Capacitance Seed Moisture Meter
电容式种子水分仪
- SKU SMM-0001
- Seed Moisture Meters
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Capacitance (dielectric constant) |
|---|---|
| Moisture range | 5–40%, species dependent |
| Accuracy | ±0.5% vs oven method |
| Repeatability | ±0.1% |
| Measurement time | 3–10 s |
| Sample volume | 100–500 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISTA Rules Chapter 9 (moisture), ISO 712 (cereals moisture), ISO 6540 (maize moisture)
What is the Capacitance Seed Moisture Meter?
A meter that reads seed moisture from the dielectric constant of a fixed sample volume. It is the right choice for fast, routine checks of grain and seed lots at intake, in stores and during drying.
What is the Capacitance Seed Moisture Meter?
A meter that reads seed moisture from the dielectric constant of a fixed sample volume. It is the right choice for fast, routine checks of grain and seed lots at intake, in stores and during drying.
Overview
The capacitance moisture meter fills a measuring cell or cup with a fixed volume of seed and measures the dielectric constant of the sample at a known frequency. Because water has a much higher dielectric constant than dry matter, the reading rises sharply with moisture content, and stored calibrations for each species and often variety group convert the signal to a moisture percentage. Temperature strongly affects the reading, so a built-in sensor applies compensation, and some instruments also weigh the sample to compute test weight. Handheld and benchtop models cover a moisture range of about 5 to 40 percent depending on the species. The meter is calibrated against the oven reference method and verified with a reference sample or resistor. Fast operation makes it ideal for many daily checks, but the readings are relative and can be biased by seed shape, variety and fill volume, so calibration and consistent procedure are essential.
How does it work?
Moisture meters exploit the difference between water and dry matter. Capacitance meters place a fixed volume of seed in an electric field and measure the dielectric constant, which rises strongly with water content, converting the value to moisture percentage through a calibration specific to species, variety and temperature. Near-infrared meters measure reflectance or transmission and predict moisture from spectra, again using species-specific models. Loss-on-drying analyzers, using halogen, infrared or microwave heating, weigh the sample, dry it until the mass is stable and calculate the water driven off, which is the reference approach. Results may be expressed on a wet basis, the water fraction of the fresh sample, or a dry basis, which is needed for some standards. Equilibrium between the seed and the surrounding air means samples must be sealed and analysed quickly.
What are the key features?
- Fast reading from a fixed-volume seed sample.
- Species-specific calibrations cover cereals, pulses and oilseeds.
- Automatic temperature compensation reduces seasonal error.
- Optional weighing adds test weight or bulk density.
- Internal memory averages and stores many readings.
- Reference sample or resistor verifies calibration.
What are the technical specifications?
A typical capacitance seed moisture meter configuration offers measurement principle of Capacitance (dielectric constant), moisture range of 5–40%, species dependent, accuracy of ±0.5% vs oven method, repeatability of ±0.1%, measurement time of 3–10 s and sample volume of 100–500 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Capacitance Seed Moisture Meter is used in seed intake moisture checks, storage safety monitoring, drying and conditioning control and trade settlement measurements. Across the wider Seed Moisture Meters class, laboratories also deploy it for seed lot storage safety assessment, trade contract moisture compliance and drying and conditioning control.
Which standards and certifications apply?
Relevant standards and methods include ISTA Rules Chapter 9 (moisture), ISO 712 (cereals moisture), ISO 6540 (maize moisture), AACC Method 44-15A and GB/T 3543.6 (seed moisture). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Seal samples in moisture-tight containers immediately after sampling and analyse within the time the method allows, because seeds exchange water with ambient air. Fill capacitance meters to the correct volume, use the species calibration and record the sample temperature. For oven methods, control temperature, time and grinding exactly as specified, and cool samples in a desiccator before weighing to the required resolution. Verify meters against the oven method for each species and season, and keep a reference sample for checks. Avoid measuring seed that has been in a warm room for a long time without equilibration, since surface drying gives a low reading. Record species, variety, calibration used and result basis, and maintain the instrument's temperature sensor and balance on a calibration schedule.
How do I select the right Capacitance Seed Moisture Meter?
Select the capacitance meter for rapid routine checks where a calibration exists for the species and results are verified against the oven method. For reference reporting, use the prescribed oven procedure. In an RFQ, specify species, moisture range, accuracy and whether test weight is needed.
How does it compare with other Seed Moisture Meters variants?
Select the method according to the standard and the required accuracy. When a result must be reported under ISTA, national seed rules or a contract, use the oven procedure specified in the method, and use a meter only for screening or process control. For rapid checks on many lots, choose a capacitance or near-infrared instrument with a calibration for the exact species and variety group, and verify it against the oven method. Nominal capacitance readings are strongly affected by temperature and fill volume, so temperature compensation and consistent sample filling are essential. Near-infrared instruments need representative, clean samples and periodic bias adjustment. For oily seeds, small seeds and coated seed, confirm that a calibration exists. Consider portability, data export and sample throughput when many lots are checked daily.
Full specifications
| Measurement principle | Capacitance (dielectric constant) |
|---|---|
| Moisture range | 5–40%, species dependent |
| Accuracy | ±0.5% vs oven method |
| Repeatability | ±0.1% |
| Measurement time | 3–10 s |
| Sample volume | 100–500 mL |
| Temperature compensation | 0–40 °C, automatic |
| Species calibrations | Wheat, rice, maize, barley, soybean |
| Data memory | Up to 1000 records |
| Power supply | Battery or mains |
| Operating temperature | 0–40 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Seed intake moisture checks
- Storage safety monitoring
- Drying and conditioning control
- Trade settlement measurements
Key features
- Fast reading from a fixed-volume seed sample.
- Species-specific calibrations cover cereals, pulses and oilseeds.
- Automatic temperature compensation reduces seasonal error.
- Optional weighing adds test weight or bulk density.
- Internal memory averages and stores many readings.
- Reference sample or resistor verifies calibration.
Frequently asked questions about Capacitance Seed Moisture Meter
The dielectric constant of water and of the seed matrix changes with temperature, so a warm sample reads higher than a cool one at the same moisture. Built-in temperature sensors compensate the reading to a reference temperature.
Fill the cup completely and level it consistently, because the dielectric field depends on the sample volume between the electrodes. Under- or over-filling is a common source of error, so the procedure should be followed exactly.
No. Seed size, shape, density and coat structure differ between varieties and change the dielectric response, so calibrations are grouped by species and, where available, by variety type. Verification against the oven method confirms suitability.
Wet basis expresses water as a percentage of the fresh sample mass, while dry basis expresses it as a percentage of the dry matter. Trade and most seed rules use wet basis, but some standards and research report dry basis, so the basis must always be stated.
Seeds continuously exchange water with the air and reach an equilibrium with ambient humidity. If a sample is left open, it gains or loses water, so the measured value no longer represents the lot at sampling. Sealed analysis within the allowed time avoids this error.
Compare it with the oven reference method for each species, using samples spanning the working moisture range, and calculate the average bias and scatter. Repeat the check each season and after repair or calibration changes, adjusting the meter if bias exceeds tolerance.
Related models