Dry Heat Sterilizer

干热灭菌器

  • SKU STE-0005
  • Sterilization Equipment
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature rangeAmbient +10 to 250 °C
Sterilization temperature160–180 °C
Sterilization time60–120 min
Temperature uniformity±1 °C at 180 °C
Air circulationForced convection fan
Chamber volume50–300 L
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 17665-1, EN 285, ISO 11138-1

What is the Dry Heat Sterilizer?

A dry heat sterilizer uses hot air rather than steam to sterilize glassware, metal instruments and powders that steam would corrode, wet or fail to penetrate. It is also called a hot air oven.

What is the Dry Heat Sterilizer?

A dry heat sterilizer uses hot air rather than steam to sterilize glassware, metal instruments and powders that steam would corrode, wet or fail to penetrate. It is also called a hot air oven.

Overview

A dry heat sterilizer, commonly known as a hot air oven, sterilizes with circulated hot air at 160 to 180 degrees Celsius for one to two hours, or at higher temperatures for shorter times. Heat is transferred by conduction and convection, which is slower than moist heat, so cycles are longer and loads must be arranged to allow air to circulate between items. Dry heat is used for glassware, metal instruments, oils, greases and powders, and for items that steam cannot reach or would corrode. Forced convection improves temperature uniformity, and modern controllers run timed cycles with programmable ramp and cooling. Because no moisture is present, dry heat does not corrode sharp instruments and leaves no residue. Validation uses biological indicators with Bacillus atrophaeus spores, whose resistance is appropriate to dry heat.

How does it work?

Moist-heat sterilization kills organisms by coagulating and denaturing proteins and nucleic acids in the presence of saturated steam. The decisive conditions are temperature, pressure and time: at 121 degrees Celsius and about 1 bar gauge a standard cycle holds for 15 to 20 minutes, while 134 degrees Celsius achieves quicker cycles typical of clinical waste. Steam must contact every surface, so the chamber is purged of air by gravity displacement in simple units or by repeated vacuum pulses in more advanced ones. Dry heat kills by oxidation and requires higher temperature or longer time, often 160 to 180 degrees Celsius for one to two hours. Media preparators combine mixing, heating and in-vessel sterilization so that agar is prepared and sterilized in one vessel rather than in bottles.

What are the key features?

  • Forced-convection hot air at 160 to 180 degrees Celsius
  • Programmable ramp, hold and cooling cycles
  • Suitable for glassware, metal instruments and powders
  • No corrosion or residue from moisture
  • Biological indicator validation with Bacillus atrophaeus

What are the technical specifications?

A typical dry heat sterilizer configuration offers temperature range of Ambient +10 to 250 °C, sterilization temperature of 160–180 °C, sterilization time of 60–120 min, temperature uniformity of ±1 °C at 180 °C, air circulation of Forced convection fan and chamber volume of 50–300 L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dry Heat Sterilizer is used in sterilization of glassware and metal instruments, powder and oil sterilization, laboratories avoiding steam corrosion and preparation of dry labware for microbiology. Across the wider Sterilization Equipment class, laboratories also deploy it for sterilization of culture media and glassware, decontamination of microbiological waste and sterilization of instruments and labware.

Which standards and certifications apply?

Relevant standards and methods include ISO 17665-1, EN 285, ISO 11138-1, ISO 14937, ISO 7218 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Operators must be trained in safe loading, correct cycle selection and the risks of hot liquids and pressurized steam. Load items so that steam circulates freely; do not overfill baskets, and loosen closures on bottles and containers. Verify each cycle with physical indicators and temperature records, and confirm performance periodically with biological indicators such as Geobacillus stearothermophilus spores. Drain and clean the chamber, check the door gasket and strainer, and descale the generator on a schedule. Record maintenance and requalification, including chamber temperature mapping. Ensure adequate ventilation and drainage, and confirm that the electrical installation meets the manufacturer's requirements and IEC 61010-1.

How do I select the right Dry Heat Sterilizer?

Choose dry heat when steam would corrode, wet or fail to penetrate the load, such as powders, oils and dry glassware. In an RFQ specify temperature range, uniformity, chamber volume, programmability, data recording, and the biological indicator method used for validation.

How does it compare with other Sterilization Equipment variants?

Begin with the load and the required throughput. Small volumes of media, glassware and instruments suit a bench-top autoclave of 20 to 50 L, while a busy laboratory sterilizing large batches or waste may need a vertical or horizontal unit of 50 to 200 L or more. Confirm that the chamber size and basket arrangement fit your largest items and that the cycle type, gravity or pre-vacuum, removes air from porous loads and liquids. For media, a preparator reduces handling and improves consistency. Choose dry heat when steam would corrode instruments, wet powders or damage glassware. Check safety features such as door interlocks, pressure relief, overtemperature cut-out and cycle recording, and confirm that validation, biological indicators and service support are available.

Full specifications

Full specifications
Temperature rangeAmbient +10 to 250 °C
Sterilization temperature160–180 °C
Sterilization time60–120 min
Temperature uniformity±1 °C at 180 °C
Air circulationForced convection fan
Chamber volume50–300 L
ControlMicroprocessor with timer and program
SafetyOvertemperature protection, door interlock

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Sterilization of glassware and metal instruments
  • Powder and oil sterilization
  • Laboratories avoiding steam corrosion
  • Preparation of dry labware for microbiology

Key features

  • Forced-convection hot air at 160 to 180 degrees Celsius
  • Programmable ramp, hold and cooling cycles
  • Suitable for glassware, metal instruments and powders
  • No corrosion or residue from moisture
  • Biological indicator validation with Bacillus atrophaeus

Frequently asked questions about Dry Heat Sterilizer

Dry heat kills by oxidation and transfers heat slowly without the latent energy of condensing steam, so it needs higher temperature or longer time to reach the same lethality. Typical conditions are 160 degrees Celsius for two hours or 180 degrees Celsius for one hour.

Vertical Autoclave — product photo

Vertical Autoclave

立式高压灭菌器

  • CE (to be confirmed)
  • +2
Request a quote
Horizontal Autoclave — product photo

Horizontal Autoclave

卧式高压灭菌器

  • CE (to be confirmed)
  • +2
Request a quote

Request a quotation for the Dry Heat Sterilizer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote