

Semi-Automatic Biochemistry Analyzer with Open Reagent Channels
开放试剂通道半自动生化分析仪
- SKU SEM-0002
- Semi-Automatic Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA registration for the analyzer (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Wavelength selection | 340–800 nm, 7 filters or monochromator |
|---|---|
| Assay programs | Up to 200 user-defined programs |
| Sample volume | 5–50 µL programmable |
| Reagent volume | 200–1000 µL programmable |
| Calibration | Factor, one-point and multi-point from stored calibrators |
| Temperature control | 25, 30 and 37 °C selectable |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP06
What is the Semi-Automatic Biochemistry Analyzer with Open Reagent Channels?
This variant is programmed for user-defined assays so that the laboratory can run third-party reagents, giving flexibility and low reagent cost. It suits clinics with an established menu that buy reagents locally and validate each assay themselves.
What is the Semi-Automatic Biochemistry Analyzer with Open Reagent Channels?
This variant is programmed for user-defined assays so that the laboratory can run third-party reagents, giving flexibility and low reagent cost. It suits clinics with an established menu that buy reagents locally and validate each assay themselves.
Overview
The instrument provides open programming: the operator enters wavelength, sample and reagent volumes, incubation time, reading window and calculation method, then stores the protocol under a test code. Calibration is performed with the calibrator supplied with the third-party kit, and the resulting factor or curve is stored and used until it is replaced. This approach lets the laboratory use reagents from several suppliers and adapt to new assays without a proprietary kit, but it also makes the laboratory responsible for method validation, including linearity, precision and reference interval checks. Practical features that support open use include a wide filter set or monochromator, adjustable reading intervals, flexible units of concentration and the ability to print a full reaction record for documentation.
How does it work?
A semi-automatic analyzer contains a light source, a wavelength selector such as interference filters or a grating, a temperature-controlled measuring position and a photodetector. The operator pipettes a measured volume of sample and working reagent into a cuvette or into a flow-through cell, mixes, and starts the reading. The instrument records absorbance at one or more wavelengths at fixed intervals, applies endpoint, kinetic or fixed-time calculation according to the selected program, and converts the signal into concentration using a stored calibration curve. Because the reaction temperature strongly affects enzyme kinetics, the measuring position is held at 37 degrees Celsius or at another programmed temperature, usually within 0.1 degrees Celsius. The operator's pipetting technique, cuvette cleanliness and correct reagent preparation determine the quality of the result, which is why training and written procedures matter more on this platform than on a fully automatic analyzer.
What are the key features?
- User-programmable assay parameters stored under test codes
- Open reagent compatibility with third-party kits
- Adjustable reading intervals and calculation windows
- Wide filter set or monochromator for method flexibility
- Configurable concentration units and print formats
- Reaction curve printout for method documentation
What are the technical specifications?
A typical semi-automatic biochemistry analyzer with open reagent channels configuration offers wavelength selection of 340–800 nm, 7 filters or monochromator, assay programs of Up to 200 user-defined programs, sample volume of 5–50 µL programmable, reagent volume of 200–1000 µL programmable, calibration of Factor, one-point and multi-point from stored calibrators and temperature control of 25, 30 and 37 °C selectable. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Semi-Automatic Biochemistry Analyzer with Open Reagent Channels is used in clinics using locally sourced reagents, assays not available as proprietary kits, veterinary and agricultural biochemistry and custom methods in research laboratories. Across the wider Semi-Automatic Analyzers class, laboratories also deploy it for low-volume clinical chemistry testing, rural and outreach clinics and veterinary biochemistry.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP06, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA registration for the analyzer; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a level bench away from draughts, direct sunlight and vibration, with a stable power supply and a grounded outlet. Verify performance at installation with a reference material or an assigned sample, and check the temperature of the measuring position with an external thermometer. Daily work should include a distilled water blank, a control sample at normal and abnormal levels, and cleaning of the flow cell or cuvette holder. Replace lamps at the end of their rated life or when the blank absorbance rises, keep filters clean and dry, and store reagents according to the label. The laboratory must document operator competence, since results depend on pipetting accuracy, and should review calibration at each new reagent lot.
