Online TOC Analyzer for Surface Water and Effluent Monitoring
地表水与排放水在线 TOC 分析仪
- SKU TOC-0003
- TOC Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Chinese environmental monitoring instrument type approval (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Oxidation method | UV-persulfate or catalytic combustion |
|---|---|
| Measuring range (TOC) | 0–200 mg/L (extendable to 2000 mg/L) |
| Measurement cycle | 10–60 min |
| Repeatability | ≤ 3% of reading |
| Reagent consumption | About 2 L persulfate and acid per month |
| Calibration interval | Automatic, programmable 1–30 days |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 8245, ASTM D4839, ASTM D5173
What is the Online TOC Analyzer for Surface Water and Effluent Monitoring?
An unattended TOC analyzer installed at river stations, intake works or plant outfalls, reporting organic carbon every 10 to 60 minutes. It fits regulators and plant operators who need continuous data, alarms and early warning rather than periodic grab-sample results.
What is the Online TOC Analyzer for Surface Water and Effluent Monitoring?
An unattended TOC analyzer installed at river stations, intake works or plant outfalls, reporting organic carbon every 10 to 60 minutes. It fits regulators and plant operators who need continuous data, alarms and early warning rather than periodic grab-sample results.
Overview
This variant is built for continuous duty with a sample conditioning stage, which can include a sedimentation or filtration pre-treatment, peristaltic pumps, automatic calibration and reagent reservoirs sized for 30 days of operation. Oxidation is by UV-persulfate or combustion depending on matrix, with a typical range of 0 to 200 mg/L that can be extended to 2000 mg/L. The cabinet is rated IP54 or higher, includes a temperature-controlled enclosure and supports 4–20 mA, Modbus RTU or TCP output for SCADA and environmental data platforms. Automatic zero and span checks run on a schedule, and fault alarms cover reagent, flow and lamp status. Measurement cycles of 10–60 minutes allow tracking of discharge events and intake contamination. Regular service, including pump tubing, reagent refill and optical cleaning, is typically required every two to four weeks.
How does it work?
A TOC analyzer converts all organic carbon in a water sample to CO2 and quantifies the gas. Two oxidation routes dominate. High-temperature catalytic combustion injects the sample into a furnace at 680–900 °C containing a platinum or similar catalyst, which also handles particulates and difficult compounds. UV-persulfate oxidation adds sodium persulfate and irradiates the sample with UV at 185 and 254 nm to generate hydroxyl radicals. Inorganic carbon is removed first by acidification and sparging, or measured separately to give TOC by difference. The CO2 is carried by purified air or oxygen to a non-dispersive infrared detector, or measured by membrane conductometry in low-level systems. Peak area is integrated and converted to concentration using a multi-point calibration against potassium hydrogen phthalate standards.
What are the key features?
- Continuous duty with measurement cycles from 10 to 60 minutes
- Sample conditioning with filtration or sedimentation pre-treatment for turbid water
- Scheduled automatic zero, span and cleaning routines
- 4–20 mA, Modbus and relay outputs for SCADA and alarm integration
- Reagent capacity for about 30 days of unattended operation
- IP54 enclosure with temperature-controlled interior for station installation
What are the technical specifications?
A typical online toc analyzer for surface water and effluent monitoring configuration offers oxidation method of UV-persulfate or catalytic combustion, measuring range (TOC) of 0–200 mg/L (extendable to 2000 mg/L), measurement cycle of 10–60 min, repeatability of ≤ 3% of reading, reagent consumption of About 2 L persulfate and acid per month and calibration interval of Automatic, programmable 1–30 days. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online TOC Analyzer for Surface Water and Effluent Monitoring is used in river and lake water quality stations, drinking water intake early warning, industrial outfall compliance monitoring and wastewater treatment plant process control. Across the wider TOC Analyzers class, laboratories also deploy it for drinking water treatment monitoring, wastewater discharge compliance and surface water and groundwater surveys.
Which standards and certifications apply?
