MALDI-TOF Microbial Identification System
MALDI-TOF 微生物鉴定系统
- SKU MIO-0002
- Microbial Identification Systems
- CE-IVD (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 60825-1 laser classification (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Identification principle | MALDI-TOF mass spectrometry |
|---|---|
| Mass range | 2,000–20,000 Da |
| Laser | Nitrogen 337 nm or solid-state 355 nm |
| Target capacity | 96 spots (48 or 384 optional) |
| Time to result | 1–5 min per isolate |
| Database coverage | Several thousand species and subspecies |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI M35, CLSI M45, USP <1113>
What is the MALDI-TOF Microbial Identification System?
A MALDI-TOF microbial identification system measures ribosomal protein mass spectra from a colony and matches them to a reference database, giving species-level identification within minutes at a low reagent cost per sample.
What is the MALDI-TOF Microbial Identification System?
A MALDI-TOF microbial identification system measures ribosomal protein mass spectra from a colony and matches them to a reference database, giving species-level identification within minutes at a low reagent cost per sample.
Overview
A MALDI-TOF system prepares a thin film of a colony or extract on a target plate with a matrix, then fires a laser at each spot. Ionized ribosomal proteins travel through a time-of-flight tube, and the detector records a spectrum whose peak pattern is characteristic of a species. Software compares the spectrum with a curated library and reports the best matches with a score. Sample preparation is simple, results appear in minutes after the culture is available, and many instruments run 96 spots per plate. Performance depends on database coverage, culture quality and consistent target preparation and calibration. Isolates absent from the library, mixed cultures or those with unusual protein profiles give low scores and need a complementary method. Biosafety and target handling procedures matter because the process begins with live colonies.
How does it work?
Microbial identification systems match an unknown isolate to a reference database by measuring properties that are characteristic of a species. Biochemical systems inoculate miniaturized wells or cards with substrates such as sugars, amino acids and chromogenic compounds, and compare the resulting color or turbidity pattern with stored profiles. MALDI-TOF instruments ionize ribosomal proteins with a laser and align the mass spectrum with reference spectra. Molecular systems amplify conserved genes such as 16S rRNA, 23S rRNA or ITS regions with real-time PCR and compare melting profiles or sequences with databases. Immunological systems detect species-specific antigens with latex particles or labeled antibodies. Each method needs a current database, quality control strains and, for regulated use, documented validation.
What are the key features?
- Laser ionization with time-of-flight mass analysis
- 96-spot target plate for high throughput
- Simple colony film preparation
- Species-level identification in minutes
- Curated spectral database with score-based reporting
What are the technical specifications?
A typical maldi-tof microbial identification system configuration offers identification principle of MALDI-TOF mass spectrometry, mass range of 2,000–20,000 Da, laser of Nitrogen 337 nm or solid-state 355 nm, target capacity of 96 spots (48 or 384 optional), time to result of 1–5 min per isolate and database coverage of Several thousand species and subspecies. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The MALDI-TOF Microbial Identification System is used in clinical microbiology diagnostics, food and beverage microbiological testing, pharmaceutical environmental monitoring, veterinary diagnostics and research on microbial taxonomy. Across the wider Microbial Identification Systems class, laboratories also deploy it for clinical microbiology diagnostics, food and beverage microbiological testing and pharmaceutical environmental monitoring.
Which standards and certifications apply?
Relevant standards and methods include CLSI M35, CLSI M45, USP <1113>, ISO 7218, ISO 11133 and IEC 61010-1. Certification candidates for this model are CE-IVD, ISO 13485 manufacturing and IEC 60825-1 laser classification; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the reference database current, because outdated entries cause misidentification of emerging or renamed species. Run quality control strains on a defined schedule and record results. Follow the manufacturer's calibration for mass spectrometers and check tolerance with a standard. Handle cultures at the appropriate biosafety level, decontaminate instrument surfaces and manage waste. Validate new assays against a reference method before reporting, and define how conflicts between methods are resolved. For regulated laboratories, control software and database updates through change control and confirm audit-trail behaviour. Electrical safety follows IEC 61010-1 and laser instruments IEC 60825-1.
How do I select the right MALDI-TOF Microbial Identification System?
Choose MALDI-TOF when you need fast, low-cost identification of many cultivated isolates and can maintain the instrument and its database. In an RFQ specify mass range, target capacity, database scope and update policy, identification score thresholds, LIS interface and service requirements.
How does it compare with other Microbial Identification Systems variants?
Start with the organisms you identify and the level of discrimination you need. Biochemical panels are economical for routine clinical and food isolates and give species identification with additional susceptibility testing. MALDI-TOF offers fast, low reagent cost per sample but needs a substantial instrument and a well-maintained spectral database. Molecular methods are essential when organisms cannot be cultured, when identification must be rapid or when species-level discrimination of closely related taxa is required. Immunological systems are quick for confirming a suspected species. Consider throughput, turnaround time, database size and update policy, cost per test, training, biosafety level, and whether results must feed a laboratory information system with audit trails.
Full specifications
| Identification principle | MALDI-TOF mass spectrometry |
|---|---|
| Mass range | 2,000–20,000 Da |
| Laser | Nitrogen 337 nm or solid-state 355 nm |
| Target capacity | 96 spots (48 or 384 optional) |
| Time to result | 1–5 min per isolate |
| Database coverage | Several thousand species and subspecies |
| Sample preparation | Direct colony film or formic acid extraction |
| Calibration | Bacterial test standard, daily |
| Data output | LIS interface and spectrum archive |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Clinical microbiology diagnostics
- Food and beverage microbiological testing
- Pharmaceutical environmental monitoring
- Veterinary diagnostics
- Research on microbial taxonomy
Key features
- Laser ionization with time-of-flight mass analysis
- 96-spot target plate for high throughput
- Simple colony film preparation
- Species-level identification in minutes
- Curated spectral database with score-based reporting
Frequently asked questions about MALDI-TOF Microbial Identification System
Once a pure colony is available, preparation and measurement take only a few minutes per isolate, and a 96-spot plate can be completed in well under an hour. The overall time to result is therefore set mainly by the time needed to grow the organism.
Low scores occur when the species is absent from the database, when the culture is mixed or poorly grown, or when preparation and calibration vary. In those cases the laboratory repeats the preparation or uses a complementary method such as sequencing before reporting.
A bacterial test standard is measured daily to confirm mass accuracy and sensitivity, and a defined set of reference strains is identified at intervals to verify the database. Target plates and the ion source require cleaning, and the equipment log records calibration and QC results.
It identifies the genus and species of bacteria, yeasts or fungi from a pure culture or, with molecular methods, directly from a sample. Laboratories use it in clinical diagnostics, food and water safety testing, pharmaceutical environmental monitoring and bioprocess control.
For many cultivated bacteria and yeasts MALDI-TOF reaches species-level accuracy comparable to or better than biochemical panels, but performance depends on database coverage and on good quality spectra. Poor samples, mixed cultures or species absent from the database give low-confidence or incorrect results.
Molecular identification is preferred when an organism is difficult or slow to culture, when rapid results are needed, or when closely related species must be distinguished. Real-time PCR gives quick targeting of known pathogens, while 16S rRNA sequencing identifies unexpected organisms without prior assumptions.