How do I select the right Semi-Automatic Biochemistry Analyzer with Open Reagent Channels?
Choose open programming when reagent supply flexibility and cost per test dominate the decision, and when the laboratory has the technical capacity to validate methods. In the RFQ confirm which parameters can be edited, whether wavelength selection is continuous, and whether the software supports two-point calibration with a blank. Ask for the programming manual so that your staff can judge how easily new methods can be entered.
How does it compare with other Semi-Automatic Analyzers variants?
Choose a semi-automatic analyzer when the budget is limited, when fewer than about one hundred tests are performed per day, or when the reagent menu changes often and single-channel flexibility is valuable. Compare models by the wavelength range and filter set, whether they use a flow-through cell or single cuvettes, the temperature control accuracy, and the calculation modes supported. A flow-through cell reduces cuvette cost but needs careful cleaning between samples to avoid carryover, while disposable cuvettes simplify workflow at higher consumable cost. Check the number of stored programs, the ability to run two-point and multi-point calibration, and whether the analyzer can print or export results. Confirm that reagents are open, since proprietary reagents on a semi-automatic platform usually negate the cost advantage.
Full specifications
| Wavelength selection | 340–800 nm, 7 filters or monochromator |
|---|---|
| Assay programs | Up to 200 user-defined programs |
| Sample volume | 5–50 µL programmable |
| Reagent volume | 200–1000 µL programmable |
| Calibration | Factor, one-point and multi-point from stored calibrators |
| Temperature control | 25, 30 and 37 °C selectable |
| Reading interval | 1–120 s adjustable |
| Data output | Thermal printer, USB export, RS-232 |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Clinics using locally sourced reagents
- Assays not available as proprietary kits
- Veterinary and agricultural biochemistry
- Custom methods in research laboratories
Key features
- User-programmable assay parameters stored under test codes
- Open reagent compatibility with third-party kits
- Adjustable reading intervals and calculation windows
- Wide filter set or monochromator for method flexibility
- Configurable concentration units and print formats
- Reaction curve printout for method documentation
Frequently asked questions about Semi-Automatic Biochemistry Analyzer with Open Reagent Channels
The laboratory is responsible. Validation typically covers precision, linearity, comparison with an established method or reference material, and verification of the reference interval. Documentation must be retained for accreditation, and each new reagent lot or supplier change should be checked before reporting patient results.
Most open platforms allow the unit to be defined per test program, for example milligrams per deciliter or millimoles per liter, and the conversion factor is entered once. Some also store alternative units so that reports can be switched without reprogramming, which helps when clinicians use different conventions.
Quality control results will usually drift or fail before patient results are affected, so controls are the main safeguard. If a lot is out of specification, the laboratory should stop reporting, document the failure, and resolve it with the supplier, keeping the reagent lot number and control data as evidence.
With manual pipetting and a flow-through cell, an experienced operator can complete roughly 60 to 120 tests per hour for simple endpoint assays, less for kinetic tests that need several readings. Daily capacity therefore depends on staffing, so these analyzers are usually chosen for workloads below about one hundred to two hundred tests per day.
A flow-through cell is a fixed optical cell that the sample is aspirated into and then rinsed out, which reduces consumable costs but requires thorough washing to avoid carryover. Disposable cuvettes are used once and discarded, which simplifies workflow and eliminates carryover risk at a higher cost per test.
Assays that need many timed readings, such as complex kinetic enzyme methods, and assays with aggressive reagents or short reaction windows, are poorly suited. High-volume panels, tests requiring automatic dilution and rerun, and assays with very low analyte concentrations needing high sensitivity are also better handled on a fully automatic platform.
Related models





Random-Access Fully Automatic Chemistry Analyzer with STAT Priority
带急诊优先的随机存取全自动生化分析仪
- CE (to be confirmed)
- +2
