Skip to main content
Lab Manufacturers China
Random-Access Fully Automatic Chemistry Analyzer with STAT Priority — product photo

Random-Access Fully Automatic Chemistry Analyzer with STAT Priority

带急诊优先的随机存取全自动生化分析仪

  • SKU FAA-0003
  • Fully Automatic Analyzers
  • CE (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)
  • NMPA class II registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Throughput300–600 tests/h photometric
First-result time4–10 min from aspiration
STAT positions5–10 priority sample positions
Sample positions80 positions with continuous loading
Test selectionUp to 45 tests per sample in one run
Reagent positions45 refrigerated positions
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP06

What is the Random-Access Fully Automatic Chemistry Analyzer with STAT Priority?

This analyzer accepts any combination of tests in any order, inserts emergency samples immediately and reports the first result within a few minutes. It suits hospital laboratories where inpatient, outpatient and emergency work share one instrument around the clock.

What is the Random-Access Fully Automatic Chemistry Analyzer with STAT Priority?

This analyzer accepts any combination of tests in any order, inserts emergency samples immediately and reports the first result within a few minutes. It suits hospital laboratories where inpatient, outpatient and emergency work share one instrument around the clock.

Overview

Random access means that every sample position can run a different test combination without batching, and the software schedules the reaction rotor to avoid reagent cross-contamination between adjacent tests. STAT samples are loaded into a priority position or a dedicated tube, and the scheduler advances them ahead of routine work. First-result time is typically four to ten minutes from aspiration, which is the parameter that matters most for emergency departments. Short turnaround is supported by pre-warmed reagents, optimized washing between reagent additions and photometric reading at short intervals. Some instruments also offer STAT panels with predefined test combinations for chest pain, sepsis or metabolic emergencies, and the software can send results to the LIS immediately after quality control acceptance, with subsequent amendments flagged.

How does it work?

A fully automatic analyzer moves tubes from a sample tray or rack to an aspiration station, where a probe with liquid-level and clot detection withdraws a measured volume. Reagent probes add the programmed volumes from refrigerated reagent positions, and the mixture is delivered into a reaction cuvette on a thermostatted rotor held at 37 degrees Celsius. A photometer with interference filters or a diffraction grating reads absorbance at several wavelengths, and the software applies the programmed calculation mode, converts the signal into concentration using the calibration curve and flags results that fall outside the linear range. Automatic dilution and rerun, carryover-free cuvette washing, onboard quality control with Levey-Jennings charts, and reagent inventory tracking are standard. Sample and reagent barcodes, patient demographics and test orders pass between the analyzer and the laboratory information system through HL7 or ASTM interfaces.

What are the key features?

  • Continuous random access with no batching requirement
  • STAT samples inserted ahead of routine workload
  • First-result time of 4 to 10 minutes
  • Predefined emergency panels for chest pain and sepsis
  • Scheduler that prevents reagent cross-contamination
  • Automatic transmission of accepted results to the LIS

What are the technical specifications?

A typical random-access fully automatic chemistry analyzer with stat priority configuration offers throughput of 300–600 tests/h photometric, first-result time of 4–10 min from aspiration, STAT positions of 5–10 priority sample positions, sample positions of 80 positions with continuous loading, test selection of Up to 45 tests per sample in one run and reagent positions of 45 refrigerated positions. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Random-Access Fully Automatic Chemistry Analyzer with STAT Priority is used in emergency department biochemistry, inpatient ward urgent testing, critical care and intensive care units and outpatient clinics with same-visit results. Across the wider Fully Automatic Analyzers class, laboratories also deploy it for hospital routine and emergency chemistry, metabolic, liver, kidney and lipid panels and specific protein measurement by immunoturbidimetry.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP06, CLSI EP07, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

The analyzer needs a stable, level floor or bench with adequate load capacity, a dedicated grounded power supply, controlled temperature and humidity, and purified water of consistent quality. Verify performance at installation with precision, linearity, carryover and method comparison studies following CLSI protocols, and validate the reference intervals against the local population. Daily tasks include checking water quality, reagents and waste, running two or three levels of control and reviewing the calibration status. Weekly and monthly maintenance covers probe cleaning, cuvette washing efficiency and photometer checks, and lamps, tubing and syringes are replaced on schedule. Instruments that handle patient samples must be decontaminated according to the manufacturer procedure before service, and all waste is treated as infectious.

How do I select the right Random-Access Fully Automatic Chemistry Analyzer with STAT Priority?

Specify this variant when emergency and routine work share one analyzer and turnaround time is a clinical priority. In the RFQ ask for the first-result time on your own STAT panel rather than for the headline figure, the number of priority positions, and the behaviour when several STAT samples arrive at once. Confirm that results can be transmitted immediately after quality control acceptance without manual release.

How does it compare with other Fully Automatic Analyzers variants?

Size the analyzer by daily and peak-hour test volume, then add thirty percent headroom for repeats and quality control. Determine whether you need open reagent channels for cost control or a closed system for convenience. Check the reaction cuvette type, because reusable cuvettes lower consumable cost but require a wash station, while disposable cuvettes simplify maintenance. Confirm the sample volume, which matters for pediatric work, and the reagent capacity per shift. Decide which integrated modules you need, such as ion-selective electrodes for sodium and potassium or immunoturbidimetry for specific proteins. Verify STAT access, first-result time, onboard water consumption and waste handling, LIS interface protocols, and the local availability of service, spare parts and application support before ordering.

Full specifications

Full specifications
Throughput300–600 tests/h photometric
First-result time4–10 min from aspiration
STAT positions5–10 priority sample positions
Sample positions80 positions with continuous loading
Test selectionUp to 45 tests per sample in one run
Reagent positions45 refrigerated positions
PanelsUser-definable cardiac, sepsis and metabolic panels
InterfacesLAN with HL7 or ASTM, two-way communication
Power supplyAC 220–240 V, 50/60 Hz with UPS recommendation

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Emergency department biochemistry
  • Inpatient ward urgent testing
  • Critical care and intensive care units
  • Outpatient clinics with same-visit results

Key features

  • Continuous random access with no batching requirement
  • STAT samples inserted ahead of routine workload
  • First-result time of 4 to 10 minutes
  • Predefined emergency panels for chest pain and sepsis
  • Scheduler that prevents reagent cross-contamination
  • Automatic transmission of accepted results to the LIS

Frequently asked questions about Random-Access Fully Automatic Chemistry Analyzer with STAT Priority

Four to ten minutes is typical, but the time depends on the panel, whether reagents need warming and whether a routine batch is already in the rotor. Ask the supplier to demonstrate the time for your specific STAT panel during an on-site evaluation rather than relying on the brochure figure.

Request a quotation for the Random-Access Fully Automatic Chemistry Analyzer with STAT Priority

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote