Single-Channel Potentiostat/Galvanostat
单通道电化学工作站
- SKU POT-0001
- Potentiostats
- CE (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Applied potential range | ±10 V |
|---|---|
| Potential resolution | 1 µV (setting), 12 µV (measurement) |
| Current ranges | 100 pA–1 A in decade steps |
| Current resolution | 0.1% of range |
| Compliance voltage | ±12–20 V |
| EIS frequency range | 10 µHz–1 MHz |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, ISO 17475, ISO 16773-1
What is the Single-Channel Potentiostat/Galvanostat?
A single-channel potentiostat/galvanostat controls one three-electrode cell with current ranges from picoamperes to amperes and built-in impedance capability. It is the standard instrument for voltammetry, corrosion studies and electrode characterisation in research and analytical laboratories.
What is the Single-Channel Potentiostat/Galvanostat?
A single-channel potentiostat/galvanostat controls one three-electrode cell with current ranges from picoamperes to amperes and built-in impedance capability. It is the standard instrument for voltammetry, corrosion studies and electrode characterisation in research and analytical laboratories.
Overview
The single-channel instrument provides one cell connection with a potential range of plus or minus 10 V and current ranges spanning roughly 100 picoamperes to 1 ampere in decade steps, selected automatically or manually. Potential resolution of a few microvolts and current resolution of about 0.1 percent of range are typical, with 16 to 24 bit conversion. Compliance voltage of plus or minus 12 to 20 V allows work in moderately resistive electrolytes. A built-in frequency response analyzer covers 10 microhertz to 1 megahertz for impedance measurements, and techniques include cyclic and linear sweep voltammetry, chronoamperometry, chronopotentiometry, differential pulse and square wave voltammetry, bulk electrolysis and galvanostatic cycling. Data acquisition of several hundred thousand points per second supports fast kinetics. The instrument connects by USB, LAN or GPIB and is controlled by software with technique editors, equivalent circuit fitting and export to spreadsheet formats.
How does it work?
Measurements use a three-electrode cell. The potentiostat applies a programmed potential between the working and counter electrodes, while a high-impedance input senses the reference electrode. A control amplifier continuously adjusts the cell current so the working electrode potential equals the set value, and a current-to-voltage converter measures that current across a selectable resistor, giving current ranges that can span twelve decades on one instrument. Compliance or output voltage, typically plus or minus 12 to 20 V, sets how much current can be delivered in high-resistance cells. In galvanostat mode the instrument controls current and monitors potential instead. A frequency response analyzer superimposes small-amplitude sine waves for impedance measurements over frequencies from microhertz to megahertz. Resolution is limited by the analog-to-digital converter and by noise from cables, stirring and the reference electrode, which is why shielded cells and a Faraday cage are common. Software controls the waveform, records data and fits the electrochemical model.
What are the key features?
- Potential range ±10 V with microvolt setting resolution
- Current ranges from 100 pA to 1 A in decade steps
- Built-in frequency response analyzer from 10 µHz to 1 MHz
- Compliance voltage of ±12 to 20 V for resistive electrolytes
- Technique library including voltammetry, pulse methods and galvanostatic cycling
- USB, LAN or GPIB control with equivalent circuit fitting software
What are the technical specifications?
A typical single-channel potentiostat/galvanostat configuration offers applied potential range of ±10 V, potential resolution of 1 µV (setting), 12 µV (measurement), current ranges of 100 pA–1 A in decade steps, current resolution of 0.1% of range, compliance voltage of ±12–20 V and EIS frequency range of 10 µHz–1 MHz. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Single-Channel Potentiostat/Galvanostat is used in corrosion and inhibitor studies, electrode material characterisation, battery and supercapacitor research, sensor and biosensor development and electrocatalysis and fuel cell testing. Across the wider Potentiostats class, laboratories also deploy it for corrosion and inhibitor evaluation, battery and supercapacitor testing and electrochemical sensor and biosensor development.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, ISO 17475, ISO 16773-1, ASTM G5, ASTM G61 and ASTM G71. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the instrument on a stable bench away from motors, pumps and switching power supplies, and connect the cell in a Faraday cage for low-current work. Use shielded cable and keep the reference electrode close to the working electrode to reduce uncompensated resistance; measure and compensate that resistance, especially in low-conductivity electrolytes. Verify performance with a dummy cell or a standard redox couple such as ferri-ferrocyanide before critical experiments. Grounding arrangements must avoid loops between the potentiostat, the cell and any peripheral equipment such as rotators, lamps or temperature baths. Calibrate the internal references annually, replace worn electrode leads and clips, and record the cell configuration, electrodes, reference type and scan parameters with each data set so results remain traceable.
How do I select the right Single-Channel Potentiostat/Galvanostat?
Select the single-channel instrument when one experiment runs at a time and a wide current range with impedance capability is needed. Add channels only when parallel cells are genuinely required. In an RFQ, specify current and potential ranges, compliance voltage, impedance frequency span, maximum data rate, technique list, software licence and electrode cable set.
How does it compare with other Potentiostats variants?
Choose the number of cells you must run at once, because multi-channel instruments cost less per channel than separate units and share one software licence. Then match current range and resolution to the application: corrosion and battery tests need amperes with moderate resolution, while microelectrode and sensor work needs picoampere resolution. Check the compliance voltage for high-resistance electrolytes, the impedance frequency range, the maximum data acquisition rate for fast kinetics, and whether the software includes the techniques you use, such as cyclic voltammetry, chronoamperometry, pulsed techniques, electrochemical impedance spectroscopy and galvanostatic cycling. Modular instruments allow later expansion. For field corrosion surveys, a portable USB unit connected to a laptop is often sufficient. Specify the cell, electrodes, cables and any booster or low-current module in an RFQ.
Full specifications
| Applied potential range | ±10 V |
|---|---|
| Potential resolution | 1 µV (setting), 12 µV (measurement) |
| Current ranges | 100 pA–1 A in decade steps |
| Current resolution | 0.1% of range |
| Compliance voltage | ±12–20 V |
| EIS frequency range | 10 µHz–1 MHz |
| ADC resolution | 16–24 bit |
| Maximum data rate | 200–500 k samples/s |
| Cell connections | 1 working, 1 counter, 1 reference, 1 sense |
| Interfaces | USB 2.0, LAN, optional GPIB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Corrosion and inhibitor studies
- Electrode material characterisation
- Battery and supercapacitor research
- Sensor and biosensor development
- Electrocatalysis and fuel cell testing
Key features
- Potential range ±10 V with microvolt setting resolution
- Current ranges from 100 pA to 1 A in decade steps
- Built-in frequency response analyzer from 10 µHz to 1 MHz
- Compliance voltage of ±12 to 20 V for resistive electrolytes
- Technique library including voltammetry, pulse methods and galvanostatic cycling
- USB, LAN or GPIB control with equivalent circuit fitting software
Frequently asked questions about Single-Channel Potentiostat/Galvanostat
Yes, if the current range reaches the ampere level and the software includes galvanostatic cycling and impedance. Corrosion work typically uses milliamperes and microamperes, while battery and supercapacitor testing needs higher currents and long-duration cycling, so check thermal stability under load.
Microelectrode work often produces currents in the picoampere to nanoampere range, so the lowest current range must resolve those values with low noise. Look for a specified resolution around 0.1 percent of range in the lowest decade and use a Faraday cage.
A booster extends current capability above a few amperes, which is needed for large-area electrodes, high-rate battery testing or industrial electrolysis cells. Booster modules add cost and require larger cables, so they should be justified by the specific test current rather than purchased as insurance.
A potentiostat controls the working electrode potential and measures current, which is used for voltammetry, corrosion and impedance work. A galvanostat controls current and measures potential, which is used for battery cycling and electrodeposition. Most laboratory instruments combine both modes in one unit.
Match the range to the largest and smallest currents in the experiment. Battery and corrosion studies may reach amperes, while microelectrodes and modified surfaces work in nanoamperes or picoamperes. Choose an instrument whose lowest range resolves the smallest current of interest without unacceptable noise.
At low currents, ambient electrical noise from mains wiring, lighting and computers can dominate the signal. A Faraday cage around the cell, together with shielded leads and a single defined ground point, reduces that noise so nanoampere and picoampere measurements become usable.