Relevant standards and methods include ISO 8245, ASTM D4839, ASTM D5173, ASTM D5904, USP <643>, Ph. Eur. 2.2.44, HJ 501 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Chinese environmental monitoring instrument type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a stable bench with clean, dry carrier gas at 99.99% purity or a zero-air generator, and provide ventilation for exhaust. Calibrate at least monthly with potassium hydrogen phthalate and verify with sodium carbonate and a blank each run. Keep glassware organic-free and use ultrapure water blanks, since ambient organics cause high blanks. Replace combustion catalyst, halogen scrubbers and persulfate reagent on the schedule stated by the manufacturer. For regulated laboratories, confirm software audit trails and user access levels, and run system suitability with sucrose and benzoquinone to check oxidation efficiency where USP <643> applies.
How do I select the right Online TOC Analyzer for Surface Water and Effluent Monitoring?
Select the online variant when regulations or operations need continuous organic carbon data, alarms or early-warning coverage. Choose a laboratory analyzer if sampling is infrequent. In an RFQ, give sample turbidity and solids, TOC range, communication protocol, site power and temperature conditions, and whether the local environmental authority requires type-approved equipment.
How does it compare with other TOC Analyzers variants?
The decisive parameters are sample matrix, measuring range and operating mode. Wastewater and effluents with particulates, high salt or high carbon load call for high-temperature combustion with a robust injection system and dilution capability. Drinking water and cleaner surface water, typically below 20 mg/L, are well served by UV-persulfate or low-temperature oxidation with sub-0.1 mg/L resolution. Semiconductor and pharmaceutical purified water need online ppb-level sensors with conductivity-based detection. Decide whether you need laboratory batch analysis with an autosampler or continuous online data. If nitrogen loading matters for discharge permits, a combined TOC-TN configuration saves a second instrument. Also check the method you must follow, such as ISO 8245 or USP <643>, and the consumables cost of gases, catalyst and reagents.
Full specifications
| Oxidation method | UV-persulfate or catalytic combustion |
|---|---|
| Measuring range (TOC) | 0–200 mg/L (extendable to 2000 mg/L) |
| Measurement cycle | 10–60 min |
| Repeatability | ≤ 3% of reading |
| Reagent consumption | About 2 L persulfate and acid per month |
| Calibration interval | Automatic, programmable 1–30 days |
| Output signals | 4–20 mA, RS-485 Modbus, relays |
| Enclosure rating | IP54 |
| Ambient temperature | 5–40 °C |
| Power supply | AC 220 V, 50 Hz, 400 VA |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- River and lake water quality stations
- Drinking water intake early warning
- Industrial outfall compliance monitoring
- Wastewater treatment plant process control
Key features
- Continuous duty with measurement cycles from 10 to 60 minutes
- Sample conditioning with filtration or sedimentation pre-treatment for turbid water
- Scheduled automatic zero, span and cleaning routines
- 4–20 mA, Modbus and relay outputs for SCADA and alarm integration
- Reagent capacity for about 30 days of unattended operation
- IP54 enclosure with temperature-controlled interior for station installation
Frequently asked questions about Online TOC Analyzer for Surface Water and Effluent Monitoring
Expect a service visit every two to four weeks to refill reagents, replace pump tubing, clean the sample path and check calibration. Annual preventive maintenance covers the UV lamp or furnace components. Turbid sites may need more frequent filter cleaning.
Yes, with pre-treatment. A sedimentation chamber or self-cleaning filter removes coarse solids, and a wide-bore sample path reduces clogging. Note that filtering removes particulate organic carbon, so the reading represents mainly dissolved organic carbon unless a homogenizing sampler is used.
Yes. Analog 4–20 mA and digital Modbus outputs are standard, and most stations connect through a data logger to regulatory platforms. Confirm the required protocol, such as HJ 212 in China, with the supplier before ordering.
It measures the total mass concentration of carbon bound in organic compounds, reported in mg/L or µg/L. Organic carbon is oxidized to CO2 and detected, so the result covers dissolved and, with suitable sample handling, particulate organic matter regardless of its chemical identity.
NPOC acidifies and sparges the sample to remove inorganic carbon, then measures the remaining non-purgeable organic carbon. TOC by difference measures total carbon and inorganic carbon separately and subtracts them. NPOC is more accurate when inorganic carbon is high, but loses volatile organics.
High-temperature catalytic combustion is usually preferred for wastewater because it oxidizes particulates, surfactants and refractory organics that UV-persulfate may only partially oxidize. It tolerates high salt and carbon loads when fitted with a suitable injector, dilution and salt-handling components.
Related models