Microbiology Incubator
微生物培养箱
- SKU CUE-0001
- Culture Equipment
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient +5 to 70 °C |
|---|---|
| Temperature uniformity | ±0.5 °C |
| Temperature stability | ±0.2 °C |
| Chamber volume | 50–300 L |
| Shelves | 2–4 adjustable stainless shelves |
| Interior material | Stainless steel |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 7218, ISO 11133, ISO 17025
What is the Microbiology Incubator?
A microbiology incubator is a temperature-controlled cabinet for static culture of plates, slants and tubes. It provides even heat across shelves and is the basic incubation tool of clinical, food and pharmaceutical microbiology.
What is the Microbiology Incubator?
A microbiology incubator is a temperature-controlled cabinet for static culture of plates, slants and tubes. It provides even heat across shelves and is the basic incubation tool of clinical, food and pharmaceutical microbiology.
Overview
A microbiology incubator is a simple, reliable cabinet that holds cultures at a set temperature, typically 30 to 37 degrees Celsius. Heat is supplied by elements in an air jacket or by a water jacket, and a fan circulates air so that temperature is uniform from shelf to shelf, usually within half a degree. Models range from compact 50 L units to large cabinets of several hundred litres, with adjustable shelves, an inner glass door to reduce heat loss when the outer door opens, and a control system with overtemperature protection and alarms. Some cabinets offer programmable cycles for two temperatures or timed operation. Most are designed for dry incubation of plates and tubes; humidity and CO2 options are added when needed. Cleaning a smooth stainless-steel interior and avoiding overloaded shelves are the main practices that keep performance consistent.
How does it work?
Culture equipment holds a defined temperature and, where needed, provides motion that improves gas exchange. A microbiological incubator controls temperature with a thermostat or microprocessor driving heating elements, a water jacket or an air jacket, and a fan circulates air so that all shelves stay within a narrow range. A shaking incubator adds a motor-driven platform that moves in a circular orbit, increasing the surface area available for oxygen transfer and keeping broth cultures suspended, with speed set in revolutions per minute and amplitude in millimetres. Refrigerated models add a compressor or Peltier element for below-ambient temperatures used for psychrophiles and fungi. Roller apparatus rotates bottles about their long axis so adherent cells are alternately exposed to medium and gas, and spinner flask systems use a magnetic stir bar or impeller to keep suspension cells mixed.
What are the key features?
- Forced-air circulation for uniform shelf temperature
- Microprocessor control with overtemperature protection
- Inner glass door to limit heat loss when opened
- Adjustable shelves and optional stacked configurations
- Audible and visual alarms for temperature deviation
What are the technical specifications?
A typical microbiology incubator configuration offers temperature range of Ambient +5 to 70 °C, temperature uniformity of ±0.5 °C, temperature stability of ±0.2 °C, chamber volume of 50–300 L, shelves of 2–4 adjustable stainless shelves and interior material of Stainless steel. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Microbiology Incubator is used in clinical microbiology cultures, food and beverage microbiological testing, pharmaceutical bioburden testing and teaching laboratories. Across the wider Culture Equipment class, laboratories also deploy it for microbial culture in clinical and food laboratories, antibiotic and susceptibility testing and cell culture and scale-up studies.
Which standards and certifications apply?
Relevant standards and methods include ISO 7218, ISO 11133, ISO 17025, USP <1116> and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the unit on a level surface with clearance for ventilation, and let the chamber stabilize before use. Verify temperature with an independent calibrated probe at several shelf positions, because displayed values can differ from actual conditions. Do not overload shelves, as this blocks airflow and creates cold or hot spots. Clean and disinfect the chamber on a schedule, and handle spills promptly to prevent contamination. For shakers, check that flasks are clamped and balanced, and reduce speed if liquid climbs the flask wall. Record calibration and maintenance, review alarm logs, and confirm that any CO2 or humidity sensors are calibrated and their gas supply is stable. Electrical safety follows IEC 61010-1.
How do I select the right Microbiology Incubator?
Choose a microbiology incubator for static culture of plates and tubes where even, stable temperature matters more than motion. In an RFQ specify temperature range and uniformity, chamber volume, shelf loading, control and alarm features, and whether a glass door or stacked format is needed.
How does it compare with other Culture Equipment variants?
Choose the format from the culture method. Static plates and slants need a microbiological incubator with even temperature and adequate shelf space; broth cultures that demand oxygen need a shaking incubator, and the required speed, orbit diameter and shaking capacity should be matched to the flask sizes used. Add refrigeration when you work with psychrophiles, fungi or samples that must stay below room temperature. Roller culture apparatus suits scale-up of adherent cells in bottles, and spinner flask systems suit suspension or microcarrier culture. Confirm temperature range and uniformity, how fast the chamber recovers after door opening, chamber volume and shelf loading, alarm and data logging, and whether humidity or a CO2 option is needed. For regulated work, document calibration, mapping and verification success criteria.
Full specifications
| Temperature range | Ambient +5 to 70 °C |
|---|---|
| Temperature uniformity | ±0.5 °C |
| Temperature stability | ±0.2 °C |
| Chamber volume | 50–300 L |
| Shelves | 2–4 adjustable stainless shelves |
| Interior material | Stainless steel |
| Control | Microprocessor with timer and alarm |
| Power supply | 220–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Clinical microbiology cultures
- Food and beverage microbiological testing
- Pharmaceutical bioburden testing
- Teaching laboratories
Key features
- Forced-air circulation for uniform shelf temperature
- Microprocessor control with overtemperature protection
- Inner glass door to limit heat loss when opened
- Adjustable shelves and optional stacked configurations
- Audible and visual alarms for temperature deviation
Frequently asked questions about Microbiology Incubator
Clinical bacteria are usually incubated at 35 to 37 degrees Celsius, yeasts and moulds at 25 to 30 degrees Celsius, and some environmental or food organisms at 30 degrees Celsius or lower. The chosen temperature follows the method or compendial procedure in use.
The inner glass door lets operators view plates without exposing the whole chamber to room air. This shortens temperature recovery, protects other cultures from disturbance and reduces the risk of contamination from air movement when only a portion of the cabinet is opened.
Shelves should be loaded so that air can circulate freely, typically leaving gaps between stacks and keeping plates away from the walls and the fan. Overloading blocks airflow, produces hot and cold spots and lengthens recovery time after the door is opened.
It provides the temperature and motion conditions needed to grow microorganisms and cells, from static plate incubation to shaking broth culture and roller or spinner culture of cells. It supports clinical, food, environmental and pharmaceutical microbiological testing and research.
Use shaking when the culture needs oxygen or must stay suspended, such as broth cultures for growth curves, protein expression or susceptibility work. Static incubation suits plates, slants and samples where gentle conditions are sufficient and sedimentation is not a concern.
Refrigeration allows incubation below ambient temperature, which is required for psychrophilic organisms, many fungi and yeasts, and for sample holding at 20 to 25 degrees Celsius. It also lets the same cabinet serve as a controlled-temperature storage or enrichment unit.
Related models