzers variants?
Begin with the sample type. Dilute colloids and macromolecules suit electrophoretic light scattering; very low-mobility or high-conductivity samples benefit from phase analysis light scattering. Concentrated opaque suspensions, such as slurries, need electroacoustic methods, and flat or fibrous solids need streaming potential. If isoelectric point or pH dependence is required, choose a system with an automatic titrator. Check the required size range, conductivity limits, minimum sample volume and whether non-aqueous solvents are used, since the dielectric constant must be known. Decide if zeta potential alone is enough or whether combined size measurement is needed. Also weigh software validation support, cell durability and cost of disposable cells, and whether ISO 13099 conformity is expected in your methods.
Full specifications
| Mobility range | ±20 µm·cm/V·s |
|---|---|
| Mobility sensitivity | ≤ 0.005 µm·cm/V·s |
| Zeta potential range | −500 to +500 mV |
| Measurement principle | PALS with field reversal |
| Laser | 633 nm or 660 nm, ≥ 10 mW |
| Applied field | Low-field, 5–20 V/cm |
| Conductivity range | 0–200 mS/cm |
| Temperature range | 0–90 °C, ±0.1 °C |
| Sample volume | 0.75 mL |
| Size range (particles) | 3 nm–100 µm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Protein and monoclonal antibody formulation
- Samples near the isoelectric point
- High-salt buffers and physiological media
- Non-aqueous dispersions in oils and alcohols
- Liposome and lipid nanoparticle studies
Key features
- Phase analysis light scattering detection for near-zero mobility
- Low-field operation to limit heating and electrode reactions
- Fast and slow field reversal for electro-osmosis correction
- Operation in buffers up to about 200 mS/cm
- Non-aqueous solvent capability with dielectric constant input
- Disposable capillary cells with gold-plated electrodes
Frequently asked questions about Phase Analysis Light Scattering Zeta Potential Analyzer
PALS measures phase drift, which is more sensitive to slow motion, allowing low fields and reliable mobility near zero. This reduces heating and electrode degradation and improves results for proteins and high-salt samples.
Yes, provided solvent compatibility with cell materials is checked and the dielectric constant and viscosity are entered. Low-dielectric solvents give small mobilities, which is where PALS sensitivity helps most.
Titrate pH stepwise with acid or base, measure mobility at each pH, and find the pH where the curve crosses zero. PALS sensitivity gives a sharper crossing point because mobilities near zero remain measurable.
A large absolute zeta potential, commonly beyond ±30 mV, indicates strong electrostatic repulsion and usually good colloidal stability. Values near zero suggest particles can approach and aggregate. The guideline depends on whether steric stabilisers also contribute.
The isoelectric point is the pH at which zeta potential is zero and colloids are least stable. It is found by titrating the sample across a pH range with acid or base and recording zeta potential at each step, usually with an automatic titrator.
Zeta potential changes with pH, ionic strength and composition of the medium. A number without these conditions cannot be reproduced or compared, so method records must include dispersant, pH, conductivity and temperature.
Related models




Electroacoustic Zeta Potential Analyzer for Concentrated Suspensions
浓悬浮液电声法 Zeta 电位分析仪
- CE (to be confirmed)
- +1