Semi-Automatic Biochemistry Analyzer with Integrated Incubator
内置温育器的半自动生化分析仪
- SKU SEM-0003
- Semi-Automatic Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Incubation positions | 8–20 tubes of 10–12 mm diameter |
|---|---|
| Incubation temperature | 25, 30, 37 °C selectable |
| Temperature stability | ±0.1 °C at 37 °C |
| Timing range | 1 s to 99 min programmable |
| Wavelength range | 340–700 nm with 6 filters |
| Photometric range | 0–3.0 absorbance units |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP06
What is the Semi-Automatic Biochemistry Analyzer with Integrated Incubator?
This model includes a temperature-controlled incubation block for reaction tubes or cuvettes on the instrument itself, so that the reaction temperature is defined by the analyzer rather than by an external bath. It suits methods where incubation timing and temperature must be tightly controlled.
What is the Semi-Automatic Biochemistry Analyzer with Integrated Incubator?
This model includes a temperature-controlled incubation block for reaction tubes or cuvettes on the instrument itself, so that the reaction temperature is defined by the analyzer rather than by an external bath. It suits methods where incubation timing and temperature must be tightly controlled.
Overview
In this configuration the incubation block holds eight to twenty reaction tubes at a selectable temperature, usually 25, 30 or 37 degrees Celsius, with stability around 0.1 degrees Celsius. The operator prepares the reaction in a tube, incubates it for the programmed time with an audible or visual timer, then transfers the mixture to the measuring position. Some instruments combine incubation and reading in the same cell so that the reaction curve is followed without transfer, which reduces timing error. Advantages include independence from a water bath, reproducible timing and easier workflow when several tests run in parallel. Limitations are that the operator still controls each step manually, so the platform suits low to moderate volumes and methods where the reaction does not need very frequent reads.
How does it work?
A semi-automatic analyzer contains a light source, a wavelength selector such as interference filters or a grating, a temperature-controlled measuring position and a photodetector. The operator pipettes a measured volume of sample and working reagent into a cuvette or into a flow-through cell, mixes, and starts the reading. The instrument records absorbance at one or more wavelengths at fixed intervals, applies endpoint, kinetic or fixed-time calculation according to the selected program, and converts the signal into concentration using a stored calibration curve. Because the reaction temperature strongly affects enzyme kinetics, the measuring position is held at 37 degrees Celsius or at another programmed temperature, usually within 0.1 degrees Celsius. The operator's pipetting technique, cuvette cleanliness and correct reagent preparation determine the quality of the result, which is why training and written procedures matter more on this platform than on a fully automatic analyzer.
What are the key features?
- Built-in incubation block holding 8 to 20 reaction tubes
- Selectable temperatures of 25, 30 or 37 °C
- Programmable incubation timer with audible alert
- Alternative configuration reading the cuvette during incubation
- Temperature stability within 0.1 °C in the block
- Reduced dependence on an external water bath
What are the technical specifications?
A typical semi-automatic biochemistry analyzer with integrated incubator configuration offers incubation positions of 8–20 tubes of 10–12 mm diameter, incubation temperature of 25, 30, 37 °C selectable, temperature stability of ±0.1 °C at 37 °C, timing range of 1 s to 99 min programmable, wavelength range of 340–700 nm with 6 filters and photometric range of 0–3.0 absorbance units. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Semi-Automatic Biochemistry Analyzer with Integrated Incubator is used in enzyme assays requiring strict timing, immunoturbidimetric assays in small batches, clinics without a separate water bath and teaching laboratories demonstrating assay kinetics. Across the wider Semi-Automatic Analyzers class, laboratories also deploy it for low-volume clinical chemistry testing, rural and outreach clinics and veterinary biochemistry.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP06, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a level bench away from draughts, direct sunlight and vibration, with a stable power supply and a grounded outlet. Verify performance at installation with a reference material or an assigned sample, and check the temperature of the measuring position with an external thermometer. Daily work should include a distilled water blank, a control sample at normal and abnormal levels, and cleaning of the flow cell or cuvette holder. Replace lamps at the end of their rated life or when the blank absorbance rises, keep filters clean and dry, and store reagents according to the label. The laboratory must document operator competence, since results depend on pipetting accuracy, and should review calibration at each new reagent lot.
