Seed Purity Analysis Table
种子纯度检验台
- SKU SEE-0001
- Seed Purity Equipment
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Illumination | LED, adjustable, shadow-free |
|---|---|
| Illuminance | 500–2000 lux at surface |
| Working surface | 800 × 500 mm or larger |
| Grid | Ruled, removable |
| Magnification | 2–4× lens or stereo option |
| Trays | Removable, multiple sizes |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISTA International Rules for Seed Testing (purity), AOSA Rules for Testing Seeds (purity), GB/T 3543.3 (purity analysis)
What is the Seed Purity Analysis Table?
A workbench with even lighting, a ruled grid and trays for separating and identifying seed fractions. It is the right choice for the reference purity analysis required to report results under seed testing rules.
What is the Seed Purity Analysis Table?
A workbench with even lighting, a ruled grid and trays for separating and identifying seed fractions. It is the right choice for the reference purity analysis required to report results under seed testing rules.
Overview
The purity analysis table provides a controlled workspace for the analyst. Even, shadow-free illumination from above and sometimes from behind makes small differences in colour and shape visible, and a ruled grid or template helps spread the working sample so that no particle is overlooked. Trays, dishes and a magnifier or stereo microscope support identification of pure seed, other crop seed, weed seed and inert matter, and each fraction is collected separately for weighing. The table may include a drawer for tools, a built-in balance platform and a stirrer or divider for taking the working sample. Ergonomics matter because purity analysis is time consuming: a comfortable height, adjustable lighting and no glare reduce fatigue and error. The work surface must be smooth and easy to clean so that fine seed does not lodge and contaminate the next sample, and lighting should be consistent between analysts and laboratories.
How does it work?
Purity work combines visual examination with mechanical separation. A purity analysis table provides even lighting, a ruled grid, trays and magnifiers so an analyst can identify each particle and weigh the fractions. Seed blowers separate particles by aerodynamic drag, since light chaff and empty seeds are lifted by an air stream at a lower speed than dense, sound seed. Indented cylinder separators trap seeds in pockets according to their length and shape, lifting round or short seeds away from long ones. Electrostatic separators charge seed surfaces and separate those that hold a charge from those that conduct it away, which is useful for removing discoloured, damaged or coated seed. Sieve sets classify by width and thickness, and precision sieves prepare defined size fractions. Together these tools reduce a working sample to fractions that can be weighed and expressed as percentages.
What are the key features?
- Even, shadow-free lighting reveals small colour and shape differences.
- Ruled grid or template spreads the working sample for complete inspection.
- Removable trays and dishes collect each fraction for weighing.
- Magnifier or stereo microscope mount aids difficult identifications.
- Smooth, cleanable surface prevents carry-over between samples.
- Ergonomic height and adjustable lighting reduce analyst fatigue.
What are the technical specifications?
A typical seed purity analysis table configuration offers illumination of LED, adjustable, shadow-free, illuminance of 500–2000 lux at surface, working surface of 800 × 500 mm or larger, grid of Ruled, removable, magnification of 2–4× lens or stereo option and trays of Removable, multiple sizes. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Seed Purity Analysis Table is used in purity analysis for certification, weed seed identification, seed lot quality testing and training and reference work. Across the wider Seed Purity Equipment class, laboratories also deploy it for seed purity certification testing, seed lot cleaning and upgrading and weed seed contamination checks.
Which standards and certifications apply?
Relevant standards and methods include ISTA International Rules for Seed Testing (purity), AOSA Rules for Testing Seeds (purity), GB/T 3543.3 (purity analysis), ISO 520 (1000-grain mass) and ISTA Rules (other seed determination). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Take the working sample from the submitted sample by proper dividing, because purity results depend on the sample being representative. Follow the rule-defined masses and the order of separation for each species, and work methodically through the fractions so that nothing is lost or double-counted. Keep the purity table clean and the lighting consistent, and use magnifiers or a stereo microscope for difficult identifications. Calibrate and level the balance, and weigh each fraction to the resolution the rules require. Clean sieves, blowers and separators thoroughly between samples to avoid carry-over of small weed seeds, which is a major source of error. Retain fractions or photographs for verification, record species, method and operator, and store the working sample so results can be checked later.
How do I select the right Seed Purity Analysis Table?
Select the purity table as the core workstation for any laboratory that reports purity results. Add a blower, sieve set and separator to handle different fractions efficiently. In an RFQ, specify surface size, illumination, magnification and tray requirements.
How does it compare with other Seed Purity Equipment variants?
Choose equipment based on the species, the fraction to be separated and the volume of work. For the reference purity analysis that produces the reported percentages, the essential tools are an adequately lit purity table, sieves of the required apertures, a blower for chaff and light fractions, and a balance of suitable resolution; almost every laboratory needs these. Indented cylinder separators are added when slender or round seeds must be removed and for cleaning seed lots. Electrostatic separators are selected for removing discoloured, immature or damaged seed of the same size as good seed. Confirm that the working sample mass and sieve apertures match the species requirements in the applicable rules, and that cleaning between samples is practical. Also check the resolution and calibration schedule of the balance, since purity results depend on accurate weighing of each fraction.
Full specifications
| Illumination | LED, adjustable, shadow-free |
|---|---|
| Illuminance | 500–2000 lux at surface |
| Working surface | 800 × 500 mm or larger |
| Grid | Ruled, removable |
| Magnification | 2–4× lens or stereo option |
| Trays | Removable, multiple sizes |
| Balance platform | Integrated or adjacent |
| Surface material | Smooth laminate or stainless steel |
| Power supply | 220 VAC, 50 Hz |
| Operating temperature | 15–30 °C |
| Accessories | Forceps, spatulas, dividers |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Purity analysis for certification
- Weed seed identification
- Seed lot quality testing
- Training and reference work
Key features
- Even, shadow-free lighting reveals small colour and shape differences.
- Ruled grid or template spreads the working sample for complete inspection.
- Removable trays and dishes collect each fraction for weighing.
- Magnifier or stereo microscope mount aids difficult identifications.
- Smooth, cleanable surface prevents carry-over between samples.
- Ergonomic height and adjustable lighting reduce analyst fatigue.
Frequently asked questions about Seed Purity Analysis Table
Differences between pure seed and similar weed or crop seed are often subtle, such as colour, surface texture or small shape features. Even, shadow-free illumination of adequate intensity makes these visible and consistent, reducing misclassification.
The mass depends on the species and is set by the seed testing rules, typically from a few grams for small seeds to several hundred grams for large ones. It must be taken by proper dividing so that it represents the submitted sample.
Yes. The same even lighting and clean surface are useful for seedling evaluations and for other seed determination, so many laboratories use a single well-lit bench for several tasks, provided it is cleaned between uses.
The working sample is separated into pure seed of the test species, other crop seed, weed seed and inert matter, and each fraction is weighed and expressed as a percentage. The fractions must total one hundred percent within the tolerance set by the rules.
An air stream lifts light particles, empty seeds and chaff while dense, sound seed stays in the container. By adjusting the airflow, the operator removes the light fraction in a controlled and repeatable way, reducing manual work before visual examination.
It is used when seeds must be separated by length or roundness, for example removing round weed seeds from wheat or separating broken grains. Pockets of a defined diameter capture matching seeds and lift them out of the main flow.
Related models