

Vacuum Filtration System
真空过滤系统
- SKU VAS-0003
- Vacuum Systems
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Free-air flow rate | 20–100 L/min |
|---|---|
| Working vacuum | 100–10 mbar |
| Receiver volume | 1–10 L |
| Manifold positions | 1–6 or 12 |
| Wetted material | PP, PTFE or stainless steel |
| Filter diameter | 25–90 mm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 21360
What is the Vacuum Filtration System?
A vacuum filtration system combines a pump, receiver, trap and manifold to speed filtration of one or many samples. It provides repeatable vacuum for microfiltration, SPE and solids recovery in routine laboratories.
What is the Vacuum Filtration System?
A vacuum filtration system combines a pump, receiver, trap and manifold to speed filtration of one or many samples. It provides repeatable vacuum for microfiltration, SPE and solids recovery in routine laboratories.
Overview
The vacuum filtration system packages a diaphragm or water-ring pump with a receiver flask, a liquid trap and often a multi-place manifold and gauge. Free-air flow of 20 to 100 liters per minute gives rapid filtration, and a regulator or needle valve sets the vacuum so that different membranes and filter papers perform consistently. Wetted parts are usually polypropylene, PTFE or stainless steel, and a hydrophobic filter protects the pump from aerosol. The receiver catches filtrate and overflow, and a gauge shows the working vacuum. Larger systems may use a central pump serving several benches through a distribution manifold. These systems are used in environmental water testing, beverage microbiology, chemical analysis and particle counting, and they reduce the handling and time compared with gravity filtration.
How does it work?
A vacuum system combines all components needed to produce and control reduced pressure for one application. The pump sets the base pressure and pumping speed, gauges measure the level, valves control the path, and a controller sequences pump-down, hold and vent. Traps, filters and condensers protect the pump from vapor, particles and corrosive gas, while tubing and fittings must have enough conductance not to restrict flow. Design starts from the required pressure, chamber volume, gas load and cycle time, and the components are matched so that no single part limits performance. A complete system usually includes over-pressure and over-temperature protection, and often data logging. Because the parts are selected to work together, installation, commissioning and troubleshooting are simpler than with separately sourced components.
What are the key features?
- Free-air flow of 20–100 L/min for rapid filtration
- Receiver flask and liquid trap for overflow protection
- Regulator or needle valve for consistent vacuum
- Optional multi-place manifold with individual valves
- Hydrophobic filter to protect the pump
- PP, PTFE or stainless steel wetted parts
What are the technical specifications?
A typical vacuum filtration system configuration offers free-air flow rate of 20–100 L/min, working vacuum of 100–10 mbar, receiver volume of 1–10 L, manifold positions of 1–6 or 12, wetted material of PP, PTFE or stainless steel and filter diameter of 25–90 mm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Vacuum Filtration System is used in environmental water filtration, beverage and food microbiology, chemical analysis sample prep, particle counting and sizing and solids recovery and washing. Across the wider Vacuum Systems class, laboratories also deploy it for freeze drying and lyophilization, rotary evaporation and distillation and vacuum filtration and aspiration.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 21360, ISO 27893, ISO 20485 and ISO 9001. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Commission the system by recording base pressure, pump-down time and leak-up rate, and repeat these checks at service intervals to detect degradation. Keep traps clean and cold, and replace filters before they block. Review the sequencing so that valves and pumps are not switched in a way that causes pressure shocks or oil backstreaming. Train operators on safe venting, especially for oil-sealed pumps, which must not be vented at speed or left pressurized. Follow IEC 61010-1 for electrical safety and any local pressure rules for vessels and piping. For regulated processes, document installation and operational qualification against the user requirement specification. Keep spare seals, valves and filter elements so that downtime stays short.
How do I select the right Vacuum Filtration System?
Choose a filtration system when filtration speed and repeatability matter and several samples may be run together. For occasional single filtrations, a pump and funnel suffice. In the RFQ, state flow, number of positions, filter size and material compatibility.
How does it compare with other Vacuum Systems variants?
Define the process first: target pressure, chamber or vessel volume, gas and vapor composition, cycle time and whether operation is continuous or batch. Then choose the pump type and speed to meet the pressure and time, and add a booster if the volume is large. Select gauges for the range, typically a Pirani or capacitance gauge, and valves for automatic or manual sequencing. Specify traps or condensers for condensable vapor, filters for particles and corrosion-resistant wetted materials for aggressive gases. Confirm the controller features you need, such as ramps, interlocks and data logging. Check utilities, noise, footprint and whether the system must fit a fume hood or cleanroom. Finally, ask for pump-down curves and commissioning data so realistic expectations are set.
Full specifications
| Free-air flow rate | 20–100 L/min |
|---|---|
| Working vacuum | 100–10 mbar |
| Receiver volume | 1–10 L |
| Manifold positions | 1–6 or 12 |
| Wetted material | PP, PTFE or stainless steel |
| Filter diameter | 25–90 mm |
| Gauge | Analog or digital |
| Regulation | Needle valve or regulator |
| Power supply | 220–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Environmental water filtration
- Beverage and food microbiology
- Chemical analysis sample prep
- Particle counting and sizing
- Solids recovery and washing
Key features
- Free-air flow of 20–100 L/min for rapid filtration
- Receiver flask and liquid trap for overflow protection
- Regulator or needle valve for consistent vacuum
- Optional multi-place manifold with individual valves
- Hydrophobic filter to protect the pump
- PP, PTFE or stainless steel wetted parts
Frequently asked questions about Vacuum Filtration System
A receiver flask catches liquid and a hydrophobic filter blocks aerosol. Empty the receiver regularly, especially during foaming filtrations, and replace the filter when wet.
Yes, with a needle valve or regulator and a gauge. Adjusting vacuum protects fragile membranes and prevents fine particles from being pulled through the filter.
Yes, with a compatible membrane and a clean receiver. Use 0.45 or 0.22 micrometer membranes and an all-glass or PTFE path to avoid extractables.
Typically a pump, gauges, valves, a controller, and traps or filters, plus tubing and fittings matched to the process. Options include boosters, condensers and data logging, depending on the application.
Measure base pressure, pump-down time from atmosphere and leak-up rate with the pump isolated, and record them at commissioning. Repeating the same test later shows whether seals, traps or the pump have degraded.
A matched system avoids conductance bottlenecks, valve sizing errors and control mismatches, so it reaches the specified pressure and cycle time reliably. It also simplifies commissioning and service.
Related models





