Portable Flue Gas Analyzer
便携式烟气分析仪
- SKU SGA-0001
- Stack Gas Analyzers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measured gases | O2, CO, NO, NO2, SO2, optional CO2 |
|---|---|
| Oxygen range | 0–25% |
| Carbon monoxide range | 0–10,000 ppm (dual range) |
| Nitrogen oxides range | 0–5000 ppm |
| Sulfur dioxide range | 0–5000 ppm |
| Flue temperature | 0–1200 °C (thermocouple type) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: EN 14181, ISO 16911-1, ISO 12039
What is the Portable Flue Gas Analyzer?
A handheld battery analyzer with electrochemical and infrared sensors for combustion tuning and periodic emissions checks. It is the right choice for boiler adjustment, burner service and short-term stack testing at multiple sites.
What is the Portable Flue Gas Analyzer?
A handheld battery analyzer with electrochemical and infrared sensors for combustion tuning and periodic emissions checks. It is the right choice for boiler adjustment, burner service and short-term stack testing at multiple sites.
Overview
The portable flue gas analyzer combines a sampling probe, a condensate trap, a pump and a set of plug-in sensors in a hand-held unit. Electrochemical cells measure oxygen, carbon monoxide, nitric oxide, nitrogen dioxide and sulfur dioxide, while an optional infrared bench covers carbon dioxide and higher carbon monoxide ranges. A thermocouple in the probe reads flue temperature, and the instrument computes combustion efficiency, excess air and reference-oxygen corrected values. Ranges and sensor combinations are chosen for the fuels to be tested, from natural gas boilers to diesel engines and coal stoves. Data logging, Bluetooth printing and internal memory make it easy to document burner settings after service. Response is a few seconds to a minute, and sensors are user-replaceable when depleted. The analyzer is typically warmed in clean air and calibrated with a known gas before each campaign.
How does it work?
Stack gas analyzers combine gas extraction or in-situ probes with one or more detection techniques. Electrochemical cells and zirconia sensors measure oxygen and select gases in portable instruments, while non-dispersive infrared detectors quantify carbon monoxide, carbon dioxide and sulfur dioxide by absorption at characteristic wavelengths. Chemiluminescence or ultraviolet absorption is used for nitrogen oxides. Fourier transform infrared analyzers resolve many gases at once from a single spectrum, including hydrogen chloride, ammonia and moisture. Tunable diode laser analyzers scan a narrow absorption line in situ and give fast, interference-resistant readings of species such as ammonia or hydrogen chloride. A heated sample line and conditioning system remove water and dust so the composition reaching the detector represents the stack. Flow monitors, temperature probes and data acquisition complete a continuous emission monitoring system.
What are the key features?
- Plug-in electrochemical and infrared sensors cover common combustion gases.
- Integrated flue temperature probe supports efficiency and excess air calculations.
- Condensate trap and pump protect sensors from water and dust.
- Internal memory and Bluetooth printing document burner settings.
- Battery operation suits work at multiple sites without mains power.
- User-replaceable sensors keep long-term running costs predictable.
What are the technical specifications?
A typical portable flue gas analyzer configuration offers measured gases of O2, CO, NO, NO2, SO2, optional CO2, oxygen range of 0–25%, carbon monoxide range of 0–10,000 ppm (dual range), nitrogen oxides range of 0–5000 ppm, sulfur dioxide range of 0–5000 ppm and flue temperature of 0–1200 °C (thermocouple type). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Portable Flue Gas Analyzer is used in boiler and burner commissioning, service and maintenance combustion tuning, short-term emission surveys and biomass and coal stove performance checks. Across the wider Stack Gas Analyzers class, laboratories also deploy it for power plant continuous emission monitoring, cement and steel plant flue gas analysis and waste incineration emission control.
Which standards and certifications apply?
Relevant standards and methods include EN 14181, ISO 16911-1, ISO 12039, US EPA 40 CFR Part 60 Appendix B, HJ 75 and GB 13223. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Locate the sampling point where the gas is well mixed and within the acceptable temperature range, and keep the heated line above the acid dew point to prevent sulfur trioxide and water condensation. Calibrate with certified standards and check linearity, and run zero and span checks on the schedule required by the quality assurance standard. For continuous systems, annual surveillance audits and periodic reference method comparisons are commonly required. Replace filters, dryer components and pump parts regularly, and verify flow and temperature sensors. Protect optics and sensors from dust and corrosion, and record all calibration and maintenance events. Document the measurement uncertainty and apply the applicable quality assurance levels for reporting.
How do I select the right Portable Flue Gas Analyzer?
Select the portable analyzer for tuning and periodic checks where a fixed CEMS is unnecessary. When continuous compliance data is required, a fixed extraction or in-situ system is needed. In an RFQ, state the fuels, gas list, ranges, probe length and whether reference-oxygen calculations and reporting software are needed.
How does it compare with other Stack Gas Analyzers variants?
Choose by purpose: portable analyzers for combustion tuning and periodic checks, fixed systems for continuous emission compliance. Define the gas list and the ranges: oxygen typically 0 to 25 percent, carbon monoxide 0 to 1000 ppm, sulfur dioxide 0 to 500 ppm and nitrogen oxides 0 to 500 ppm for many combustion sources, with wider ranges for waste incineration and cement kilns. Select the extraction or in-situ format according to the need for fast response, the corrosiveness of the gas and the number of components. For multi-component compliance, NDIR plus chemiluminescence or FTIR systems are standard; for specific acidic or reactive species, TDLAS offers low interference. Confirm heated sampling, dust and moisture removal, calibration gas arrangements and conformity with the applicable method.
Full specifications
| Measured gases | O2, CO, NO, NO2, SO2, optional CO2 |
|---|---|
| Oxygen range | 0–25% |
| Carbon monoxide range | 0–10,000 ppm (dual range) |
| Nitrogen oxides range | 0–5000 ppm |
| Sulfur dioxide range | 0–5000 ppm |
| Flue temperature | 0–1200 °C (thermocouple type) |
| Response time | 30–60 s typical |
| Data memory | Up to 2000 records |
| Battery life | 8–12 h |
| Probe length | 300 mm standard, 1000 mm optional |
| Operating temperature | −5 to 45 °C |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Boiler and burner commissioning
- Service and maintenance combustion tuning
- Short-term emission surveys
- Biomass and coal stove performance checks
Key features
- Plug-in electrochemical and infrared sensors cover common combustion gases.
- Integrated flue temperature probe supports efficiency and excess air calculations.
- Condensate trap and pump protect sensors from water and dust.
- Internal memory and Bluetooth printing document burner settings.
- Battery operation suits work at multiple sites without mains power.
- User-replaceable sensors keep long-term running costs predictable.
Frequently asked questions about Portable Flue Gas Analyzer
Electrochemical oxygen cells last about two years, while carbon monoxide and nitrogen oxide cells typically last one to two years depending on exposure. Replacement is indicated when span response falls below about 80 percent of the original value.
Emission limits are written at a fixed oxygen concentration, such as 3 or 6 percent, so the measured pollutant value is recalculated by a formula that accounts for the measured oxygen. Without correction, dilution by excess air would artificially lower the reported concentration.
Change or dry the condensate trap, replace particulate filters, check the probe for soot and periodically verify calibration with a known gas. Sensors, the pump and the battery are the main consumables and are replaced as performance declines.
Common targets are oxygen, carbon monoxide, carbon dioxide, sulfur dioxide, nitrogen oxides and total hydrocarbons, with hydrogen chloride, ammonia, mercury and moisture added for waste incineration and specific processes. The list follows the emission standard that applies to the plant.
Water vapour and sulfur trioxide in flue gas can condense in cool tubing, dissolving water-soluble gases such as sulfur dioxide and hydrogen chloride and causing low readings. Heating the line above the acid dew point, typically 120 to 180 °C, keeps the sample in the vapour phase.
Extraction systems pull gas through a heated line to a conditioning unit and analyzer, allowing the removal of dust and moisture and the measurement of many components. In-situ analyzers measure across the stack directly, giving fast response with less conditioning but more sensitivity to dust loading and alignment.