

TDLAS In-Situ Gas Analyzer
可调谐激光原位气体分析仪
- SKU SGA-0005
- Stack Gas Analyzers
- CE (to be confirmed)
- China environmental monitoring instrument certification (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Tunable diode laser absorption spectroscopy |
|---|---|
| Target gases | NH3, HCl, H2O, O2, CO, optional others |
| Lower detection limit | < 0.5 ppm (NH3, HCl) |
| Response time | 1–2 s |
| Path length | 0.5–10 m (stack width) |
| Maximum gas temperature | Up to 800 °C (probe dependent) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14181, ISO 16911-1, ISO 12039
What is the TDLAS In-Situ Gas Analyzer?
A laser spectrometer that measures specific gases across the stack without extracting a sample. It is the right choice for fast, low-interference measurement of ammonia, hydrogen chloride, moisture and oxygen in difficult flue gas.
What is the TDLAS In-Situ Gas Analyzer?
A laser spectrometer that measures specific gases across the stack without extracting a sample. It is the right choice for fast, low-interference measurement of ammonia, hydrogen chloride, moisture and oxygen in difficult flue gas.
Overview
The TDLAS analyzer projects a near-infrared laser beam across the duct to a detector on the opposite side, scanning the wavelength across a single absorption line of the target gas. Because the measurement is made in situ over the full duct width, it gives a path-averaged concentration that represents the whole cross-section and responds in about one second. The narrow linewidth avoids the interference that broad-band methods suffer from, so ammonia, hydrogen chloride, moisture and oxygen can be measured in hot, wet, dusty gas with minimal conditioning. Wavelength modulation and second-harmonic detection improve the signal-to-noise ratio and allow low detection limits. Alignment, window cleanliness and temperature and pressure compensation are the main operating requirements, and an in-situ probe or a cross-stack pair can be used. The technique supports ammonia slip control in DeNOx systems and moisture correction for other analyzers.
How does it work?
Stack gas analyzers combine gas extraction or in-situ probes with one or more detection techniques. Electrochemical cells and zirconia sensors measure oxygen and select gases in portable instruments, while non-dispersive infrared detectors quantify carbon monoxide, carbon dioxide and sulfur dioxide by absorption at characteristic wavelengths. Chemiluminescence or ultraviolet absorption is used for nitrogen oxides. Fourier transform infrared analyzers resolve many gases at once from a single spectrum, including hydrogen chloride, ammonia and moisture. Tunable diode laser analyzers scan a narrow absorption line in situ and give fast, interference-resistant readings of species such as ammonia or hydrogen chloride. A heated sample line and conditioning system remove water and dust so the composition reaching the detector represents the stack. Flow monitors, temperature probes and data acquisition complete a continuous emission monitoring system.
What are the key features?
- In-situ cross-stack measurement gives one-second, path-averaged results.
- Narrow laser line avoids interference from overlapping gas absorptions.
- Measures NH3, HCl, H2O and O2 in hot, wet, dusty gas.
- Wavelength modulation detects low concentrations with high signal-to-noise.
- No sample extraction means no heated line or conditioning losses.
- Supports ammonia slip control and moisture correction.
What are the technical specifications?
A typical tdlas in-situ gas analyzer configuration offers measurement principle of Tunable diode laser absorption spectroscopy, target gases of NH3, HCl, H2O, O2, CO, optional others, lower detection limit of < 0.5 ppm (NH3, HCl), response time of 1–2 s, path length of 0.5–10 m (stack width) and maximum gas temperature of Up to 800 °C (probe dependent). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The TDLAS In-Situ Gas Analyzer is used in deNOx ammonia slip monitoring, waste incineration HCl control, moisture measurement for CEMS correction and cement and glass kiln gas analysis. Across the wider Stack Gas Analyzers class, laboratories also deploy it for power plant continuous emission monitoring, cement and steel plant flue gas analysis and waste incineration emission control.
Which standards and certifications apply?
