Online TOC Analyzer for Surface Water and Effluent Monitoring — product photo

Online TOC Analyzer for Surface Water and Effluent Monitoring

地表水与排放水在线 TOC 分析仪

  • SKU TOC-0003
  • TOC Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • Chinese environmental monitoring instrument type approval (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Oxidation methodUV-persulfate or catalytic combustion
Measuring range (TOC)0–200 mg/L (extendable to 2000 mg/L)
Measurement cycle10–60 min
Repeatability≤ 3% of reading
Reagent consumptionAbout 2 L persulfate and acid per month
Calibration intervalAutomatic, programmable 1–30 days
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8245, ASTM D4839, ASTM D5173

What is the Online TOC Analyzer for Surface Water and Effluent Monitoring?

An unattended TOC analyzer installed at river stations, intake works or plant outfalls, reporting organic carbon every 10 to 60 minutes. It fits regulators and plant operators who need continuous data, alarms and early warning rather than periodic grab-sample results.

What is the Online TOC Analyzer for Surface Water and Effluent Monitoring?

An unattended TOC analyzer installed at river stations, intake works or plant outfalls, reporting organic carbon every 10 to 60 minutes. It fits regulators and plant operators who need continuous data, alarms and early warning rather than periodic grab-sample results.

Overview

This variant is built for continuous duty with a sample conditioning stage, which can include a sedimentation or filtration pre-treatment, peristaltic pumps, automatic calibration and reagent reservoirs sized for 30 days of operation. Oxidation is by UV-persulfate or combustion depending on matrix, with a typical range of 0 to 200 mg/L that can be extended to 2000 mg/L. The cabinet is rated IP54 or higher, includes a temperature-controlled enclosure and supports 4–20 mA, Modbus RTU or TCP output for SCADA and environmental data platforms. Automatic zero and span checks run on a schedule, and fault alarms cover reagent, flow and lamp status. Measurement cycles of 10–60 minutes allow tracking of discharge events and intake contamination. Regular service, including pump tubing, reagent refill and optical cleaning, is typically required every two to four weeks.

How does it work?

A TOC analyzer converts all organic carbon in a water sample to CO2 and quantifies the gas. Two oxidation routes dominate. High-temperature catalytic combustion injects the sample into a furnace at 680–900 °C containing a platinum or similar catalyst, which also handles particulates and difficult compounds. UV-persulfate oxidation adds sodium persulfate and irradiates the sample with UV at 185 and 254 nm to generate hydroxyl radicals. Inorganic carbon is removed first by acidification and sparging, or measured separately to give TOC by difference. The CO2 is carried by purified air or oxygen to a non-dispersive infrared detector, or measured by membrane conductometry in low-level systems. Peak area is integrated and converted to concentration using a multi-point calibration against potassium hydrogen phthalate standards.

What are the key features?

  • Continuous duty with measurement cycles from 10 to 60 minutes
  • Sample conditioning with filtration or sedimentation pre-treatment for turbid water
  • Scheduled automatic zero, span and cleaning routines
  • 4–20 mA, Modbus and relay outputs for SCADA and alarm integration
  • Reagent capacity for about 30 days of unattended operation
  • IP54 enclosure with temperature-controlled interior for station installation

What are the technical specifications?

A typical online toc analyzer for surface water and effluent monitoring configuration offers oxidation method of UV-persulfate or catalytic combustion, measuring range (TOC) of 0–200 mg/L (extendable to 2000 mg/L), measurement cycle of 10–60 min, repeatability of ≤ 3% of reading, reagent consumption of About 2 L persulfate and acid per month and calibration interval of Automatic, programmable 1–30 days. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Online TOC Analyzer for Surface Water and Effluent Monitoring is used in river and lake water quality stations, drinking water intake early warning, industrial outfall compliance monitoring and wastewater treatment plant process control. Across the wider TOC Analyzers class, laboratories also deploy it for drinking water treatment monitoring, wastewater discharge compliance and surface water and groundwater surveys.

Which standards and certifications apply?

Relevant standards and methods include ISO 8245, ASTM D4839, ASTM D5173, ASTM D5904, USP <643>, Ph. Eur. 2.2.44, HJ 501 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Chinese environmental monitoring instrument type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the analyzer on a stable bench with clean, dry carrier gas at 99.99% purity or a zero-air generator, and provide ventilation for exhaust. Calibrate at least monthly with potassium hydrogen phthalate and verify with sodium carbonate and a blank each run. Keep glassware organic-free and use ultrapure water blanks, since ambient organics cause high blanks. Replace combustion catalyst, halogen scrubbers and persulfate reagent on the schedule stated by the manufacturer. For regulated laboratories, confirm software audit trails and user access levels, and run system suitability with sucrose and benzoquinone to check oxidation efficiency where USP <643> applies.

How do I select the right Online TOC Analyzer for Surface Water and Effluent Monitoring?

Select the online variant when regulations or operations need continuous organic carbon data, alarms or early-warning coverage. Choose a laboratory analyzer if sampling is infrequent. In an RFQ, give sample turbidity and solids, TOC range, communication protocol, site power and temperature conditions, and whether the local environmental authority requires type-approved equipment.

How does it compare with other TOC Analyzers variants?

The decisive parameters are sample matrix, measuring range and operating mode. Wastewater and effluents with particulates, high salt or high carbon load call for high-temperature combustion with a robust injection system and dilution capability. Drinking water and cleaner surface water, typically below 20 mg/L, are well served by UV-persulfate or low-temperature oxidation with sub-0.1 mg/L resolution. Semiconductor and pharmaceutical purified water need online ppb-level sensors with conductivity-based detection. Decide whether you need laboratory batch analysis with an autosampler or continuous online data. If nitrogen loading matters for discharge permits, a combined TOC-TN configuration saves a second instrument. Also check the method you must follow, such as ISO 8245 or USP <643>, and the consumables cost of gases, catalyst and reagents.

Full specifications

Full specifications
Oxidation methodUV-persulfate or catalytic combustion
Measuring range (TOC)0–200 mg/L (extendable to 2000 mg/L)
Measurement cycle10–60 min
Repeatability≤ 3% of reading
Reagent consumptionAbout 2 L persulfate and acid per month
Calibration intervalAutomatic, programmable 1–30 days
Output signals4–20 mA, RS-485 Modbus, relays
Enclosure ratingIP54
Ambient temperature5–40 °C
Power supplyAC 220 V, 50 Hz, 400 VA

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • River and lake water quality stations
  • Drinking water intake early warning
  • Industrial outfall compliance monitoring
  • Wastewater treatment plant process control

Key features

  • Continuous duty with measurement cycles from 10 to 60 minutes
  • Sample conditioning with filtration or sedimentation pre-treatment for turbid water
  • Scheduled automatic zero, span and cleaning routines
  • 4–20 mA, Modbus and relay outputs for SCADA and alarm integration
  • Reagent capacity for about 30 days of unattended operation
  • IP54 enclosure with temperature-controlled interior for station installation

Frequently asked questions about Online TOC Analyzer for Surface Water and Effluent Monitoring

Expect a service visit every two to four weeks to refill reagents, replace pump tubing, clean the sample path and check calibration. Annual preventive maintenance covers the UV lamp or furnace components. Turbid sites may need more frequent filter cleaning.