How do I select the right Semi-Automatic Biochemistry Analyzer with Integrated Incubator?
Specify this variant when timing and temperature reproducibility are critical, for example for enzyme assays with short linear windows, or when the laboratory wants to eliminate a water bath. In the RFQ confirm the number and diameter of incubation positions, the temperature accuracy and uniformity across the block, the timer resolution, and whether reading during incubation is supported.
How does it compare with other Semi-Automatic Analyzers variants?
Choose a semi-automatic analyzer when the budget is limited, when fewer than about one hundred tests are performed per day, or when the reagent menu changes often and single-channel flexibility is valuable. Compare models by the wavelength range and filter set, whether they use a flow-through cell or single cuvettes, the temperature control accuracy, and the calculation modes supported. A flow-through cell reduces cuvette cost but needs careful cleaning between samples to avoid carryover, while disposable cuvettes simplify workflow at higher consumable cost. Check the number of stored programs, the ability to run two-point and multi-point calibration, and whether the analyzer can print or export results. Confirm that reagents are open, since proprietary reagents on a semi-automatic platform usually negate the cost advantage.
Full specifications
| Incubation positions | 8–20 tubes of 10–12 mm diameter |
|---|---|
| Incubation temperature | 25, 30, 37 °C selectable |
| Temperature stability | ±0.1 °C at 37 °C |
| Timing range | 1 s to 99 min programmable |
| Wavelength range | 340–700 nm with 6 filters |
| Photometric range | 0–3.0 absorbance units |
| Calibration modes | One-point, two-point and kinetic factor |
| Interfaces | RS-232, USB, printer output |
| Power supply | AC 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Enzyme assays requiring strict timing
- Immunoturbidimetric assays in small batches
- Clinics without a separate water bath
- Teaching laboratories demonstrating assay kinetics
Key features
- Built-in incubation block holding 8 to 20 reaction tubes
- Selectable temperatures of 25, 30 or 37 °C
- Programmable incubation timer with audible alert
- Alternative configuration reading the cuvette during incubation
- Temperature stability within 0.1 °C in the block
- Reduced dependence on an external water bath
Frequently asked questions about Semi-Automatic Biochemistry Analyzer with Integrated Incubator
Peltier or dry-block incubators can hold temperature within about 0.1 degrees Celsius and avoid the contamination and evaporation issues of a water bath. Water baths transfer heat faster, which matters for large volumes, but a dry block is easier to maintain and monitor in a small laboratory.
Yes, if they share the same incubation temperature, which is a common reason for choosing a block with eight or more positions. Assays needing different temperatures must be run sequentially, so the laboratory should group its menu by temperature during method planning.
Verify with a calibrated electronic thermometer placed in a tube of water or in a temperature probe well, checking the set point and uniformity across the block at least annually, and after any service that affects the heating element. Record the values and the thermometer certificate in the maintenance file.
With manual pipetting and a flow-through cell, an experienced operator can complete roughly 60 to 120 tests per hour for simple endpoint assays, less for kinetic tests that need several readings. Daily capacity therefore depends on staffing, so these analyzers are usually chosen for workloads below about one hundred to two hundred tests per day.
A flow-through cell is a fixed optical cell that the sample is aspirated into and then rinsed out, which reduces consumable costs but requires thorough washing to avoid carryover. Disposable cuvettes are used once and discarded, which simplifies workflow and eliminates carryover risk at a higher cost per test.
Assays that need many timed readings, such as complex kinetic enzyme methods, and assays with aggressive reagents or short reaction windows, are poorly suited. High-volume panels, tests requiring automatic dilution and rerun, and assays with very low analyte concentrations needing high sensitivity are also better handled on a fully automatic platform.