Relevant standards and methods include EN 14181, ISO 16911-1, ISO 12039, US EPA 40 CFR Part 60 Appendix B, HJ 75 and GB 13223. Certification candidates for this model are CE, China environmental monitoring instrument certification and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Locate the sampling point where the gas is well mixed and within the acceptable temperature range, and keep the heated line above the acid dew point to prevent sulfur trioxide and water condensation. Calibrate with certified standards and check linearity, and run zero and span checks on the schedule required by the quality assurance standard. For continuous systems, annual surveillance audits and periodic reference method comparisons are commonly required. Replace filters, dryer components and pump parts regularly, and verify flow and temperature sensors. Protect optics and sensors from dust and corrosion, and record all calibration and maintenance events. Document the measurement uncertainty and apply the applicable quality assurance levels for reporting.
How do I select the right TDLAS In-Situ Gas Analyzer?
Select TDLAS for fast, low-interference measurement of specific gases, particularly ammonia and hydrogen chloride, in difficult flue gas. For a broad multi-gas suite, FTIR or NDIR is more economical. In an RFQ, specify the gas, detection limit, stack width and temperature and the window purge arrangements.
How does it compare with other Stack Gas Analyzers variants?
Choose by purpose: portable analyzers for combustion tuning and periodic checks, fixed systems for continuous emission compliance. Define the gas list and the ranges: oxygen typically 0 to 25 percent, carbon monoxide 0 to 1000 ppm, sulfur dioxide 0 to 500 ppm and nitrogen oxides 0 to 500 ppm for many combustion sources, with wider ranges for waste incineration and cement kilns. Select the extraction or in-situ format according to the need for fast response, the corrosiveness of the gas and the number of components. For multi-component compliance, NDIR plus chemiluminescence or FTIR systems are standard; for specific acidic or reactive species, TDLAS offers low interference. Confirm heated sampling, dust and moisture removal, calibration gas arrangements and conformity with the applicable method.
Full specifications
| Measurement principle | Tunable diode laser absorption spectroscopy |
|---|---|
| Target gases | NH3, HCl, H2O, O2, CO, optional others |
| Lower detection limit | < 0.5 ppm (NH3, HCl) |
| Response time | 1–2 s |
| Path length | 0.5–10 m (stack width) |
| Maximum gas temperature | Up to 800 °C (probe dependent) |
| Measurement zone | In-situ cross-stack or probe |
| Compensation | Temperature and pressure, internal |
| Outputs | 4–20 mA, Modbus, Ethernet |
| Power supply | 220 VAC, 50 Hz |
| Purge air | Clean, dry instrument air for windows |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- DeNOx ammonia slip monitoring
- Waste incineration HCl control
- Moisture measurement for CEMS correction
- Cement and glass kiln gas analysis
Key features
- In-situ cross-stack measurement gives one-second, path-averaged results.
- Narrow laser line avoids interference from overlapping gas absorptions.
- Measures NH3, HCl, H2O and O2 in hot, wet, dusty gas.
- Wavelength modulation detects low concentrations with high signal-to-noise.
- No sample extraction means no heated line or conditioning losses.
- Supports ammonia slip control and moisture correction.
Frequently asked questions about TDLAS In-Situ Gas Analyzer
Ammonia is sticky and water-soluble, so it is easily lost in extractive sampling lines and coolers. Measuring in situ across the duct avoids contact with cold surfaces, giving a more accurate ammonia slip value for DeNOx control.
Window cleanliness is the main issue, so clean, dry purge air is supplied continuously and windows are inspected and cleaned periodically. Alignment is checked after any duct work, and the laser module may need replacement after several years.
High dust loading attenuates the beam and reduces signal, so the technique works best in moderate dust or with a short measurement path. Some installations use a probe that protrudes into the duct to shorten the path and avoid the most heavily loaded regions.
Common targets are oxygen, carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen oxides and total hydrocarbons, with hydrogen chloride, ammonia, mercury and moisture added for waste incineration and specific processes. The list follows the emission standard that applies to the plant.
Water vapour and sulfur trioxide in flue gas can condense in cool tubing, dissolving water-soluble gases such as sulfur dioxide and hydrogen chloride and causing low readings. Heating the line above the acid dew point, typically 120 to 180 °C, keeps the sample in the vapour phase.
Extraction systems pull gas through a heated line to a conditioning unit and analyzer, allowing the removal of dust and moisture and the measurement of many components. In-situ analyzers measure across the stack directly, giving fast response with less conditioning but more sensitivity to dust loading and alignment.
Related models






