Central Laboratory Vacuum System
中央实验室真空系统
- SKU VAS-0005
- Vacuum Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- PED compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Pump type | Dry, water-ring or oil-sealed |
|---|---|
| Header pressure | About 100–20 mbar |
| Number of outlets | 4–50 |
| Receiver volume | 50–500 L |
| Pipe bore | 25–50 mm |
| Pump redundancy | Yes, lead-standby option |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61326-1, ISO 21360
What is the Central Laboratory Vacuum System?
A central laboratory vacuum system serves many benches and instruments from one pump and distribution network. It provides reliable vacuum throughout the building with a single service point and reduces noise and clutter.
What is the Central Laboratory Vacuum System?
A central laboratory vacuum system serves many benches and instruments from one pump and distribution network. It provides reliable vacuum throughout the building with a single service point and reduces noise and clutter.
Overview
The central vacuum system uses one or more pumps located in a service area, connected through piping and distribution manifolds to multiple benches, fume hoods and instruments. Pumps may be dry, water-ring or oil-sealed, and redundancy is often built in so that maintenance or failure of one pump does not stop the laboratory. A receiver tank buffers demand, and traps and filters protect the pumps from condensate and particles. Gauges or transmitters monitor the header pressure, and each bench has a valve or regulator to set its own level. The design reduces noise and heat in the working area, saves bench space and concentrates maintenance in one place. Sizing must consider simultaneous demand and pressure drop through long pipe runs, since poor conductance is the common cause of weak vacuum at distant benches.
How does it work?
A vacuum system combines all components needed to produce and control reduced pressure for one application. The pump sets the base pressure and pumping speed, gauges measure the level, valves control the path, and a controller sequences pump-down, hold and vent. Traps, filters and condensers protect the pump from vapor, particles and corrosive gas, while tubing and fittings must have enough conductance not to restrict flow. Design starts from the required pressure, chamber volume, gas load and cycle time, and the components are matched so that no single part limits performance. A complete system usually includes over-pressure and over-temperature protection, and often data logging. Because the parts are selected to work together, installation, commissioning and troubleshooting are simpler than with separately sourced components.
What are the key features?
- One or more pumps in a remote service area
- Piping and distribution manifolds to many benches
- Receiver tank to buffer demand fluctuations
- Traps and filters protecting the pumps
- Header pressure gauge or transmitter
- Redundancy so maintenance does not stop work
What are the technical specifications?
A typical central laboratory vacuum system configuration offers pump type of Dry, water-ring or oil-sealed, header pressure of About 100–20 mbar, number of outlets of 4–50, receiver volume of 50–500 L, pipe bore of 25–50 mm and pump redundancy of Yes, lead-standby option. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Central Laboratory Vacuum System is used in multi-bench laboratory vacuum supply, fume hood suction lines, instrument house vacuum, teaching laboratory distribution and pilot plant vacuum network. Across the wider Vacuum Systems class, laboratories also deploy it for freeze drying and lyophilization, rotary evaporation and distillation and vacuum filtration and aspiration.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61326-1, ISO 21360, ISO 27893, ISO 20485 and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and PED compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Commission the system by recording base pressure, pump-down time and leak-up rate, and repeat these checks at service intervals to detect degradation. Keep traps clean and cold, and replace filters before they block. Review the sequencing so that valves and pumps are not switched in a way that causes pressure shocks or oil backstreaming. Train operators on safe venting, especially for oil-sealed pumps, which must not be vented at speed or left pressurized. Follow IEC 61010-1 for electrical safety and any local pressure rules for vessels and piping. For regulated processes, document installation and operational qualification against the user requirement specification. Keep spare seals, valves and filter elements so that downtime stays short.
How do I select the right Central Laboratory Vacuum System?
Choose a central system for a large laboratory where many benches need vacuum, and plan for redunancy and service access. For a single bench, a local pump is simpler. In the RFQ, state outlet count, simultaneous demand, pipe route, pressure target and redundancy needs.
How does it compare with other Vacuum Systems variants?
Define the process first: target pressure, chamber or vessel volume, gas and vapor composition, cycle time and whether operation is continuous or batch. Then choose the pump type and speed to meet the pressure and time, and add a booster if the volume is large. Select gauges for the range, typically a Pirani or capacitance gauge, and valves for automatic or manual sequencing. Specify traps or condensers for condensable vapor, filters for particles and corrosion-resistant wetted materials for aggressive gases. Confirm the controller features you need, such as ramps, interlocks and data logging. Check utilities, noise, footprint and whether the system must fit a fume hood or cleanroom. Finally, ask for pump-down curves and commissioning data so realistic expectations are set.
Full specifications
| Pump type | Dry, water-ring or oil-sealed |
|---|---|
| Header pressure | About 100–20 mbar |
| Number of outlets | 4–50 |
| Receiver volume | 50–500 L |
| Pipe bore | 25–50 mm |
| Pump redundancy | Yes, lead-standby option |
| Monitoring | Header gauge or transmitter |
| Traps | Liquid and particle |
| Power supply | 380 V three-phase |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Multi-bench laboratory vacuum supply
- Fume hood suction lines
- Instrument house vacuum
- Teaching laboratory distribution
- Pilot plant vacuum network
Key features
- One or more pumps in a remote service area
- Piping and distribution manifolds to many benches
- Receiver tank to buffer demand fluctuations
- Traps and filters protecting the pumps
- Header pressure gauge or transmitter
- Redundancy so maintenance does not stop work
Frequently asked questions about Central Laboratory Vacuum System
Pressure drop in long or narrow piping reduces vacuum at distant outlets. Use a larger bore, shorter runs and a header that is generously sized, and check for closed or partly blocked valves.
For critical laboratories, yes. A lead-standby arrangement lets one pump be serviced while the other maintains vacuum, avoiding disruption to ongoing work.
With traps at the benches or on the header, plus a receiver tank and filters. Drain traps regularly, and slope piping toward them so liquid does not pool in the lines.
Typically a pump, gauges, valves, a controller, and traps or filters, plus tubing and fittings matched to the process. Options include boosters, condensers and data logging, depending on the application.
Measure base pressure, pump-down time from atmosphere and leak-up rate with the pump isolated, and record them at commissioning. Repeating the same test later shows whether seals, traps or the pump have degraded.
A matched system avoids conductance bottlenecks, valve sizing errors and control mismatches, so it reaches the specified pressure and cycle time reliably. It also simplifies commissioning and service.
Related models