

Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module
带免疫比浊模块的全自动生化分析仪
- SKU FAA-0005
- Fully Automatic Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Immunoturbidimetry with latex enhancement |
|---|---|
| Wavelengths | 340 nm and 550–600 nm selectable |
| Reaction time | 5–10 min per assay |
| CRP measuring range | 0.5–300 mg/L with dilution |
| Calibration | Multi-point, 5 to 6 levels, lot-specific |
| Antibody reagent storage | 2–8 °C refrigerated onboard |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP06
What is the Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module?
This analyzer integrates immunoturbidimetric detection for specific proteins such as CRP, immunoglobulins and transferrin, so that protein assays run alongside routine chemistry. It suits laboratories consolidating immunoassay work onto a chemistry platform.
What is the Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module?
This analyzer integrates immunoturbidimetric detection for specific proteins such as CRP, immunoglobulins and transferrin, so that protein assays run alongside routine chemistry. It suits laboratories consolidating immunoassay work onto a chemistry platform.
Overview
Immunoturbidimetry measures the light scattered or absorbed by antigen-antibody complexes that form when reagent antibody is added to the sample. The increase in turbidity is proportional to analyte concentration over a defined range and is read at a wavelength such as 340 or 550 nanometers. The analyzer schedules these assays with an initial sample blank and often with an antigen-excess check, because very high concentrations can cause a paradoxical fall in signal. Reaction times are longer than for simple colorimetric tests, typically five to ten minutes, which affects effective throughput. Antibody reagents must be stored refrigerated and used within their stability period, and calibration curves are run with multi-point calibrators. Common analytes include CRP, immunoglobulins A, G and M, transferrin, apolipoproteins, rheumatoid factor and HbA1c.
How does it work?
A fully automatic analyzer moves tubes from a sample tray or rack to an aspiration station, where a probe with liquid-level and clot detection withdraws a measured volume. Reagent probes add the programmed volumes from refrigerated reagent positions, and the mixture is delivered into a reaction cuvette on a thermostatted rotor held at 37 degrees Celsius. A photometer with interference filters or a diffraction grating reads absorbance at several wavelengths, and the software applies the programmed calculation mode, converts the signal into concentration using the calibration curve and flags results that fall outside the linear range. Automatic dilution and rerun, carryover-free cuvette washing, onboard quality control with Levey-Jennings charts, and reagent inventory tracking are standard. Sample and reagent barcodes, patient demographics and test orders pass between the analyzer and the laboratory information system through HL7 or ASTM interfaces.
What are the key features?
- Turbidimetric reading of antigen-antibody complexes at dedicated wavelengths
- Sample blank for each measurement to correct sample turbidity
- Antigen excess check for high-concentration samples
- Multi-point calibration with refrigerated antibody reagents
- Longer reaction windows for latex-enhanced assays
- Combined report with routine chemistry from the same sample
What are the technical specifications?
A typical fully automatic chemistry analyzer with immunoturbidimetry module configuration offers measurement principle of Immunoturbidimetry with latex enhancement, wavelengths of 340 nm and 550–600 nm selectable, reaction time of 5–10 min per assay, CRP measuring range of 0.5–300 mg/L with dilution, calibration of Multi-point, 5 to 6 levels, lot-specific and antibody reagent storage of 2–8 °C refrigerated onboard. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module is used in inflammation monitoring with CRP, immunoglobulin measurement in immunology, nutritional and apolipoprotein testing and diabetes monitoring with HbA1c. Across the wider Fully Automatic Analyzers class, laboratories also deploy it for hospital routine and emergency chemistry, metabolic, liver, kidney and lipid panels and specific protein measurement by immunoturbidimetry.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP06, CLSI EP07, CLSI C24, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
The analyzer needs a stable, level floor or bench with adequate load capacity, a dedicated grounded power supply, controlled temperature and humidity, and purified water of consistent quality. Verify performance at installation with precision, linearity, carryover and method comparison studies following CLSI protocols, and validate the reference intervals against the local population. Daily tasks include checking water quality, reagents and waste, running two or three levels of control and reviewing the calibration status. Weekly and monthly maintenance covers probe cleaning, cuvette washing efficiency and photometer checks, and lamps, tubing and syringes are replaced on schedule. Instruments that handle patient samples must be decontaminated according to the manufacturer procedure before service, and all waste is treated as infectious.
How do I select the right Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module?
Add immunoturbidimetry when specific proteins are requested frequently and consolidating them reduces sample handling and cost. In the RFQ confirm which analytes the module supports with validated parameters, the calibration frequency needed, and how the analyzer handles antigen excess. Note that reaction time reduces effective throughput, so plan capacity accordingly.
How does it compare with other Fully Automatic Analyzers variants?
Size the analyzer by daily and peak-hour test volume, then add thirty percent headroom for repeats and quality control. Determine whether you need open reagent channels for cost control or a closed system for convenience. Check the reaction cuvette type, because reusable cuvettes lower consumable cost but require a wash station, while disposable cuvettes simplify maintenance. Confirm the sample volume, which matters for pediatric work, and the reagent capacity per shift. Decide which integrated modules you need, such as ion-selective electrodes for sodium and potassium or immunoturbidimetry for specific proteins. Verify STAT access, first-result time, onboard water consumption and waste handling, LIS interface protocols, and the local availability of service, spare parts and application support before ordering.
Full specifications
| Measurement principle | Immunoturbidimetry with latex enhancement |
|---|---|
| Wavelengths | 340 nm and 550–600 nm selectable |
| Reaction time | 5–10 min per assay |
| CRP measuring range | 0.5–300 mg/L with dilution |
| Calibration | Multi-point, 5 to 6 levels, lot-specific |
| Antibody reagent storage | 2–8 °C refrigerated onboard |
| Sample blank | Automatic two-point blank subtraction |
| Effective throughput | Reduced by 20–40 % when turbidimetric assays dominate |
| Interfaces | Integrated with analyzer LIS interface |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Inflammation monitoring with CRP
- Immunoglobulin measurement in immunology
- Nutritional and apolipoprotein testing
- Diabetes monitoring with HbA1c
Key features
- Turbidimetric reading of antigen-antibody complexes at dedicated wavelengths
- Sample blank for each measurement to correct sample turbidity
- Antigen excess check for high-concentration samples
- Multi-point calibration with refrigerated antibody reagents
- Longer reaction windows for latex-enhanced assays
- Combined report with routine chemistry from the same sample
Frequently asked questions about Fully Automatic Chemistry Analyzer with Immunoturbidimetry Module
They use multi-point calibrators, usually five or six levels, and the curve is valid for a defined period or one reagent lot. Many assays require recalibration with each new antibody lot, and the laboratory should verify precision and carryover for these channels separately from the colorimetric menu.
At very high analyte concentrations the antibody becomes saturated, complexes become smaller, and turbidity falls, so the analyzer may report a falsely low result. Instruments detect this by comparing the reaction rate with a stored curve behaviour or by adding a check reagent, and the sample is then re-run at a dilution.
The optical cuvette and the reagent probes used for antibody reagents should be cleaned according to the manufacturer schedule, because protein build-up changes light scatter. Reagent lines serving latex reagents may also need periodic priming, and the reaction rotor wash efficiency should be verified when turbidimetric tests are run frequently.
Throughput is usually quoted as photometric tests per hour, and should be checked against the panel you actually run, because tests needing multiple reagent additions or long incubation reduce the effective rate. Also ask for the first-result time and the STAT insertion time, which matter more than peak throughput in emergency work.
An open system accepts reagents from any supplier once the channel parameters are programmed and validated, which lowers cost per test but places method validation with the laboratory. A closed system uses barcoded reagents from the platform supplier with presets, which simplifies operation and training.
Add the module when sodium, potassium, chloride or calcium are requested often enough to justify it, because it avoids a separate electrolyte analyzer and an extra sample tube. If electrolyte volume is low, or if blood gas analysis is already on site, a separate compact electrolyte analyzer may be more economical.
Related models



Random-Access Fully Automatic Chemistry Analyzer with STAT Priority
带急诊优先的随机存取全自动生化分析仪
- CE (to be confirmed)
- +2

Fully Automatic Chemistry Analyzer with Integrated ISE Module
带集成离子选择电极模块的全自动生化分析仪
- CE (to be confirmed)
- +2


