Volumetric Karl Fischer Titrator
容量法卡尔费休水分滴定仪
- SKU TIT-0003
- Titrators
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 100 ppm to 100% water |
|---|---|
| Burette volume | 5 mL or 10 mL |
| Dosing resolution | 1/20,000 burette volume |
| Titrant concentration | 2 or 5 mg H2O/mL |
| Repeatability (10 mg water) | RSD ≤ 0.5% |
| Indicator electrode | Double platinum pin |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D664, ASTM D974, ASTM D6304
What is the Volumetric Karl Fischer Titrator?
A volumetric Karl Fischer titrator dispenses a one-component or two-component iodine reagent from a burette to the water endpoint. It is the preferred choice for samples with roughly 0.1% to 100% water, such as sugars, foods, pharmaceutical materials, solvents and industrial chemicals.
What is the Volumetric Karl Fischer Titrator?
A volumetric Karl Fischer titrator dispenses a one-component or two-component iodine reagent from a burette to the water endpoint. It is the preferred choice for samples with roughly 0.1% to 100% water, such as sugars, foods, pharmaceutical materials, solvents and industrial chemicals.
Overview
The instrument combines a precision piston burette, a sealed titration vessel with a double platinum indicator electrode and a stirrer. Titrant strength, typically 2 or 5 mg water per mL, is determined against a water standard or sodium tartrate dihydrate, since it changes with time. Larger sample masses and high water contents are handled easily, which is why the technique is used for hygroscopic solids and products with several percent water. The vessel is pre-titrated to dryness before each sample. Methods can include stirring delay time, extraction time for solids and drift correction. Auto-sample feeders and solvent exchange systems let the same cell process a series of samples, while a parallel oven attachment extends the technique to materials that cannot be dissolved.
How does it work?
A titrator combines a precision burette or coulometric generator electrode, a stirred titration vessel, a sensor and a control unit. In volumetric titration, a motor-driven piston burette dispenses titrant while a sensor, usually a pH glass electrode, redox platinum electrode or photometric probe, tracks the solution. The endpoint is identified as a preset potential or the inflection point of the titration curve, and the result is calculated from titrant volume, concentration and stoichiometry. In coulometric Karl Fischer titration, iodine is generated electrochemically at a generator electrode and the charge passed, according to Faraday's law, gives the mass of water directly without a burette. Dynamic dosing slows addition near the endpoint to improve accuracy, and automatic sample changers allow unattended series.
What are the key features?
- Piston burette with 5 or 10 mL volume and fine dosing resolution
- Automatic titer determination with stored standard mass and history
- Pre-titration to dryness and drift compensation before each determination
- Adjustable extraction and stirring time for slowly dissolving solids
- Optional solvent exchange station to automate cell rinsing and refilling
- Compatible with one-component and two-component reagents
What are the technical specifications?
A typical volumetric karl fischer titrator configuration offers measuring range of 100 ppm to 100% water, burette volume of 5 mL or 10 mL, dosing resolution of 1/20,000 burette volume, titrant concentration of 2 or 5 mg H2O/mL, repeatability (10 mg water) of RSD ≤ 0.5% and indicator electrode of Double platinum pin. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Volumetric Karl Fischer Titrator is used in water in sugars, confectionery and dairy powders, moisture in APIs and excipients, water in alcohols, ketones and solvents, moisture in greases and petroleum products and water in industrial chemicals and resins. Across the wider Titrators class, laboratories also deploy it for water determination in oils and solvents, acid and base number of petroleum products and chloride and salt content in food and water.
Which standards and certifications apply?
Relevant standards and methods include ASTM D664, ASTM D974, ASTM D6304, ASTM E203, ISO 760, USP <921> and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the titrator on a vibration-free bench away from drafts and direct sunlight. Standardize titrants regularly against a primary standard such as potassium hydrogen phthalate or sodium oxalate, and record the titer. Verify electrodes with buffers and check the burette volume gravimetrically at defined intervals. For Karl Fischer work, replace desiccant, keep the cell sealed, check drift before each series and verify with a certified water standard. Rinse tubing when changing titrants to avoid cross-contamination, and inspect piston seals and valves as part of preventive maintenance. Dispose of reagents, particularly pyridine-free Karl Fischer solutions and organic solvents, according to local waste rules.
How do I select the right Volumetric Karl Fischer Titrator?
Select this variant for routine water determination in samples above about 0.1% water, for large sample masses or for cost-effective high-throughput work. Choose the coulometric sibling for trace levels. In an RFQ, specify reagent type, burette size, need for a solvent exchange station or oven, and the pharmacopoeial or ASTM methods the laboratory follows, such as USP <921> method Ia.
How does it compare with other Titrators variants?
The decisive choice is the titration chemistry. Water in oils, solvents and solids calls for Karl Fischer, volumetric above about 0.1% water and coulometric below it. Acid and base number in petroleum products and general acid-base, redox, argentometric and complexometric titrations call for a potentiometric titrator. Consider sample throughput, because an automatic sample changer is justified beyond roughly 20 samples per day. Check burette resolution, available sensors and whether the software supports the standard methods you run, such as ASTM D664 or ASTM D6304. Also weigh solvent consumption and waste handling, reagent storage for moisture-sensitive titrants, and whether audit-trail and user management features are required for accredited or regulated work.
Full specifications
| Measuring range | 100 ppm to 100% water |
|---|---|
| Burette volume | 5 mL or 10 mL |
| Dosing resolution | 1/20,000 burette volume |
| Titrant concentration | 2 or 5 mg H2O/mL |
| Repeatability (10 mg water) | RSD ≤ 0.5% |
| Indicator electrode | Double platinum pin |
| Polarization current | 1–50 µA selectable |
| Titration vessel volume | 60–150 mL |
| Stirring speed | 0–2000 rpm |
| Data interface | USB, RS-232, Ethernet |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Water in sugars, confectionery and dairy powders
- Moisture in APIs and excipients
- Water in alcohols, ketones and solvents
- Moisture in greases and petroleum products
- Water in industrial chemicals and resins
Key features
- Piston burette with 5 or 10 mL volume and fine dosing resolution
- Automatic titer determination with stored standard mass and history
- Pre-titration to dryness and drift compensation before each determination
- Adjustable extraction and stirring time for slowly dissolving solids
- Optional solvent exchange station to automate cell rinsing and refilling
- Compatible with one-component and two-component reagents
Frequently asked questions about Volumetric Karl Fischer Titrator
Titrant is standardized by titrating a known mass of a water standard, sodium tartrate dihydrate (15.66% water), or pure water. The titer in mg water per mL is calculated from the result, and three replicate determinations with low scatter are normally required.
One-component reagents combine all chemistry in one bottle and are convenient for routine work. Two-component reagents separate solvent and titrant, giving faster titration, better stability and more suitability for difficult samples, but require two solutions.
Drift should be low and stable, commonly below 20 µg water per minute for volumetric cells. High drift indicates leaking seals, exhausted desiccant or wet solvent, and should be corrected before analysis to avoid bias in low-water results.
Volumetric Karl Fischer adds iodine-containing titrant from a burette and suits samples above roughly 0.1% water. Coulometric Karl Fischer generates iodine electrochemically and suits trace water from about 1 ppm to 5%, because it uses no burette and has lower detection limits.
The titrator monitors a sensor signal such as potential, pH or light transmission during titrant addition. The endpoint is either a preset signal value or the inflection point of the titration curve found by first or second derivative evaluation, which is more robust for weak acids or unknown samples.
Standardize titrants whenever a new batch is prepared and then at intervals set by stability, commonly weekly for sodium hydroxide and every few days for Karl Fischer titrant. Record the titer and investigate any drift, since titer errors transfer directly into every result.