Real-Time PCR Identification System
实时荧光 PCR 鉴定系统
- SKU MIO-0003
- Microbial Identification Systems
- CE-IVD (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Identification principle | Real-time PCR with fluorescent probes |
|---|---|
| Fluorescence channels | 4–6 channels |
| Thermal range | 4–99 °C |
| Temperature uniformity | ±0.3 °C |
| Heating and cooling rate | Up to 4 °C/s |
| Format | 96-well or 48-well, strip tubes |
By Lab Manufacturers China Technical TeamLast reviewed Standards: CLSI M35, CLSI M45, USP <1113>
What is the Real-Time PCR Identification System?
A real-time PCR identification system amplifies species-specific nucleic acid targets and detects them as the reaction proceeds, giving rapid identification of known pathogens directly from samples or cultures. It suits laboratories needing same-day answers
What is the Real-Time PCR Identification System?
A real-time PCR identification system amplifies species-specific nucleic acid targets and detects them as the reaction proceeds, giving rapid identification of known pathogens directly from samples or cultures. It suits laboratories needing same-day answers
Overview
A real-time PCR identification system extracts nucleic acid from a sample or colony, mixes it with primers, probes and master mix, and runs a thermal cycle while monitoring fluorescence. When the target sequence is present, the probe releases signal each cycle, and the instrument records the cycle threshold. Multiplex panels detect several organisms or markers in one tube using different fluorophores, and some assays include an internal amplification control to flag inhibition. Because the target is amplified, detection is sensitive and can proceed directly from enriched or primary samples without full culture. Identification is limited to the organisms covered by the chosen primers, so panel selection and confirmation of unexpected results by culture or sequencing remain important. Contamination control and unidirectional workflow are essential in molecular laboratories.
How does it work?
Microbial identification systems match an unknown isolate to a reference database by measuring properties that are characteristic of a species. Biochemical systems inoculate miniaturized wells or cards with substrates such as sugars, amino acids and chromogenic compounds, and compare the resulting color or turbidity pattern with stored profiles. MALDI-TOF instruments ionize ribosomal proteins with a laser and align the mass spectrum with reference spectra. Molecular systems amplify conserved genes such as 16S rRNA, 23S rRNA or ITS regions with real-time PCR and compare melting profiles or sequences with databases. Immunological systems detect species-specific antigens with latex particles or labeled antibodies. Each method needs a current database, quality control strains and, for regulated use, documented validation.
What are the key features?
- Amplifies species-specific targets with probe-based detection
- Multiplex panels detect several organisms per tube
- Internal amplification control flags inhibition
- Direct testing from enriched or primary samples
- Cycle threshold reporting with automated interpretation
What are the technical specifications?
A typical real-time pcr identification system configuration offers identification principle of Real-time PCR with fluorescent probes, fluorescence channels of 4–6 channels, thermal range of 4–99 °C, temperature uniformity of ±0.3 °C, heating and cooling rate of Up to 4 °C/s and format of 96-well or 48-well, strip tubes. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Real-Time PCR Identification System is used in rapid clinical pathogen identification, food pathogen detection, water quality monitoring, pharmaceutical environmental monitoring and veterinary diagnostics. Across the wider Microbial Identification Systems class, laboratories also deploy it for clinical microbiology diagnostics, food and beverage microbiological testing and pharmaceutical environmental monitoring.
Which standards and certifications apply?
Relevant standards and methods include CLSI M35, CLSI M45, USP <1113>, ISO 7218, ISO 11133 and IEC 61010-1. Certification candidates for this model are CE-IVD, ISO 13485 manufacturing and IEC 61010-1 compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the reference database current, because outdated entries cause misidentification of emerging or renamed species. Run quality control strains on a defined schedule and record results. Follow the manufacturer's calibration for mass spectrometers and check tolerance with a standard. Handle cultures at the appropriate biosafety level, decontaminate instrument surfaces and manage waste. Validate new assays against a reference method before reporting, and define how conflicts between methods are resolved. For regulated laboratories, control software and database updates through change control and confirm audit-trail behaviour. Electrical safety follows IEC 61010-1 and laser instruments IEC 60825-1.
How do I select the right Real-Time PCR Identification System?
Choose real-time PCR when you need fast identification of known organisms, direct testing from enriched samples or multiplex detection. In an RFQ specify fluorescence channels, plate format, thermal performance, validated target panels, extraction compatibility, software reporting and contamination-control design.
How does it compare with other Microbial Identification Systems variants?
Start with the organisms you identify and the level of discrimination you need. Biochemical panels are economical for routine clinical and food isolates and give species identification with additional susceptibility testing. MALDI-TOF offers fast, low reagent cost per sample but needs a substantial instrument and a well-maintained spectral database. Molecular methods are essential when organisms cannot be cultured, when identification must be rapid or when species-level discrimination of closely related taxa is required. Immunological systems are quick for confirming a suspected species. Consider throughput, turnaround time, database size and update policy, cost per test, training, biosafety level, and whether results must feed a laboratory information system with audit trails.
Full specifications
| Identification principle | Real-time PCR with fluorescent probes |
|---|---|
| Fluorescence channels | 4–6 channels |
| Thermal range | 4–99 °C |
| Temperature uniformity | ±0.3 °C |
| Heating and cooling rate | Up to 4 °C/s |
| Format | 96-well or 48-well, strip tubes |
| Time to result | 1–2 h including extraction |
| Sensitivity | Down to 10–100 copies per reaction |
| Data output | Amplification curves, Ct values, LIS export |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Rapid clinical pathogen identification
- Food pathogen detection
- Water quality monitoring
- Pharmaceutical environmental monitoring
- Veterinary diagnostics
Key features
- Amplifies species-specific targets with probe-based detection
- Multiplex panels detect several organisms per tube
- Internal amplification control flags inhibition
- Direct testing from enriched or primary samples
- Cycle threshold reporting with automated interpretation
Frequently asked questions about Real-Time PCR Identification System
It reports whether a specific nucleic acid target was amplified, indicated by the cycle threshold at which fluorescence rises. A low cycle threshold suggests more target. Results are qualitative for presence or absence, though some assays are validated for quantification.
No. It detects only the targets covered by the primers and probes in the panel, so organisms outside the panel are not seen. Unknown or unexpected isolates still need culture, mass spectrometry or sequencing, and panels may need updating as new variants emerge.
Amplified products are a potent contamination source, and a single carried-over amplicon can cause false positives. Laboratories separate extraction, reagent preparation and amplification areas, use uracil-N-glycosylase where appropriate, include negative controls and monitor results to detect contamination early.
It identifies the genus and species of bacteria, yeasts or fungi from a pure culture or, with molecular methods, directly from a sample. Laboratories use it in clinical diagnostics, food and water safety testing, pharmaceutical environmental monitoring and bioprocess control.
For many cultivated bacteria and yeasts MALDI-TOF reaches species-level accuracy comparable to or better than biochemical panels, but performance depends on database coverage and on good quality spectra. Poor samples, mixed cultures or species absent from the database give low-confidence or incorrect results.
Molecular identification is preferred when an organism is difficult or slow to culture, when rapid results are needed, or when closely related species must be distinguished. Real-time PCR gives quick targeting of known pathogens, while 16S rRNA sequencing identifies unexpected organisms without prior assumptions.