Dynamic Mechanical Analyzer for Plastics — product photo

Dynamic Mechanical Analyzer for Plastics

塑料动态力学分析仪

  • SKU THA-0004
  • Thermal Analysis
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range−150 to 600 °C with cooling accessory
Frequency range0.001–200 Hz
Heating rate0.1–20 °C/min
Force range0.001–18 N
Strain resolutionAbout 1 nm
Deformation modes3-point bending, dual cantilever, tension, compression, shear
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 11357-1, ISO 11358-1, ISO 11359-1

What is the Dynamic Mechanical Analyzer for Plastics?

A dynamic mechanical analyzer applies an oscillating deformation to a plastic specimen and records storage modulus, loss modulus and damping against temperature or frequency. It detects the glass transition with the highest sensitivity of any thermal technique.

What is the Dynamic Mechanical Analyzer for Plastics?

A dynamic mechanical analyzer applies an oscillating deformation to a plastic specimen and records storage modulus, loss modulus and damping against temperature or frequency. It detects the glass transition with the highest sensitivity of any thermal technique.

Overview

The instrument clamps the specimen in a selected deformation geometry, most often three-point bending, dual cantilever, tension, compression or shear, and applies a small sinusoidal strain while measuring the resulting stress and phase lag. Storage modulus describes elastic response, loss modulus the viscous response, and their ratio gives the damping or loss tangent, whose peak position is taken as the glass transition. Temperature scans from well below to well above the transition show the softening of the amorphous phase and, in composites, the effect of fibre reinforcement and of the interphase. Frequency scans provide master curves through time-temperature superposition, which are used to predict long-term creep and stiffness behaviour. Specimen dimensions and clamping torque must be recorded because the modulus is calculated from geometry.

How does it work?

Each thermal analysis technique monitors a different physical property as temperature changes. Differential scanning calorimetry records heat flow and reveals glass transition, melting, crystallisation and cure. Thermogravimetry records mass and reveals decomposition and filler content. Thermomechanical analysis records dimensional change under a defined probe and load, giving the coefficient of linear thermal expansion and softening behaviour. Dynamic mechanical analysis applies an oscillating deformation and records storage modulus, loss modulus and damping, which are the most sensitive indicators of glass transition in composites. Heat deflection and Vicat instruments apply a defined load with a standard indenter and record the temperature at which a specified deflection is reached. Thermal conductivity methods measure steady-state or transient heat flow through the specimen.

What are the key features?

  • Bending, tension, compression and shear fixtures
  • Frequency range from 0.001 to 200 Hz
  • Damping peak evaluation for glass transition
  • Time-temperature superposition master curves
  • Temperature range with cooling accessory
  • Strain amplitude control for linear response

What are the technical specifications?

A typical dynamic mechanical analyzer for plastics configuration offers temperature range of −150 to 600 °C with cooling accessory, frequency range of 0.001–200 Hz, heating rate of 0.1–20 °C/min, force range of 0.001–18 N, strain resolution of About 1 nm and deformation modes of 3-point bending, dual cantilever, tension, compression, shear. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dynamic Mechanical Analyzer for Plastics is used in glass transition of composites and highly filled plastics, damping and stiffness over a temperature range, cure and crosslink density assessment and ageing and weathering effects on modulus. Across the wider Thermal Analysis class, laboratories also deploy it for glass transition and melting point determination, heat deflection and Vicat softening temperature testing and thermal expansion and coefficient of linear expansion.

Which standards and certifications apply?

Relevant standards and methods include ISO 11357-1, ISO 11358-1, ISO 11359-1, ISO 6721-1, ISO 306, ISO 75-1, ASTM D648, ASTM D1525, ASTM D4065 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Calibrate the temperature and the property scale with certified standards at the start of a series, and record heating and cooling rates because thermal history changes crystallinity and transitions for every technique. Condition specimens according to the product standard, usually 23 °C and 50% relative humidity, since absorbed moisture shifts results in polyamides and other hygroscopic plastics. Use specimens with parallel faces and uniform thickness, and avoid machining damage on the measuring surfaces. Purge gas protects against oxidation in calorimetry and thermogravimetry, while heat deflection and Vicat tests need a stable silicone oil bath and correct indenter geometry. Keep calibration certificates, raw curves and instrument logs for traceability.

How do I select the right Dynamic Mechanical Analyzer for Plastics?

Select dynamic mechanical analysis when the specification cites a glass transition by damping, when the material is a composite or highly filled compound, or when stiffness and damping must be known over a temperature or frequency range. Confirm the fixtures you require, because specimen preparation differs for each, and check that the strain range suits both stiff and soft grades.

How does it compare with other Thermal Analysis variants?

Start from the property the specification names. If the requirement is a glass transition or a melting point, differential scanning calorimetry is the usual method, while thermomechanical analysis is preferred when the transition must be expressed as a dimensional change or when the coefficient of thermal expansion is also needed. For composites, filled compounds and damping behaviour, dynamic mechanical analysis gives the clearest glass transition and is the standard reference for automotive and structural applications. Decomposition temperature, filler content and thermal stability require thermogravimetry. Heat deflection and Vicat temperatures are short-term, load-dependent indicators widely used in material specifications. Thermal conductivity is measured separately by transient or steady-state methods, and the technique chosen must match the conductivity range and specimen form.

Full specifications

Full specifications
Temperature range−150 to 600 °C with cooling accessory
Frequency range0.001–200 Hz
Heating rate0.1–20 °C/min
Force range0.001–18 N
Strain resolutionAbout 1 nm
Deformation modes3-point bending, dual cantilever, tension, compression, shear
Specimen dimensionsBars about 50 × 10 × 3 mm typical
Purge gasNitrogen or air, 50–200 mL/min
Power supply220 V, 50/60 Hz

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Glass transition of composites and highly filled plastics
  • Damping and stiffness over a temperature range
  • Cure and crosslink density assessment
  • Ageing and weathering effects on modulus

Key features

  • Bending, tension, compression and shear fixtures
  • Frequency range from 0.001 to 200 Hz
  • Damping peak evaluation for glass transition
  • Time-temperature superposition master curves
  • Temperature range with cooling accessory
  • Strain amplitude control for linear response

Frequently asked questions about Dynamic Mechanical Analyzer for Plastics

The technique measures the phase lag between applied strain and resulting stress, which is dominated by the mobility of polymer chains. Even a small fraction of mobile amorphous phase produces a measurable damping peak, so composites and crosslinked systems that show almost no signal in calorimetry are easily characterised.

Related models

All Thermal Analysis

Request a quotation for the Dynamic Mechanical Analyzer for Plastics

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote