Glovebox Vacuum System
手套箱真空系统
- SKU VAS-0006
- Vacuum Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pump type | Oil-free diaphragm or scroll |
|---|---|
| Ultimate pressure | About 10–1 mbar |
| Antechamber volume | 5–60 L |
| Purge gas | Nitrogen or argon |
| Oxygen level target | < 1 ppm with cycles |
| Moisture target | < 1 ppm with cycles |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 21360
What is the Glovebox Vacuum System?
A glovebox vacuum system provides clean vacuum for antechamber purge cycles, transfer operations and internal tools. It protects the inert atmosphere from air and moisture while keeping oil out of the box.
What is the Glovebox Vacuum System?
A glovebox vacuum system provides clean vacuum for antechamber purge cycles, transfer operations and internal tools. It protects the inert atmosphere from air and moisture while keeping oil out of the box.
Overview
The glovebox vacuum system is built around the antechamber and any internal vacuum functions. It uses an oil-free diaphragm or scroll pump to avoid hydrocarbon contamination of the inert atmosphere, with valves and a controller to run the vacuum and purge cycles that reduce oxygen and moisture before transfer. A gauge monitors pressure, and a small buffer or reservoir may smooth the cycling. Some systems include a vacuum line inside the box for filtration, drying or sample preparation, protected by a trap and filter. Because the box atmosphere is precious and often monitored for oxygen and water at parts per million, cleanliness and leak-tightness are critical, and every component must be compatible with the inert gas and the solvents used. Recovery of the box atmosphere during purging is sometimes included to reduce gas consumption.
How does it work?
A vacuum system combines all components needed to produce and control reduced pressure for one application. The pump sets the base pressure and pumping speed, gauges measure the level, valves control the path, and a controller sequences pump-down, hold and vent. Traps, filters and condensers protect the pump from vapor, particles and corrosive gas, while tubing and fittings must have enough conductance not to restrict flow. Design starts from the required pressure, chamber volume, gas load and cycle time, and the components are matched so that no single part limits performance. A complete system usually includes over-pressure and over-temperature protection, and often data logging. Because the parts are selected to work together, installation, commissioning and troubleshooting are simpler than with separately sourced components.
What are the key features?
- Oil-free diaphragm or scroll pump for clean vacuum
- Valves and controller for vacuum and purge cycles
- Gauge to monitor antechamber pressure
- Internal vacuum line for filtration or drying
- Trap and filter to protect the pump
- Optional gas recovery during purging
What are the technical specifications?
A typical glovebox vacuum system configuration offers pump type of Oil-free diaphragm or scroll, ultimate pressure of About 10–1 mbar, antechamber volume of 5–60 L, purge gas of Nitrogen or argon, oxygen level target of < 1 ppm with cycles and moisture target of < 1 ppm with cycles. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Glovebox Vacuum System is used in antechamber purge and transfer, air-sensitive sample handling, battery and metal research, internal drying and filtration and inert atmosphere preparation. Across the wider Vacuum Systems class, laboratories also deploy it for freeze drying and lyophilization, rotary evaporation and distillation and vacuum filtration and aspiration.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 21360, ISO 27893, ISO 20485 and ISO 9001. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Commission the system by recording base pressure, pump-down time and leak-up rate, and repeat these checks at service intervals to detect degradation. Keep traps clean and cold, and replace filters before they block. Review the sequencing so that valves and pumps are not switched in a way that causes pressure shocks or oil backstreaming. Train operators on safe venting, especially for oil-sealed pumps, which must not be vented at speed or left pressurized. Follow IEC 61010-1 for electrical safety and any local pressure rules for vessels and piping. For regulated processes, document installation and operational qualification against the user requirement specification. Keep spare seals, valves and filter elements so that downtime stays short.
How do I select the right Glovebox Vacuum System?
Choose an oil-free glovebox vacuum system when the inert atmosphere must stay clean and cycles must be efficient. Confirm pump, trap, cycle control and whether gas recovery is worthwhile for your usage. In the RFQ, state box model, antechamber volume, gas and target purity.
How does it compare with other Vacuum Systems variants?
Define the process first: target pressure, chamber or vessel volume, gas and vapor composition, cycle time and whether operation is continuous or batch. Then choose the pump type and speed to meet the pressure and time, and add a booster if the volume is large. Select gauges for the range, typically a Pirani or capacitance gauge, and valves for automatic or manual sequencing. Specify traps or condensers for condensable vapor, filters for particles and corrosion-resistant wetted materials for aggressive gases. Confirm the controller features you need, such as ramps, interlocks and data logging. Check utilities, noise, footprint and whether the system must fit a fume hood or cleanroom. Finally, ask for pump-down curves and commissioning data so realistic expectations are set.
Full specifications
| Pump type | Oil-free diaphragm or scroll |
|---|---|
| Ultimate pressure | About 10–1 mbar |
| Antechamber volume | 5–60 L |
| Purge gas | Nitrogen or argon |
| Oxygen level target | < 1 ppm with cycles |
| Moisture target | < 1 ppm with cycles |
| Gauge | 0–1000 mbar |
| Internal line | Optional, with trap |
| Gas recovery | Optional |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Antechamber purge and transfer
- Air-sensitive sample handling
- Battery and metal research
- Internal drying and filtration
- Inert atmosphere preparation
Key features
- Oil-free diaphragm or scroll pump for clean vacuum
- Valves and controller for vacuum and purge cycles
- Gauge to monitor antechamber pressure
- Internal vacuum line for filtration or drying
- Trap and filter to protect the pump
- Optional gas recovery during purging
Frequently asked questions about Glovebox Vacuum System
Oil vapor would contaminate the inert atmosphere and raise oxygen and moisture levels. An oil-free diaphragm or scroll pump keeps the box clean and reduces maintenance inside the enclosure.
Usually two or three vacuum and refill cycles reach low oxygen and moisture. More cycles or a heated antechamber are used when purity requirements are strict.
Yes, with a protected internal line, a trap and a filter so no solvent or particles reach the pump. Keep the line short and use only compatible materials.
Typically a pump, gauges, valves, a controller, and traps or filters, plus tubing and fittings matched to the process. Options include boosters, condensers and data logging, depending on the application.
Measure base pressure, pump-down time from atmosphere and leak-up rate with the pump isolated, and record them at commissioning. Repeating the same test later shows whether seals, traps or the pump have degraded.
A matched system avoids conductance bottlenecks, valve sizing errors and control mismatches, so it reaches the specified pressure and cycle time reliably. It also simplifies commissioning and service.
Related models