Media Preparator and Sterilizer
培养基制备与灭菌器
- SKU STE-0004
- Sterilization Equipment
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Pressure vessel compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Working volume | 10–100 L |
|---|---|
| Sterilization temperature | 121 °C |
| Temperature range | 40–125 °C |
| Mixing | Motor-driven impeller, variable speed |
| Dispensing | Peristaltic pump with volume setting |
| Cooling | Automatic to pouring temperature |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 17665-1, EN 285, ISO 11138-1
What is the Media Preparator and Sterilizer?
A media preparator mixes, heats and sterilizes agar in one jacketed vessel and then dispenses it, reducing handling and improving consistency. It suits laboratories that prepare media in volume for routine plate pouring.
What is the Media Preparator and Sterilizer?
A media preparator mixes, heats and sterilizes agar in one jacketed vessel and then dispenses it, reducing handling and improving consistency. It suits laboratories that prepare media in volume for routine plate pouring.
Overview
A media preparator combines a jacketed stirred vessel, a heating and sterilization cycle and a dispensing system. Powder and water are mixed in the vessel, the medium is heated and sterilized in place at 121 degrees Celsius, then cooled to a pouring temperature under controlled agitation. Programmable cooling and automatic temperature holding let operators pour plates or dispense into bottles at the right temperature, and some units dose a fixed volume per plate. Because medium is not split into many bottles, batch-to-batch variation and handling steps are reduced, and the vessel is cleaned in place or easily dismantled. Volumes range from about 10 to 100 litres. The system suits food, water and clinical laboratories, and models with validated records are used in pharmaceutical and contract testing laboratories.
How does it work?
Moist-heat sterilization kills organisms by coagulating and denaturing proteins and nucleic acids in the presence of saturated steam. The decisive conditions are temperature, pressure and time: at 121 degrees Celsius and about 1 bar gauge a standard cycle holds for 15 to 20 minutes, while 134 degrees Celsius achieves quicker cycles typical of clinical waste. Steam must contact every surface, so the chamber is purged of air by gravity displacement in simple units or by repeated vacuum pulses in more advanced ones. Dry heat kills by oxidation and requires higher temperature or longer time, often 160 to 180 degrees Celsius for one to two hours. Media preparators combine mixing, heating and in-vessel sterilization so that agar is prepared and sterilized in one vessel rather than in bottles.
What are the key features?
- Jacketed stirred vessel for mixing, heating and sterilization
- In-vessel sterilization at 121 degrees Celsius
- Programmable cooling and pouring-temperature holding
- Volumetric dispensing for consistent plate volumes
- Clean-in-place or easily dismantled construction
What are the technical specifications?
A typical media preparator and sterilizer configuration offers working volume of 10–100 L, sterilization temperature of 121 °C, temperature range of 40–125 °C, mixing of Motor-driven impeller, variable speed, dispensing of Peristaltic pump with volume setting and cooling of Automatic to pouring temperature. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Media Preparator and Sterilizer is used in routine culture medium preparation, food and water microbiology, pharmaceutical media preparation and contract testing laboratories. Across the wider Sterilization Equipment class, laboratories also deploy it for sterilization of culture media and glassware, decontamination of microbiological waste and sterilization of instruments and labware.
Which standards and certifications apply?
Relevant standards and methods include ISO 17665-1, EN 285, ISO 11138-1, ISO 14937, ISO 7218 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Pressure vessel compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Operators must be trained in safe loading, correct cycle selection and the risks of hot liquids and pressurized steam. Load items so that steam circulates freely; do not overfill baskets, and loosen closures on bottles and containers. Verify each cycle with physical indicators and temperature records, and confirm performance periodically with biological indicators such as Geobacillus stearothermophilus spores. Drain and clean the chamber, check the door gasket and strainer, and descale the generator on a schedule. Record maintenance and requalification, including chamber temperature mapping. Ensure adequate ventilation and drainage, and confirm that the electrical installation meets the manufacturer's requirements and IEC 61010-1.
How do I select the right Media Preparator and Sterilizer?
Choose a media preparator when you prepare agar in volume and want consistent sterilization, cooling and dispensing. In an RFQ specify the working volume, sterilization temperature, cooling and holding capability, dispensing accuracy, cleaning method and record-keeping requirements.
How does it compare with other Sterilization Equipment variants?
Begin with the load and the required throughput. Small volumes of media, glassware and instruments suit a bench-top autoclave of 20 to 50 L, while a busy laboratory sterilizing large batches or waste may need a vertical or horizontal unit of 50 to 200 L or more. Confirm that the chamber size and basket arrangement fit your largest items and that the cycle type, gravity or pre-vacuum, removes air from porous loads and liquids. For media, a preparator reduces handling and improves consistency. Choose dry heat when steam would corrode instruments, wet powders or damage glassware. Check safety features such as door interlocks, pressure relief, overtemperature cut-out and cycle recording, and confirm that validation, biological indicators and service support are available.
Full specifications
| Working volume | 10–100 L |
|---|---|
| Sterilization temperature | 121 °C |
| Temperature range | 40–125 °C |
| Mixing | Motor-driven impeller, variable speed |
| Dispensing | Peristaltic pump with volume setting |
| Cooling | Automatic to pouring temperature |
| Vessel material | Stainless steel 316L |
| Control | PLC with recipe programs and logging |
| Power supply | 380 V three-phase |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine culture medium preparation
- Food and water microbiology
- Pharmaceutical media preparation
- Contract testing laboratories
Key features
- Jacketed stirred vessel for mixing, heating and sterilization
- In-vessel sterilization at 121 degrees Celsius
- Programmable cooling and pouring-temperature holding
- Volumetric dispensing for consistent plate volumes
- Clean-in-place or easily dismantled construction
Frequently asked questions about Media Preparator and Sterilizer
Medium is mixed and sterilized in one closed vessel and dispensed through a controlled path, so it is not poured between many bottles in open air. Fewer transfers mean fewer chances for contamination, and the receiving plates or bottles are filled quickly at the correct temperature.
Yes. Supplements such as antibiotics, blood or vitamins are added after the medium cools to a set temperature through an aseptic addition port, which avoids heat damage. The recipe program controls when the addition step occurs during the cycle.
Agar must be dispensed within a narrow temperature band, high enough not to set in the tubing and low enough not to damage supplements or produce excess condensation on plates. Programmable cooling and holding keep the medium in that band during long pouring runs.
It sterilizes culture media, glassware, instruments and waste so that only the intended organisms are present in a culture. Autoclaves use saturated steam, dry heat sterilizers use hot air, and media preparators sterilize agar in the vessel in which it is prepared.
Saturated steam at 121 degrees Celsius and about 1 bar gauge kills organisms quickly by denaturing their proteins, and a 15 to 20 minute hold gives a safety margin for typical loads. Higher temperatures such as 134 degrees Celsius shorten cycles but need better air removal.
A gravity cycle lets steam push air out through a drain, which is simple but leaves air pockets in porous or wrapped loads. A pre-vacuum cycle removes air with vacuum pulses before admitting steam, giving faster and more reliable penetration for such loads.