Ion-Selective Electrode Electrolyte Analyzer
离子选择电极电解质分析仪
- SKU EAN-0001
- Electrolyte Analyzers
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measured analytes | Na+, K+, Cl- with optional Ca2+ or Li+ |
|---|---|
| Measuring range Na+ | 90–180 mmol/L |
| Measuring range K+ | 1.0–10.0 mmol/L |
| Sample volume | 100–200 µL |
| Throughput | 60–120 samples/h |
| Calibration | Automatic two-point, every 2–4 h or per shift |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP15
What is the Ion-Selective Electrode Electrolyte Analyzer?
An ion-selective electrode electrolyte analyzer measures sodium, potassium, chloride and sometimes calcium from serum, plasma, whole blood or urine using the Nernstian response of selective membranes. It is the standard benchtop instrument for routine and urgent electrolyte testing.
What is the Ion-Selective Electrode Electrolyte Analyzer?
An ion-selective electrode electrolyte analyzer measures sodium, potassium, chloride and sometimes calcium from serum, plasma, whole blood or urine using the Nernstian response of selective membranes. It is the standard benchtop instrument for routine and urgent electrolyte testing.
Overview
The instrument contains a sample path that presents the sample to a set of electrodes and then to a reference electrode, with a peristaltic pump or syringe moving calibration standards, samples and cleaning solutions through the same line. Each electrode produces a potential that the analyzer converts into concentration after temperature correction and two-point calibration. Most models measure sodium, potassium and chloride as standard, and calcium or lithium electrodes are available options. Sample requirements are small, typically 100 to 200 microliters of serum or plasma, and the result is available in thirty to sixty seconds. Quality features include slope checking at each calibration, a blockage or clot alarm, and a standby mode that keeps the electrodes wet between runs.
How does it work?
An ion-selective electrode consists of a membrane that responds selectively to one ion, an internal filling solution and a reference electrode. When the sample contacts the membrane, a potential develops across it that follows the Nernst equation, changing by about 59 millivolts for a tenfold change in ion activity at 25 degrees Celsius. The analyzer measures this potential against the reference electrode, corrects for temperature, and calculates concentration from a two-point calibration with standard solutions of known activity. Direct measurement presents undiluted whole blood, plasma, serum or urine to the electrode, which is preferred for whole blood samples and for patients with abnormal protein or lipid content. Indirect measurement dilutes the sample with a reagent before the electrode, which suits diluted samples and automated high-throughput operation. Sodium, potassium, chloride, calcium, lithium and magnesium electrodes differ in membrane composition.
What are the key features?
- Sodium, potassium and chloride electrodes with optional calcium or lithium
- Two-point calibration with automatic slope checking
- Sample volume of 100 to 200 microliters per measurement
- Result available within 30 to 60 seconds
- Clot and blockage alarm on the sample path
- Standby mode keeping electrodes conditioned between runs
What are the technical specifications?
A typical ion-selective electrode electrolyte analyzer configuration offers measured analytes of Na+, K+, Cl- with optional Ca2+ or Li+, measuring range Na+ of 90–180 mmol/L, measuring range K+ of 1.0–10.0 mmol/L, sample volume of 100–200 µL, throughput of 60–120 samples/h and calibration of Automatic two-point, every 2–4 h or per shift. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ion-Selective Electrode Electrolyte Analyzer is used in routine serum electrolyte panels, emergency department electrolyte testing, pre-operative assessment and urine electrolyte measurement. Across the wider Electrolyte Analyzers class, laboratories also deploy it for critical care and emergency electrolyte testing, dialysis and renal unit monitoring and surgical and perioperative assessment.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP15, CLSI C29, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the analyzer on a level bench away from direct sunlight and heat sources, with a grounded power supply and enough space for reagent and waste containers. Verify performance at installation with aqueous standards and with split serum samples compared against another method, and check the slope of each electrode, which should fall within the expected Nernstian range. Daily tasks include calibration with the supplied standards, measurement of normal and abnormal control material, and inspection of the sample path for air bubbles, clots or protein deposits. Electrodes and tubing are replaced when slope, response time or precision deteriorates. Treat all blood samples as infectious, dispose of waste according to local rules, and record every maintenance action for accreditation.
How do I select the right Ion-Selective Electrode Electrolyte Analyzer?
Specify this variant when a compact dedicated instrument is needed for routine and urgent electrolytes. In the RFQ confirm the analytes included, whether measurement is direct or indirect, the calibration interval and the expected electrode life, and whether a urine mode is available. Ask for the slope range specification and the acceptance criteria used at calibration.
How does it compare with other Electrolyte Analyzers variants?
Choose an electrolyte analyzer when the electrolyte request volume justifies a dedicated instrument, typically more than thirty tests per day, or when whole blood electrolytes must be available within minutes. Decide first between direct and indirect measurement, since they give different reference intervals and cannot be combined in one report. Then check whether you need whole blood capability, urine mode, or additional analytes such as ionised calcium, lithium or magnesium. Compare calibration frequency and electrode life, because these drive running cost, and the sample volume, which matters for pediatric and neonatal work. Confirm that the instrument reports temperature-corrected results, that it has a clot detection or blockage alarm, and that results can be transmitted to the laboratory information system.
Full specifications
| Measured analytes | Na+, K+, Cl- with optional Ca2+ or Li+ |
|---|---|
| Measuring range Na+ | 90–180 mmol/L |
| Measuring range K+ | 1.0–10.0 mmol/L |
| Sample volume | 100–200 µL |
| Throughput | 60–120 samples/h |
| Calibration | Automatic two-point, every 2–4 h or per shift |
| Sample types | Serum, plasma, whole blood, urine |
| Display and printer | LCD with built-in thermal printer |
| Interfaces | RS-232, USB, LAN with LIS option |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Routine serum electrolyte panels
- Emergency department electrolyte testing
- Pre-operative assessment
- Urine electrolyte measurement
Key features
- Sodium, potassium and chloride electrodes with optional calcium or lithium
- Two-point calibration with automatic slope checking
- Sample volume of 100 to 200 microliters per measurement
- Result available within 30 to 60 seconds
- Clot and blockage alarm on the sample path
- Standby mode keeping electrodes conditioned between runs
Frequently asked questions about Ion-Selective Electrode Electrolyte Analyzer
Most instruments calibrate automatically every two to four hours and after each electrode change or long standby period. Because calibration consumes standards, the frequency affects running cost, and laboratories should compare the calibration interval specification against their daily operating hours before choosing a model.
Use aqueous or serum-based controls at normal and abnormal levels, run at least once per shift or per day of reporting. Serum-based controls are preferable for validating the whole system, while aqueous controls are convenient for verifying electrode slope. Each change of electrode or tubing requires control re-verification.
Typical signs are a calibration slope below the specified range, unstable readings, slow response, or control results biased in one direction. Cleaning the membrane with the recommended solution may restore performance; otherwise the electrode should be replaced and the slope rechecked after calibration.
Direct measurement applies undiluted sample to the electrode, so results reflect ion activity in plasma water. Indirect measurement dilutes the sample first, so in patients with abnormal protein or lipid content the two methods differ. Laboratories must choose one method and use matching reference intervals throughout.
Typical life is three to twelve months, or a stated number of measurements, depending on analyte, workload and sample matrix. Replace an electrode when the calibration slope leaves the acceptable range, when response time lengthens or when precision degrades, and always recalibrate after replacement.
Many instruments include a urine mode with its own calibration and dilution protocol, which is needed because urine concentrations are much wider in range. The laboratory should validate linearity, recovery and carryover for urine and report results using urine-specific reference intervals rather than serum ones.