Rubber Process Analyzer for Compound Characterization

胶料表征用橡胶加工分析仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature rangeAmbient to 200 °C
Temperature accuracy±0.3 °C
Strain range0.1–50%
Frequency range0.01–20 Hz
Torque range0–200 dN·m
Specimen volumeAbout 4.5 cm³
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D6204, ASTM D6601, ASTM D5289

What is the Rubber Process Analyzer for Compound Characterization?

A general-purpose rubber process analyzer performs cure tests, strain sweeps and frequency sweeps on one sealed specimen. It is the standard workhorse for relating compound composition to mixing quality and shaping behaviour.

What is the Rubber Process Analyzer for Compound Characterization?

A general-purpose rubber process analyzer performs cure tests, strain sweeps and frequency sweeps on one sealed specimen. It is the standard workhorse for relating compound composition to mixing quality and shaping behaviour.

Overview

The cavity is sealed between two dies with controlled closing force, one die oscillating at a programmed strain and frequency while the other measures reaction torque. Typical operation covers strains from about 0.1% to 50%, frequencies from 0.01 to 20 Hz and temperatures from ambient to 200 °C, which allows both uncured processability testing and cure testing without changing the specimen. Software reports elastic and viscous torque, tangent of the phase angle and complex modulus, and performs the temperature sweeps and superposition calculations needed for process correlation. A specimen volume of about 4.5 cm³ is usual, and the biconical die geometry gives an approximately uniform strain across the cavity so that results do not depend on where the specimen sat during closing.

How does it work?

A sealed, biconical cavity contains a specimen that is sheared by oscillation of one die while the reaction torque on the other die is measured. Because strain amplitude, frequency and temperature are all programmable, the same instrument can perform a cure test at production temperature, a strain sweep to quantify filler networking and a frequency sweep to describe viscoelastic response. Dynamic properties are reported as elastic and viscous torque or as complex modulus and phase angle, so the Payne effect, the influence of silane coupling agents on silica compounds and the effect of process oils can all be observed on one specimen. Cavity pressure is monitored to exclude blowing or volatile effects, and results are used both for compound development and for on-line release decisions in mixing plants.

What are the key features?

  • Programmable strain from 0.1% to 50%
  • Frequency range from 0.01 to 20 Hz
  • Temperature range to 200 °C with fast recovery
  • Elastic and viscous torque reporting
  • Cure, strain sweep and frequency sweep in one run
  • Biconical die for uniform strain distribution

What are the technical specifications?

A typical rubber process analyzer for compound characterization configuration offers temperature range of Ambient to 200 °C, temperature accuracy of ±0.3 °C, strain range of 0.1–50%, frequency range of 0.01–20 Hz, torque range of 0–200 dN·m and specimen volume of About 4.5 cm³. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Rubber Process Analyzer for Compound Characterization is used in mix quality assessment of filled compounds, cure and dynamic testing on the same specimen, effect of process oil on dynamic properties and comparison of carbon black and silica systems. Across the wider Rubber Process Analyzers class, laboratories also deploy it for filler networking and coupling agent evaluation, mix quality control of silica and carbon black compounds and cure and dynamic property testing in one run.

Which standards and certifications apply?

Relevant standards and methods include ASTM D6204, ASTM D6601, ASTM D5289, ISO 6502-3, ISO 289-4 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Dose the cavity consistently, because the strain field and the measured torque depend on how completely the cavity is filled, and clean both dies after every specimen to prevent cured residue from changing the geometry. Verify cavity temperature with a calibrated probe at the test condition, and check pressure sealing before running compounds that release volatiles. Record strain, frequency, temperature and closing pressure with every curve, since results are only comparable within the same conditions. Reference compounds with known dynamic behaviour give the most meaningful periodic check, and the die surface and seal condition should be inspected at the same interval.

How do I select the right Rubber Process Analyzer for Compound Characterization?

Choose this configuration when the laboratory needs both cure and dynamic characterisation in one instrument and operates mainly with hydrocarbon rubber compounds. Confirm the strain and frequency ranges cover your filler studies and that the temperature range matches your cure conditions, and specify a reference compound for periodic verification.

How does it compare with other Rubber Process Analyzers variants?

Choose a process analyzer when cure parameters alone cannot explain observed mixing or shaping behaviour. A basic instrument with programmable strain, frequency and temperature covers most compounding laboratories; the decisive options are the maximum frequency, the strain range, the cavity pressure rating and the number of cavities. Where filled rubber networking must be followed in detail, a wide strain range and a low-frequency capability are essential. Multi-cavity instruments suit mixing plants that release many batches per shift. Instruments with high-temperature cavities and pressure control are needed for compounds containing blowing agents, and for silicone or peroxide-cured systems where volatile release matters.

Full specifications

Full specifications
Temperature rangeAmbient to 200 °C
Temperature accuracy±0.3 °C
Strain range0.1–50%
Frequency range0.01–20 Hz
Torque range0–200 dN·m
Specimen volumeAbout 4.5 cm³
Closing forceAbout 8 kN
Data outputElastic and viscous torque, moduli, curves

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Mix quality assessment of filled compounds
  • Cure and dynamic testing on the same specimen
  • Effect of process oil on dynamic properties
  • Comparison of carbon black and silica systems

Key features

  • Programmable strain from 0.1% to 50%
  • Frequency range from 0.01 to 20 Hz
  • Temperature range to 200 °C with fast recovery
  • Elastic and viscous torque reporting
  • Cure, strain sweep and frequency sweep in one run
  • Biconical die for uniform strain distribution

Frequently asked questions about Rubber Process Analyzer for Compound Characterization

About 4.5 cm³, which is a disc roughly 30 mm in diameter and 6 mm thick. Specimens are normally cut from a compression-moulded pad prepared from the mixed compound, so that the material is representative and free of air pockets before the cavity closes.