Roller Drum Bioreactor System
滚筒生物反应器系统
- SKU ROL-0004
- Roller Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- IEC 61010-2-010 safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Bottle capacity | 10–100+ bottles |
|---|---|
| Growth surface | approx. 2–50 m² depending on format |
| Drum surface | 1–10 m² per drum |
| Temperature control | 30–40 °C, within ±0.5 °C |
| CO2 control | 0–10% optional |
| Rotation speed | 0.1–2 rpm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-010, IEC 61326-1
What is the Roller Drum Bioreactor System?
A roller drum bioreactor holds multiple roller bottles or a large drum on a rotating frame with temperature control and optional perfusion, increasing adherent cell surface area for industrial vaccine and protein production.
What is the Roller Drum Bioreactor System?
A roller drum bioreactor holds multiple roller bottles or a large drum on a rotating frame with temperature control and optional perfusion, increasing adherent cell surface area for industrial vaccine and protein production.
Overview
The system rotates a drum or a stack of roller bottles within a temperature-controlled cabinet, often with CO2 control and the option to perfuse medium continuously so that nutrients are replenished and metabolites removed without interrupting rotation. Perfusion supports higher cell densities than batch operation, and medium is exchanged through a rotating seal or a side port, with spent medium collected for analysis. Capacity ranges from about 10 to more than 100 bottles, corresponding to tens of square metres of growth surface, and drums of 1–10 m² are used where a single contiguous surface is preferred. Because many bottles run in one cabinet, uniformity of gas and temperature distribution is important, and rotation speeds are selected to keep the medium film moving without creating foam or shear damage.
How does it work?
Rotating a cylindrical vessel slowly, usually 0.1–2 rpm, keeps a thin film of medium moving over the inner surface. Adherent cells attach to the wetted wall and are alternately submerged in medium and exposed to the gas phase as the bottle turns, which improves oxygen transfer compared with a static flask and distributes nutrients evenly. Suspension cells are kept gently in motion so they do not settle. For high-density processes the vessels are placed in a warm cabinet or an incubated roller apparatus that controls temperature and, in some designs, carbon dioxide. Cell yield scales with the internal surface area of the bottle, so a 1,700 cm² roller bottle provides the equivalent growth area of several T-flasks while using less medium. Shear stress remains low because the fluid motion is gentle.
What are the key features?
- Temperature-controlled cabinet with optional CO2 control
- Rotation of 10 to over 100 roller bottles or a large drum
- Optional perfusion for continuous medium exchange
- Rotating seal or side port for aseptic medium handling
- Growth surface from several to tens of square metres
- Integrated logging of temperature, speed and perfusion rate
What are the technical specifications?
A typical roller drum bioreactor system configuration offers bottle capacity of 10–100+ bottles, growth surface of approx. 2–50 m² depending on format, drum surface of 1–10 m² per drum, temperature control of 30–40 °C, within ±0.5 °C, CO2 control of 0–10% optional and rotation speed of 0.1–2 rpm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Roller Drum Bioreactor System is used in industrial vaccine production, large-scale recombinant protein manufacture, high-density adherent cell culture with perfusion and process scale-up and reproducibility studies. Across the wider Roller Systems class, laboratories also deploy it for vaccine production in adherent cell lines, recombinant protein expression scale-up and mesenchymal stem cell expansion.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-010, IEC 61326-1, ISO 14644-1, USP <1046> and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing, IEC 61010-1 safety and IEC 61010-2-010 safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the apparatus on a level surface, because uneven loading causes bottles to creep and can lead to breakage. Load bottles symmetrically and secure them with the supplied clamps or retaining rings. Medium volume should be about 10–20% of bottle capacity, enough for the film to cover the inner surface without splashing into the cap filter. Change medium or split cultures according to cell density, and let bottles warm to 37 °C before inoculation, since cold medium slows attachment. Clean the rollers and frame regularly to remove spilled medium, which otherwise attracts contamination. If the unit is used inside an incubator, confirm that its heat output does not disturb chamber temperature, and record speed settings and run times in batch documentation.
How do I select the right Roller Drum Bioreactor System?
Select a roller drum bioreactor for industrial-scale adherent culture where surface area, perfusion and documented control are required. Specify bottle or drum format, growth surface, temperature and CO2 range, perfusion capability and the level of data logging and process control provided.
How does it compare with other Roller Systems variants?
Choose by scale and control requirements. A basic roller apparatus with adjustable speed suits laboratories that use a separate CO2 incubator, while an incubated roller system with temperature and CO2 control reduces handling and improves reproducibility. Roller mixers provide gentle agitation for suspension cells in bottles or tubes rather than surface growth. For larger adherent processes, roller drum bioreactors and packed-bed or rotating wall vessels increase surface area further and can be integrated with perfusion. Decide on the number of positions, speed range and accuracy, vessel compatibility, motor type and whether CO2 control is required. Check that the apparatus fits your incubator or cabinet, that bottles are secured against slipping at higher speeds, and that the surface material is compatible with the cleaning and sterilisation method you use.
Full specifications
| Bottle capacity | 10–100+ bottles |
|---|---|
| Growth surface | approx. 2–50 m² depending on format |
| Drum surface | 1–10 m² per drum |
| Temperature control | 30–40 °C, within ±0.5 °C |
| CO2 control | 0–10% optional |
| Rotation speed | 0.1–2 rpm |
| Perfusion rate | 0.1–5 vessel volumes per day |
| Medium volume | 10–200 L total |
| Data logging | Temperature, CO2, speed and perfusion records |
| Dimensions (W x D x H) | approx. 1,800 x 900 x 1,600 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Industrial vaccine production
- Large-scale recombinant protein manufacture
- High-density adherent cell culture with perfusion
- Process scale-up and reproducibility studies
Key features
- Temperature-controlled cabinet with optional CO2 control
- Rotation of 10 to over 100 roller bottles or a large drum
- Optional perfusion for continuous medium exchange
- Rotating seal or side port for aseptic medium handling
- Growth surface from several to tens of square metres
- Integrated logging of temperature, speed and perfusion rate
Frequently asked questions about Roller Drum Bioreactor System
Continuous medium exchange replenishes nutrients and removes lactate and ammonia without interrupting rotation, allowing higher cell densities and longer production phases than batch operation. It also makes it possible to collect product continuously from the outflow.
Medium enters and leaves through a rotating seal or side port connected to sterile tubing and bags. Connectors are designed for aseptic operation, and the fluid path is sterilised before use and kept closed throughout the run.
If temperature or gas distribution varies, bottles in different positions grow at different rates, which reduces batch consistency. Fan-assisted circulation, shelf spacing and loading patterns should be validated against cell yield data.
A roller bottle has a large internal surface area in a small volume, so more cells can attach per millilitre of medium. Rotation also improves gas exchange and nutrient distribution, and handling one large vessel instead of many flasks reduces labour.
Most adherent cultures run at 0.1–1 rpm and suspension cultures at up to 2 rpm. The aim is a continuously moving medium film without splashing; higher speeds increase shear and can detach cells or wet the cap filter.
Only if the apparatus is used outside an incubator. Culture medium buffered with bicarbonate needs 5% CO2 to hold pH, so a basic apparatus must be placed in a CO2 incubator, while incubated models include the gas and temperature control themselves.